Quadra-Fire • Hudson Bay Installation Manual_R26 • 01/20
Step 5 -
Place the wall thimble cover over the pipe assembly
and slide the appliance
and vent assembly towards the wall,
carefully inserting the vent pipe into the vent
termination
cap assembly. It is important that the vent pipe extend into
the vent
termination cap a sufficient distance so as to result
in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the
connection between the vent pipe and the vent
termination
cap by attaching the two sheet metal strips extending from
the vent
termination cap assembly into the outer wall of
the vent pipe. Use the two sheet metal screws provided to
connect the strips to the pipe section (Figure
5.9).
Note:
The attachment from the vent pipe to the vent
termination
cap must be sealed with silicone.
Termination
caps
shall not be recessed into a wall or siding.
WALL THIMBLE
COVER
WALL THIMBLE
VINYL SIDING
STANDOFF WITH
SIDING BENEATH
REMOVED
SCREWS
BOLT HORIZONTAL
TOP TO VINYL
STANDOFF
SCREWS
APPLY SEALANT
TO ALL FOUR
SIDES
VINYL SIDING
Figure 5.8
FOLD STRAP
HERE
WALL THIMBLE COVER/CEILING
FIRESTOP AS REQUIRED BY
LOCAL JURISDICTION
1/4 in. (6mm)
STRAP
SHEET METAL SCREW
WALL
THIMBLE
Figure 5.9
Do NOT connect a pipe section to a termination cap
without using the telescoping flue section found on the
termination cap.
WARNING
!
Burn Risk.
•
Local codes may require installation of a
cap shield to prevent anything or anyone
from touching the hot cap.
WARNING
!
Fire Hazard, Exhaust Fume
Risk, Impaired Performance of
Appliance
• Ensure vent components are locked together correctly.
• Pipe may separate if not properly joined.
WARNING
!