background image

Page  26

7075-205B

October 12, 2015

Voyageur Grand

I.  Blower Cord Installation on Left Side

The blower cord is shipped to be installed on the right side 
of the appliance.  You may relocate the cord so it is on the 
left side. 

Overview:

 You are removing the power cord from the 

blower controls, re-routing the cord to the left side and re-
installing the power cord to the blower controls.  Refer to 
the exploded drawing on 

page 24.

 

1.  Remove contents from box being careful not to scratch or 

damage the cast trim pieces.

2. 

Lay surround pieces face down on a protected surface to 
prevent scratching

.

3.  Align the bosses on the top piece to the holes on the side 

pieces.  Secure the 3 pieces together.

4.  Attach the mounting brackets to the side pieces included with 

the kit.  

Figure 23.1.

5.  In order to get a tight seal for the surround, you must reposition 

a side shield.  There are two holes on the shield and it will come 
from the factory secured in the fi rst (left) hole.  Remove the 
shield and re-install using the second (right) hole. Figure 43.2.

5.  Position the trim on the appliance matching up the mounting 

brackets with the slots on the appliance.

6.  Attach the surround to the appliance 2 screws.  

DO NOT OVERTIGHTEN SCREWS - MAY DAMAGE 
PROCELAIN FINISH.

Included in Surround Kit:

  (2) side pieces, left and right; (1) 

l top piece; (1) fastener package.

Tools Needed: 

Powered 4 to 6 inches long Phillips head 

screw driver; pliers

H.  All Cast Surround Kit 

4 Mounting Brackets

Mounting 
Brackets

Attach to Appliance 

with Screws

Remove and Reposition 
Side Shield using Second 
Hole

Do not overtighten - may 
damage porcelain finish

Figure 23.1

Figure 23.2

1.  Swing the grille down to expose the 2 bolts, one 

at each end.  Remove the bolts and pull blower 
access assembly away from appliance and store 
away from your work area.

2.  Remove the 2 screws in the hold down bracket in 

front of the blower assembly.  You do not need to 
remove the blower from the hold down bracket.  

3.  Disconnect the 2 blower wires that are attached 

to the wire harness and pull the blower assembly 
away from the appliance.

Figure 23.3

Figure 23.4

Size:  1416 mm W x 762 mm H

Summary of Contents for GRAND-MBK-AU

Page 1: ... angle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 18 1 21 1 21 2 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Please specify ceiling pitch prior to ordering the ceiling plate Quadra Fire Voyageur Grand ACC wood burner s are tested and approved to the N Z National Environmental Standards GRAND MBK AU Voyageur ...

Page 2: ...mth and comfort of your hearth appliance Thank you for choosing Quadra Fire and Welcome to the Quadra Fire Family VOYAGEUR GRAND Serial No 007057 U S ENVIRONMENTAL PROTECTION AGENCY Export stove May not be operated within the United States DO NOT REMOVE THIS LABEL Mfg by 1445 N Highway Colville WA 99114 www quadrafire com Made in U S A of US and imported parts 7075 206 JAN FEB MAR APR MAY JUN JUL ...

Page 3: ...rances A Appliance Dimensions 16 B Clearances to Combustibles UL and ULC and Hearth Protection Requirements 17 C Alternate Floor Protection Calculation 18 Section 6 Chimney Systems A Venting Systems 19 B Inspections 19 C Larger Chimneys 19 D Masonry Chimney 19 E Prefabricated Metal Chimney 19 F Installation into a Masonry Fireplace 20 G Installation into a Factory Built Fireplace 20 Section 7 Appl...

Page 4: ...RN RATE CONTROL Upper Right Corner LOAD WOOD ADD NEWSPAPER ADD KINDLING ADD MORE WOOD SECURELY LATCH THE DOOR 4 LIGHT THE PAPER OPEN AIR CONTROLS REDUCE AIR CONTROL Set to desired heat output WARNING Risk Of Fire WARNING Risk Of Fire DO NOT LEAVE UNATTENDED During startup if additional draft is needed allow the door to remain open approxi mately1 2 inch Once the draft is established close and secu...

Page 5: ... burn rate instructions below and refer to Figure 5 1 NOTE These are guidelines Actual settings may vary with type of wood chimney draft altitude and other variables E Blower Control Box Snap Disc Operating Instructions 1 The blower will turn on off automatically when set to AUTO Figure 6 1 on page 6 2 When set to MANUAL the fan will turn on off only when you turn it on or off This setting over ri...

Page 6: ...n within close proxim ity approximately 4 ft 1 2m of appliance Can reverse air flow blowing hot air into appliance cavity Can damage appliance blower due to overheating 6 The blower is equipped with a rheostat speed control The highest blower speed is obtained by turning the rheostat on then adjusting back towards OFF as far as possible without turning the blower off For a low blower speed turn th...

Page 7: ...from the firebox It is also recommended that before each heating season the entire system be professionally inspected cleaned and repaired if necessary WARNING Risk of Fire Do not use chimney cleaners or flame colorants in your appliance It will corrode your pipe Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled ...

Page 8: ...he way open for 15 20 min utes should remove the built up coating E Glass Cleaning CAUTION Handle glass assembly with care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive cleaners Do not clean glass while it is hot Replace the firebrick if they become crumbly and or if there is a 1 4 inch 6 35mm gap between the bricks The firebox is lined with firebrick which has exce...

Page 9: ...bustible container Firebrick is designed to protect your firebox After ashes are removed inspect the fire brick and replace firebricks that are crum bling cracked or broken WEEKLY or After Every 25 Loads of Wood Keep door and glass gasket in good shape to maintain good burn times on a low burn setting To test place a dollar bill between the stove and door and then shut the door If you can pull the...

Page 10: ...ilding a Fire Section Check for adequate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire Section Flue blockage such as birds nests or leaves ...

Page 11: ... only be broken by impact or misuse WARNING Risk of Fire or Injury Use only glass that is specified in the manual DO NOT replace with any other material Glass breakage will occur CAUTION Handle glass with care Inspect the gasket to ensure it is undamaged Do NOT strike slam or scratch glass Do NOT operate appliance with glass door assembly removed Do NOT operate with glass cracked broken or scratch...

Page 12: ...old down bracket s screws are completely seated in the grom ments Insert the locating tab in the hold down bracket into the placement slot Shock Risk Do NOT remove grounding prong from plug Plug directly into properly grounded 3 prong receptacle Route cord away from appliance Do NOT route cord under or in front of appliance CAUTION Figure 8 1 Do NOT allow hot coals or embers to overflow ash lip Ma...

Page 13: ...e right side Remove the baffle boards and ceramic blanket together Figure 9 3 4 Re install in reverse order Be sure the baffle boards and ceramic blanket are in their proper positions E Door Handle Assembly 1 Install washer on door handle shaft 2 Slide door handle through door 3 Install additional washer s as shown in Figure 9 1 4 Install key in groove 5 Align groove in latch cam with key slide la...

Page 14: ...nutes before trying to remove them 4 Slide the tube channel assembly all the way to left until it is off the threads Drop the right side down then slide the assembly back to right Figure 10 3 5 The ceramic blanket and both baffle boards can be removed at the same time you remove the tube channel assembly 6 When the tube channel assembly is free of the left side support rotate clockwise and pull as...

Page 15: ...ntact your dealer if any irregularities are noticed 3 All safety warnings have been read and followed 4 This Owner s Manual has been read 5 Floor protection requirements have been met 6 Venting is properly installed per vent manufacturing instructions 7 The proper clearances from the appliance and chimney to combustible materials have been met 8 The masonry chimney is inspected by a professional a...

Page 16: ...rall Sizes A B Metal Surround w Cast Trim STD 1080 mm 762 mm Metal Surround w Cast Trim LRG 1219 mm 864 mm All Cast Surround 1016 mm 762 mm Metal Surround w Standard Trim STD 1092 mm 787 mm Metal Surround w Standard Trim LRG 1295 mm 2184 mm Figure 12 3 Side View With Optional Flue Adapter 32 5 8 829mm 23 3 4 602mm 17 15 16 456 mm 5 127mm 14 356mm 25 3 4 655mm 25 1 2 648mm 30 15 382mm 14 356mm 11 2...

Page 17: ...EQUIREMENT FIREPLACE FRONT SURFACE SIDE TRIM 3 max depth SIDE WALL MANTEL 12 max depth TOP TRIM 3 4 max depth MANTEL DEFLECTOR REQUIRED MINIMAL REQUIREMENT FOR EXTENSION PROTECTION THE HEARTH THERMAL PROTECTION MINIMAL REQUIREMENT IS A MINIMUM QUANTITY OF 2 15MM COMPRESSED CEMENT SHEETS STACKED ON TOP OF EACH OTHER WITH A THERMAL CONDUCTIVITY OF 0 5 W mÛK NOTE The fireplace is to be set on a non c...

Page 18: ...to AS NZS 2198 2001 3 2 3 B Clearances to Combustibles Cont d Required Protection Suggested Protection NOTE Keep Ashlip Clear of Ashes NOTE Clearances may only be reduced by means approved by the regulatory authority having juris diction Fire Risk Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING Figure 14 2 NOTE Hearth Rug may be used i...

Page 19: ...laceable for cleaning and re installation NOTE Refer to chimney liner manufacturer for recom mendations on supporting the liner Installation into fireplaces without a permit will void the listing A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be 152 mm minimum diameter stainless steel connector pipe Chimney The chimney can be new or existing masonry or pref...

Page 20: ...safety of your insert by directing the hot gases up the flue but will also help increase the unit s efficiency and decrease creosote deposits in the chimney When a connected flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created This great draft can decrease problems such as difficult start ups smoking out the door and dirty glass G Installation Into...

Page 21: ...Front of Smoke Chamber Damper Plate Removed or Fastened in Open Position Seal with Non Combustible Material Minimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in Chimney Combustible Floor Figure 17 1 Masonry Chimney with a Full Liner Kit Type NO...

Page 22: ...assembly 5 Remove the outside air cover plate B on outer can and dis card Figure 19 2 6 Install optional flex adapter to outer can with the same screws Do not use plastic wire ties that come with the kit as they will melt NOTE You may need to install the flex pipe into the firebox first depending on installation Attach flex to adapater with at least 2 screws 7 Ensure existing access hole in firepl...

Page 23: ...Re install the screws to secure in place D Leveling Legs B Optional Elbow Flue Adapter Installation Optional use of a Simpson Duravent 15 Universal Elbow Part Number 4615 may be purchased directly through your local Simpson Durvent Pipe Distributor or from your local Quadra Fire dealer Part Number DV 4615 Figure 20 1 shows a vertical installation and also how to create an optional 30 elbow install...

Page 24: ...iance top Secure in place Figure 21 2 7 Use the strain relief in the surround side for blower cord installation and use the cover plug to insert into the hole where the blower cord is not installed Figure 21 2 Corner Brackets Figure 21 3 E Securing Appliance to Stove Pipe Liner 1 Once you have the appliance in place and secured remove the tube channel assembly baffle board and ceramic blanket Deta...

Page 25: ...Powered 102 to 152 millimeters long Phillips head screw driver pliers G Standard Surround Cast Trim Kit 4 Felt Vibration Insulation Pads Secure Surrounds to Cast Trim Kit Attach Magnet before installing Cast Footers Magnet Installed Cast Footers Left Right Figure 22 1 Back of Side Piece Magnet Attached Faces Front Clearance Notch is facing the front Figure 22 2 7 Place the cast footers under the m...

Page 26: ...hole Remove the shield and re install using the second right hole Figure 43 2 5 Position the trim on the appliance matching up the mounting brackets with the slots on the appliance 6 Attach the surround to the appliance 2 screws DO NOT OVERTIGHTEN SCREWS MAY DAMAGE PROCELAIN FINISH Included in Surround Kit 2 side pieces left and right 1 l top piece 1 fastener package Tools Needed Powered 4 to 6 in...

Page 27: ...e the 2 screws at the top of the control plate Push the bottom of the control plate to the inside of the appliance and partially remove the control plate assembly White Wire Black Wire Figure 24 2 5 Locate the black and white wires that are part of the power cord and disconnect those wires from the wire harness Green Grounding Wire Remove Screw 6 Remove the screw that is holding the ground lug to ...

Page 28: ...Wire 11 Connect the white wire on the power cord into the fiber wrapped wire on the wire harness Connect the black wire on the power cord to the white wire on the rheostat Re attach the green ground terminal to the control plate 12 Insert the control plate assembly back into the appliance as shown Tilt the assembly forward and then lift up and rotate the bottom towards the front of the appliance a...

Page 29: ...S WHERE SUCH ACTION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO ST...

Page 30: ...verage under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty period for this manufacturer s warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy...

Page 31: ...upplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or 9 interruptions or fluctuations of electrical power supply to the appliance Non HHT venting components hearth components or other accessories used in conjunction with the appliance Any part of a pre existing f...

Page 32: ...and Service Parts R GRAND MBK AU Beginning Manufacturing Date April 2013 Ending Manufacturing Date Active Cast Iron Wood Insert Large Part number list on following page Grand MBK AU 8 1 3 4 5 10 11 6 8 12 13 14 16 17 18 19 20 21 23 24 7 22 15 9 2 ...

Page 33: ...rd SRV7075 186 Y 7 BafÀe Protection Channel SRV7046 165 Y 8 Tube Support Rack SRV7075 193 Y Screw Hex Washer Head Ms 1 4 20 x 3 4 Pkg of 25 220 0080 25 Y 9 Tube Channel Assembly SRV7075 004 Y Screw Hex Washer Head Ms 1 4 20 x 3 4 Pkg of 25 220 0080 25 Y Nut Ser Flange samll 1 4 20 Pkg of 24 226 0130 24 Y 10 Brick Assembly SRV7075 021 10 1 Brick 1 9 x 4 50 x 1 25 Pumice Qty 12 req 10 2 Brick 2 4 5 ...

Page 34: ...450 2810 Screw 10 32 x 0 75 Hex Washer Head Ser Flg 7000 618 4 Y 13 Door Assembly SRV7063 009MBK 13 1 Screw Pan Head Phillips 8 32 x 3 8 Pkg of 40 225 0500 40 Y 13 2 Hinge Retainer SRV7063 160 13 3 Door SRV7075 123MBK 13 4 Door Handle Assembly SRV7063 014 Y 13 5 Fiber Handle SRV7060 212 Y 13 6 Door Handle SRV7063 137 13 7 Washer Sae 3 8 3 ea Pkg of 3 832 0990 Y 13 8 Key cam Latch 430 1151 13 9 Cam...

Page 35: ...7063 125MBK Bolt Hwh Ser Flg 1 4 20 x 3 4 Pkg of 25 228 0120 25 Y Washer Bonded 5 16 x 3 4 Pkg of 10 229 0910 10 Y 14 2 Hinge Continous 7000 510 Screw Flat Head Phillips 8 32 x 1 2 Pkg of 12 220 0490 12 Y 14 3 Access Matte Black SRV7075 127MBK Screw Flat Head Phillips 8 32 x 1 2 Pkg of 12 220 0490 12 Y 14 4 Ash Lip Matte Black SRV7075 135MBK Bolt Hwh Ser Flg 1 4 20 x 3 4 Pkg of 25 228 0120 25 Y Wa...

Page 36: ... Pkg of 10 7000 622 10 Y 19 Combustion Cover Assembly SRV7075 196 Screw Sheet Metal 8 x 1 2 S Grip Pkg of 40 12460 40 Y 20 Leg Extension Left or Right SRV7046 170 21 Burn Rate Control Assembly SRV7075 005 Y Screw Hex Washer Head Ms 1 4 20 X 3 4 Pkg of 25 220 0080 25 Y Screw Sheet Metal 8 x 1 2 S Grip Pkg of 40 12460 40 Y 22 Timer Control Assembly SRV7075 007 Y Screw Pan Head Phillips 8 32 x 3 8 Pk...

Page 37: ...when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 25 Surrounds Cast Matte Black SP GRAND CC MBK 25 1 Surround Right Matte Black SRV7075 131MBK 25 2 Surround Top Matte Black SRV7075 129MBK 25 3 Surround Left Matte Black SRV7075 133MBK 25 4 Surround Retainer Qty 4 req SRV7063 136 25 5 1 4 20 x 50 Phillips Pan Head Screw Pkg of 12 322...

Page 38: ...d at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 26 1 Trim Leg Right Matte Black 414 7130MBK 26 2 Trim Header Matte Black 414 7110MBK 26 3 Trim Leg Left Matte Black 414 7120MBK 26 4 Trim Footer Left Matte Black 414 7090MBK 26 5 Trim Footer Right Matte Black 414 7100MBK Component Pack SRV7063 055 Surrounds Metal Standard SP GRAND STD Large SP GRAND LRG Trim Kit Black TRIMKIT 4331 BK Gold TRIMKIT 43...

Page 39: ...October 12 2015 7075 205B Page 39 Voyageur Grand ...

Page 40: ...otes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadra...

Reviews: