November 28, 2017
7082-151C
11
MT. VERNON E2 INSERT
-C
M. LED Color Coding Chart and Explanation
The number of flashes between pauses is per one second unless otherwise indicated.
WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Fire pot floor open.
Do NOT store fuel:
• Closer than required clearances to combustibles to
appliance
• Within space required for loading or ash removal.
LED
Color
No. of Flashes
between pauses Description
Notes
Green
Steady ON while
priming feed tube
(max time
2 min utes)
Feed Motor is running
continuously.
(priming the feed tube)
When priming the feed system and filling the fire pot, DO
NOT OVERFILL Fire pot FOR IGNITION
.
The appliance
will automatically go into start up following the prime func-
tion.
Green 1x every 2
seconds
Appliance is on standby
To start appliance, follow start up sequence.
Green Blinks Continu-
ously
Appliance is in the start
up/ignition sequence or in
shutdown.
During shut down, the blowers will shut off when the
exhaust temperature has cooled.
Green 1X
Stage 1: Low heat
BTU Range: 14,620 - 19,694 Average: 19,054
Green 2X
Stage 2: Med-Low heat
BTU Range: 22,102 - 23,506
Average: 22,735
Green 3X
Stage 3: Med heat
BTU Range: 30,778 - 32,680
Average: 31,603
Green 4X
Stage 4: Med-Hi heat
BTU Range: 38,576 - 42,914
Average: 40,665
Green 5X
Stage 5: Hi heat
BTU Range: 49,830 - 52,460
Average: 51,528
Amber Blinks Continu-
ously
Appliance is in the shut-
down sequence.
During shut down, the blowers will shut off when the
exhaust temperature has cooled.
Red
1X
Empty Hopper Alarm
This alarm is caused by the fire going out from lack of fuel.
Reset by turning to “OFF” then turn dial to desired setting.
Red
2X
Exhaust Probe Alarm
Failed component error. See troubleshoot ing section for
more information.
Red
4X
Missed Ignition
There are a total of 2 tries per ignition sequence. If after
2 tries there is no rise in exhaust temperature this error
will occur. See the troubleshooting section for addi tional
information.
Red
6X
Encoder Alarm
Failed Component Error: Exhaust Speed Sensor. See
troubleshooting guide
for more information
Red
8X
Exhaust Over
Temperature Alarm
See troubleshooting guide
for more information.