34
3-90-7003999
Quadra-Fire • Hudson Bay Installation Manual_R26 • 01/20
I. Blower Installation
KIT CONTENTS:
Blower; 2 female spade wire connectors.
TOOLS REQUIRED:
Powered screwdriver with a #2 Phillips
head bit.
The blower motor comes standard with two male spade
wire connectors. If your appliance has a different
connection, use the two female spade wire connectors
provided to modify the appliance wiring harness.
Figure 8.23 Blower Wiring Diagram
F = Female spade connector
M = Male spade connector
Figure 8.25 -
Disconnect power to the appliance. To access
the blower, open the door located on the front of the pedestal.
Remove the two screws holding the blower bracket in place.
F
M
F
F
Thermal Disk
Fan Assembly
BLK
BLK
GRN
WHT
BLK
F
M F
M
WHT
Fan Speed Control
BLK
BLK
Strain Relief Bushing
Power Cord (110 VAC)
Ground
WHT
BLK
Figure 8.26 -
Disconnect wires to the blower motor. Remove
the blower from the bracket.
Figure 8.27 -
Install the new blower by slipping grommets
over studs on the blower bracket. Reinstall the blower and
bracket. Connect the wires. Install screws. Restore power
to the appliance.