May 5, 2015
7036-188E
5
MT VERNON AE INSERT
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
• Installation & use of any damaged appliance.
• Modifi cation of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Operating appliance without legs attached (if supplied
with unit).
• Do NOT Overfi re
Or any such action that may cause a fi re hazard.
WARNING
Reciprocating Saw
Channel Locks
Hammer
Phillips
Screwdriver
Tape Measure
Plumb Line
1/4” Self-Tapping Screws
Framing Material
Hi-temp Caulking Material
Gloves
Safety Glasses
Framing Square
Electric Drill & Bits (1/4”)
Level
May also need:
Vent Support Straps
Venting Paint
Tools and building supplies normally required
for installation, unless installing into an existing
masonry fi replace:
C. Tools And Supplies Needed
B. Thermostat Wall Control Location
The thermostat wall control’s location will have some affect
on the appliance’s operation.
• Maximum wire length from appliance is 100 feet (30.48m)
continuous unspliced wire. Recommended 20 gauge wire,
solid copper
.
•
When located close to the appliance, it may require a
slightly higher temperature setting to keep the rest of the
house comfortable.
•
When located in an adjacent room or on a different fl oor
level, you will notice higher temperatures near the appli-
ance.
CAUTION
The wall control is an integral part of the appliance. No other
wall control or thermostat can be substituted.
D. Inspect Appliance and Components
•
Open the appliance and remove all the parts and articles
packed inside the Component Pack. Inspect all the parts
and glass for shipping damage.
• Report to your dealer any parts damaged in shipment.
•
All labels have been removed from the glass door.
• Plated surfaces have been wiped clean with a soft cloth,
if applicable.
•
Read all the instructions before starting the installation.
Follow these instructions carefully during the
installation to ensure maximum safety and benefi t.
•
Follow pipe manufacturer instructions for installation
and air clearance requirements.
WARNING
Risk of Fire
Damaged parts could impair safe operation.
Do NOT install damaged, incomplete or
substitute components.
300 Watt Igniters come
installed in brand new Mt.
Vernon AE units and are
for pellet fuel only. The
380 Watt Igniter is re-
quired for burning multi-grain fuels and is includ-
ed in the component pack. Multi-fuels include,
corn, sunfl ower seeds, and wheat.