F. Appliance Break-In

Initial Break-in Procedure
•  The fireplace should be run three to four hours 

continuously on high.

• Turn the 

fi

 replace off and allow it to completely cool.

• Remove 

fi

 xed glass assembly. See Section 4.B.

• Clean 

fi

 xed glass assembly. See Section 4.B.

• Replace the 

fi

 xed glass assembly and run continuously 

on high an additional 12 hours.

This cures the materials used to manufacture the 

fi

 re-

place.

NOTICE! Open windows for air circulation during 

fi

 re-

place break-in.

•  Some people may be sensitive to smoke and odors.
•  Smoke detectors may activate.

G. Heat Management
Heat Output

This model has a variable burn rate which is controlled 

by the HI/LO switch on the control module.  Therefore the 

fl

 ame height is adjustable. The HI/LO switch is shown in 

Figure 3.6.  It is located in the control cavity of the appli-
ance.  

If a remote control is installed, the 

fl

 ame height may also 

be controlled by the remote, if 

fl

 ame height is a function 

of that particular model of remote control.
If an optional fan is installed, the fan speed is controlled 
by adjusting the speed control knob.  Turn the knob 
clockwise to increase the fan speed and counterclockwise 
to decrease the fan speed.

Summary of Contents for GARN-D-CSB-IPI

Page 1: ...nts for location of additional Commonwealth of Massachusetts requirements DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to do i...

Page 2: ...liance information below Dealer Name ________________________________________________________ Address ____________________________________________________________ _____________________________________...

Page 3: ...mation A Appliance Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specific...

Page 4: ...on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independ...

Page 5: ...HE EXPRESSED WARRANTY SPECIFIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color...

Page 6: ...est edition in the U S A and the CAN CGA B149 Installation Codes in Canada 2 2 Product Specific Information B Glass Specifications Ceramic This appliance is equipped with 5 mm ceramic glass Re place g...

Page 7: ...s of high temperatures High temperatures may ignite clothing or other flammable materials Clothing furniture draperies and other flammable materials must not be placed on or near the appliance Young c...

Page 8: ...place WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed Figure 3 2 General Operating Parts B General Operating Parts C Fuel Specifications Figure 3 2 re...

Page 9: ...on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 V...

Page 10: ...circulation during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate G Heat Management Heat Output This model has a variable burn rate which is controll...

Page 11: ...e control cavity of the appliance See Figure 3 5 for location 2 Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 3 A...

Page 12: ...ch and the RC300 remote control to operate your fireplace the appliance switch will override any commands given by the remote 5 Module Reset This module may lock out under certain conditions When this...

Page 13: ...To be completed by Glass Cleaning Seasonally Homeowner Remote Control Seasonally Venting Seasonally Gasket Seal and Glass Inspection Annually Qualified Service Technician Log Inspection Annually Fire...

Page 14: ...eded in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your fireplace for an extended period of time summer months vacations trips etc to...

Page 15: ...Use caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition an...

Page 16: ...ng of the paint and the burning off of any oils remaining from manufacturing If appliance has not been used for some time dust can build up and cause an odor Film on the glass This is a normal result...

Page 17: ...Check voltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than 4...

Page 18: ...ensing rod to white sensor wire Polish flame sens ing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms...

Page 19: ...ildren See your dealer if you have questions Optional Fan If an optional fan is purchased have it installed by a qualified service technician Section 3 discusses using the fan to manage the heat outpu...

Page 20: ...Parts R GARN MBK GARN D IPI Beginning Manufacturing Date June 2014 Ending Manufacturing Date Active Part number list on following page Log Set Assembly 3 1 2 Gas Stove DV 05 14 GARNET D CSB GARNET MB...

Page 21: ...Coat Black 7016 109MBK Sienna Bronze 7016 109CSB Mahogany 7016 109PMH 6 Grommet 2118 420 7 Pilot Shield 2344 103 8 Pilot Assembly 2090 012 Y 9 Burner Assembly 2344 007 Y 10 Door Assembly GLA 2344 019...

Page 22: ...ly to consumers Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 27 1 Blower Shroud Top 2344...

Page 23: ...g service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 18 1 Battery Pack 2166 323 18 2 Junction Box 4021 013 Y 18 3 Transformer 2326 131 Y 18 4 Componen...

Page 24: ...__________________________________________________________ ________________________________________________________________________________ ____________________________________________________________...

Reviews: