4.  Glass Cleaning
• Frequency: 

As desired

• By:

 Homeowner

Clean  glass  with  a  non-abrasive  glass  cleaner.   Abrasive 

cleaners  may  scratch  and  cause  glass  to  crack.   

If the 

deposits on the glass are not very heavy, normal glass 

cleaners  work  well.  Heavier  deposits  may  be  removed  by 

using  a  damp  cloth  dipped  in  wood  ashes  or  by  using  a 

commercially available oven cleaner.  
After using an oven cleaner, it is advisable to remove any 

residue  with  a  glass  cleaner  or  soap  and  water.    Oven 

cleaner left on during the next firing can permanently stain 

the glass and damage the finish on metal surfaces.
A portion of the combustion air entering the firebox is deflected 

down over the inside of the door glass.  This air flow “washes” 

the glass, helping to keep smoke from adhering to its surface.  
When operated at a low burn rate, less air will be flowing over 

the glass and the smokey, relatively cool condition of a low 

fire will cause the glass to become coated.  

Operating the appliance with the Burn Rate Air Control and 

Start-Up Air Control all the way open for 30-45 minutes should 

remove the built up coating. 

CAUTION

•  Do not use polishes with abrasives.  It will scratch surfaces.

Fire Risk.
Disposal of Ashes

WARNING

•  Ashes should be placed in metal container with tight fitting lid.

•  Do not place metal container on combustible surface.

•  Ashes should be retained in closed container until all cinders 

have thoroughly cooled.

3.  Disposal of Ashes
• Frequency: 

When ash is within 1-3/4 in. (44mm) of firebox 

lip

• By:

 Homeowner

Ashes should be placed in a metal container with a tight 

fitting lid. The closed container of ashes should be placed 

on a non-combustible floor or on the ground, well away 

from all combustible materials, pending final disposal. If 

the ashes are disposed of by burial in soil or otherwise 

locally dispersed, they should be retained in the closed 

container until all cinders have thoroughly cooled.

Summary of Contents for EXPLRMED-PBK

Page 1: ...aterials away WARNING If the information in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam ma...

Page 2: ...A chimney suitable for use with solid fuels or a masonry chimney and the referenced clearances DOUBLE WALL Six inch 6 inches 152mm diameter listed double wall air insulated connector pipe with listed...

Page 3: ...s 7 C Mobile Home Approved USA ONLY 7 D Glass Specifications 7 2 Operating Instructions 8 A Over Firing Your Appliance 8 B Wood Selection Storage 8 C Burning Process 8 D Automatic Combustion Control A...

Page 4: ...y coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty s...

Page 5: ...ot cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is...

Page 6: ...he door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the appliance unattended with t...

Page 7: ...ing all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fi...

Page 8: ...p plastic tar paper sheets of scrap plywood etc as uncovered wood can absorb water from rain or snow delaying the seasoning process C Burning Process In recent years there has been an increasing conce...

Page 9: ...ire situation and or burning your wood up too quickly before you shut down the air controls to the desired burn rate With the Automatic Combustion Control ACC system you do not have to continually mon...

Page 10: ...there are hot coals repeating steps 6 through 8 will maintain a continuous fire throughout the season F Burn Rates and Operating Efficiency For maximum operating efficiency This wood appliance has a...

Page 11: ...rd Figure 11 2 Figure 11 1 CORRECT POSITION WARNING Fire Risk Firebox damage due to improper baffle placement is not covered by warranty Operate the wood burning appliance with the baffle in the corre...

Page 12: ...d by the smoke column from a chimney and 0 opacity means that no smoke column can be seen As you become familiar with your appliance you should periodically check the opacity This will allow you to kn...

Page 13: ...appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work a...

Page 14: ...r and then shut the door If you can pull the dollar out remove one washer from door handle behind latch cam and try again If you can still pull it out replace the door gasket Check the glass frame for...

Page 15: ...t has accumulated it should be removed to reduce the risk of a chimney fire a The appliance and ashes must be completely cooled down before using the Ash Removal System Reach down and locate the ash r...

Page 16: ...lowing over the glass and the smokey relatively cool condition of a low fire will cause the glass to become coated Operating the appliance with the Burn Rate Air Control and Start UpAir Control all th...

Page 17: ...y or soft wood Over drafting Use dry kindling and more paper arrange kingling and wood for better air movement Check for restricted termination cap Check for blockage of outside air kit if installed C...

Page 18: ...tely a few turns at a time until the glass is secure DO NOT OVER TIGHTEN 9 Replace the door on the appliance Quadra Fire appliances are equipped with ceramic super heat resistant glass which can only...

Page 19: ...all hot embers before disposal into a metal container 2 The baffle board has 2 pieces With the ceramic blanket still in place slide one baffle piece over the top of other one and pull out top piece t...

Page 20: ...channel nuts 7 16 and 2 bolts 3 8 inside of chamber Figure 20 2 4 Slide the tube channel assembly all the way to left until it is off the threads Drop the right side down then slide the assembly back...

Page 21: ...June 9 2017 7061 196H 21 Explorer II Date of Service Performed By Description of Service A Service Maintenance Log 6 Reference Materials...

Page 22: ...22 7061 196H June 9 2017 Explorer II Date of Service Performed By Description of Service...

Page 23: ...rt number list on following page 03 17 Color SKU No Mfg Dates Matte Black EXPLRMED MBK 03 14 Porcelain Black EXPLRMED PBK 10 14 Porcelain Dark Blue EXPLRMED PDB 10 14 Porcelain Frost EXPLRMED PFT 10 1...

Page 24: ...ansition Assembly SRV29138 5 Top Matte Black 7061 101MBK Porcelain Black 7061 101PBK Porcelain Dark Blue 7061 101PDB Porcelain Frost 7061 101PFT Porcelain Mahogany 7061 101PMH 6 Side Left Matte Black...

Page 25: ...y 1 req 11 5 Brick 5 w angle 9 X 4 5 X 1 25 Qty 2 req 11 6 Brick 6 6 69 X 3 5 X 1 25 Qty 2 req Brick Uncut Must specilfy size when ordering Pkg of 1 832 0550 Pkg of 6 832 3040 12 Ashlip Matte Black 70...

Page 26: ...1151 14 Front Matte Black 7061 103MBK Porcelain Black 7061 103PBK Porcelain Dark Blue 7061 103PDB Porcelain Frost 7061 103PFT Porcelain Mahogany 7061 103 Gasket 7 16 844 3980 15 Andirons 2 pcs SRV7061...

Page 27: ...061 033 Porcelain Mahogany SRV7061 028 Leveling Assembly 7000 000 Paint Touch Up Matte Black 812 0910 Porcelain Black 1 00 0022 Porcelain Dark Blue 1 00 0020 Porcelain Frost 1 00 0021 Porcelain Mahoga...

Page 28: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...

Reviews: