background image

 1 

 

 

 

 

                     7036-187   

 

 

 

           January 29, 2014

NOTICE: DO NOT DISCARD THIS MANUAL

MT VERNON PELLET INSERT

ADVANCED ENERGY (AE)

Model(s):

MTVERNINSAE-MBK

MTVERNINSAE-PMH

MTVERNINSAE-CSB

O-T  L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Owner’s Manual

Operation & Care

INSTALLER: Leave this manual with party responsible for use and operation. 

OWNER: Retain this manual for future reference. 

Contact your dealer with questions on installation, operation, or service. 

 

HOT SURFACES! 

 

Glass and other surfaces are hot  

 

during operation AND cool down.  

Hot glass will cause burns.

• 

Do not touch glass until it is cooled

• 

NEVER allow children to touch glass

• 

Keep children away

• 

CAREFULLY SUPERVISE children in same room as 

fireplace.

• 

Alert children and adults to hazards of high temperatures

• 

High temperatures may ignite clothing or other 

flammable materials.

• 

Keep  clothing,  furniture,  draperies  and  other  flammable 

materials away.

 WARNING

If the information in these instruc-

tions is not followed exactly, a 

fire may result causing property 

damage, personal injury, or death.

 

•  Do not store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of 

this or any other appliance.

•  Do not overfire - If heater or chimney con

-

nector glows, you are overfiring. Overfiring 

will void your warranty.

•  Comply with all minimum clearances to 

combustibles as specified.  Failure to 

comply may cause house fire.

WARNING

CAUTION

Tested and approved for wood pellets, shelled field 

corn, wheat and black oil sunflower seeds. Burning of 

any other type of fuel voids your warranty.

NOTE

To obtain a French translation of this manual, please contact 

your dealer or visit www.quadrafire.com

Pour obtenir une traduction française de ce manuel, s’il vous 

plaît contacter votre revendeur ou visitez www.quadrafire.com

CAUTION

Check building codes prior to installation.

•  Installation MUST comply with local, regional, state and na

-

tional codes and regulations.

•  Consult local building, fire officials or authorities having juris

-

diction about restrictions, installation inspection, and permits.

Summary of Contents for MTVERNINSAE-MBK

Page 1: ...f the information in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids...

Page 2: ...nd operating instructions Contact local building or fire officials about restrictions and inspection in our area WARNING FOR MOBILE HOMES Do not install appliance in a sleeping room An outside combust...

Page 3: ...e 7 E General Operating Information 8 F Before Your First Fire 9 G Filling the Hopper with Fuel 9 H Starting Your First Fire 9 I Fire Characteristics Flame Height Adjustment 9 J Battery Back up System...

Page 4: ...ginal purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT...

Page 5: ...014 7036 187 5 MT VERNON AE INSERT R January 19 2011 7022 122 Page 55 Castile Pellet Insert 4021 645C 12 29 10 Page 2 of 2 WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY WARRANT...

Page 6: ...not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with unit Do NOT Overfire If appliance or chi...

Page 7: ...ed field corn other biomass fuels Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Stand...

Page 8: ...stored in a tight container to prevent it from absorbing moisture from damp or wet floors This will also prevent rodents from becoming a problem Do not store any pellet fuel within the clearance requi...

Page 9: ...k that the ash pan hopper and firebox are empty and then close the firebox door NOTICE The tip of thermocouple must be in contact with the inside end of the thermocouple cover or missed ignitions can...

Page 10: ...Recommended Battery 12 volt deep cycle battery i e marine or RV type A 12 volt battery cable is available through your local dealer 13 Volts 12 Volts 11 Volts Battery Below 10 Volts Figure 10 1 K Cle...

Page 11: ...be added As the fire builds the appliance will change to medium soft start mode The heating cycle begins 3 Heating Cycle Auto Man L ML M MH H There are two choices in the Automatic Manual menu of how...

Page 12: ...nected MAINTENANCE BURN This indicates the appliance is operating on battery backup prior to the auto clean The maintenance burn will keep the system from shutting down as the appliance will not autom...

Page 13: ...with black tails and is lazy 4 The flame height adjustment needs to be reduced or the firepot needs cleaning Heat exchanger or exhaust blower needs cleaning 5 Excessive smokey start up 5 Either the fi...

Page 14: ...tem It indicates if the system is running in automatic or manual cycle if it is turned on or off and where it is in the operating sequence a START UP Indicates that the appliance is in start up cycle...

Page 15: ...t work call your dealer E The Main Menu The menu is the heart of customizing the operation of the pellet appliance system to your personal liking The choices on this menu are 1 Set Comfort Level Tempe...

Page 16: ...you are burning a high ash fuel set the fuel selec tion to Utility Pellets When purchasing corn or wheat to burn in your appliance read the ingredient label very carefully Do NOT purchase fuel that c...

Page 17: ...per month then press the button under Set Next The highlight will move to the day of the month display Using the UP DOWN buttons select the current date then press Set Next The highlight will move to...

Page 18: ...s you to adjust the appliance to your specific elevation Press the UP DOWN buttons to select your elevation The message in the center will change between NORMAL and HIGH If you select HIGH it will rep...

Page 19: ...hopper lid and glass door are both closed 1 At the starting screen press MENU Function Buttons Buttons Up Down Wall Control for Reference 6 Press DONE twice or wait 15 sec onds for starting screen to...

Page 20: ...VICE RETRY ERROR LIST 1 If the appliance has stopped operat ing check the wall control screen If it is showing Min Firepot Temp the hopper has run out of fuel 2 Fill the hopper with fuel and press the...

Page 21: ...ll no longer automatically light See section G on page 21 Use only approved fire starting gel to start fire High burn rate is no longer available on battery back up Each level drops down one level i e...

Page 22: ...eference Maintenance Chart NOTICE These are recommendations Clean more frequently if you encounter heavy build up of ash at the recommended interval or you see soot coming from the vent Not properly c...

Page 23: ...r of appli ance Do NOT store flammable materials in the appliance s vicin ity Do NOT use gasoline lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this...

Page 24: ...be fully closed when finished 6 Cleaning Heat Exchanger Drop Tube Exhaust Frequency Monthly or every 1 ton of fuel aprx 50 bags By Homeowner NOTE There are heavy duty vacuum cleaners specifically desi...

Page 25: ...hose 1 2 inch 12 7mm in diameter and approximately 2 feet 607mm in length to your vacuum hose 3 Use a bottle brush and push the ash down to the bottom Remove the combustion exhaust blower and then va...

Page 26: ...eaned at least once a year or more often depending upon the quality of your fuel or if there is a lot of horizontal pipe sections Ash will build up more quickly in the horizontal sections 11 Preparing...

Page 27: ...build up exceeds the half way point in the firepot before it automatically cleans then the firepot is not being cleaned often enough Another symptom is if clinkers are adhering to the sides of the fi...

Page 28: ...Auger jammed feed motor bad Pull the feed system and inspect Clear jam and Press Retry MISSED IGNITION Igniter bad or poor harness connection Out of fuel or fuel is bridging in hopper Faulty firepot t...

Page 29: ...ace If it is not centered the latch is trapped between the baffle and side of the firebox instead of latching properly g The bottom of the latches will fit over the posts Push the top of the latch for...

Page 30: ...replace the side set the bottom in first Squeeze the latch in an open position Place the cast side into posi tion and then release the latch The latch hooks onto a bracket to hold the side in place Co...

Page 31: ...ctor is highly recommended to protect the electronics When describing the location of a component it is always AS YOU FACE THE FRONT OF THE APPLIANCE A Component Functions 1 Auto Clean Motor The auto...

Page 32: ...Thermocouple Drop Tube This thermocouple is located on the bottom of the drop tube on the right side and attached with a wing nut It turns the convection blower on and off varies the speed of the con...

Page 33: ...Baffle Ash Pan Firepot Thermocouple Thermocouple Cover Baffle Firepot Ash Pan Thermocouple and Thermocouple Cover Heat Exchanger Front Back Power Supply Control Board Convection Blower Drop Tube Low F...

Page 34: ...acturing Date Sept 2006 Ending Manufacturing Date Active Advanced Energy Pellet Insert MTVERNINSAE CSB MTVERNINSAE MBK MTVERNINSAE PMH MTVERNINSAE CWL Sept 2006 thru June 2011 Part number list on foll...

Page 35: ...7000 320 10 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Glass Assembly Side 1 Piece 5 7 8 in W x 9 in H Interchangeable 414 5380 Y Gasket Channel 3 Mm X 32 Field Cut to Si...

Page 36: ...Glass Assembly 21 W x 14 H 7034 007 Y Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y Tape Door Corner Field Cut to Size 1 Ft SRV7027 227 Y 19 7 Glass Retainer 7034 136 20 Ash Pan Door...

Page 37: ...00 714 Y 31 Control Board Assembly SRV7000 456 Y Fuse 15A Slow Iec Glass Pkg of 10 7000 491 10 Y 32 Convection Blower SRV7000 260 Y 33 Gasket Blower Convection 7000 329 34 Detent Pin Pre 00700201366 7...

Page 38: ...ket Firepot 7034 190 Y 39 6 Auto Clean Link Arm 7034 176 Y 39 7 Plow Weldment Auto Clean 7034 024 Y 39 8 Rail Auto Clean SRV7034 152 Y 39 9 Spring Pkg of 4 7000 513 4 Y 39 10 Hitch Pin Clip 3 32 Pkg o...

Page 39: ...Label If Fireplace Altered Matte Black 7036 018 Sienna Bronze 7036 019 Willow 7036 020 Mahogany 7036 021 Cleanout Tool 414 1140 Y Dvd Advanced Energy 7000 335 Paint Touch Up Matte Black 812 0910 Sien...

Page 40: ...ss Power Out Ac AC Current 7034 220 Y Wire Harness Power Out Dc DC Current 7034 221 Y Wire Harness Power Supply Receptacle SRV7034 233 Y Wire Harness Snap Disc 7034 193 Y Wire Harness Thermostat SRV70...

Page 41: ...it OAK 3 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Panel Set Gold 250 4660 Surround Std Panel w Nickel...

Page 42: ...42 7036 187 January 29 2014 MT VERNON AE INSERT E Homeowner s Notes...

Page 43: ...January 29 2014 7036 187 43 MT VERNON AE INSERT...

Page 44: ...ville WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This produ...

Reviews: