Discovery I
6
Mobile Home Installation
You must use a Quadra-Fire Outside Air Kit Part
OAK-ACC; which is available from you dealer, for
installation in a mobile home.
1.
An outside air inlet must be provided for combustion.
2.
Appliance must be secured to the mobile home
structure by bolting the legs to the floor.
3.
Appliance must be grounded with #8 solid copper
grounding wire or equivalent and terminated at each
end with N.E.C. approved grounding device.
4.
Appliance must be installed with an approved
UL103
HT
ventilated chimney connector,
UL103 HT
chimney,
and terminal cap with spark arrestor. Never use a
single wall connector (appliance pipe) in a mobile home
installation. Use only double-wall connector pipe,
Dura-Vent DVL, Selkirk Metalbestos DS or Security
DL double-wall connector or any listed double-wall
connector pipe.
5. In Canada, this appliance must be connected to a 6
inch (152mm) factory-built chimney conforming to
CAN/
ULC-629M, STANDARD FOR FACTORY BUILT
CHIMNEYS
.
6. Follow the chimney and chimney connector
manufacturer’s instructions when installing the flue
system for use in a mobile home.
7.
Maintain clearance to combustibles.
8.
Floor protection requirements must be followed
precisely.
9.
Use silicone to create an effective vapor barrier at
the location where the chimney or other component
penetrates to the exterior of the structure.
NOTE:
Offsets from the vertical, not exceeding 45°,
are allowed per
Section 905(a) of the Uniform
Mechanical Code (UMC)
. Offsets greater than 45°
are considered horizontal and are also allowed,
providing the horizontal run does not exceed 75%
of the vertical height of the vent. Construction,
clearance and termination must be in compliance
with the
UMC Table 9C.
This installation must also
comply with
NFPA 211.
NOTE:
Top sections of chimney must be removable to
allow maximum clearance of 13.5 feet (411cm)
from ground level for transportation purposes.
Asphyxiation Risk.
NEVER INSTALL IN A SLEEPING ROOM.
Consumes oxygen in the room.
WARNING
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL AND CEILING/ROOF MUST BE
MAINTAINED
Do NOT cut through:
•
Floor joist, wall, studs or ceiling trusses.
•
Any supporting material that would affect the structural
integrity.
10.
Burn seasoned cord wood only. Other types of
fuels may generate poisonous gases (e.g., carbon
monoxide).
11.
If appliance burns poorly while an exhaust blower is on
in home, (i.e., range hood), increase combustion air.
12.
Installation shall be in accordance with the
Manufacturers Home & Safety Standard (HUD) CFR
3280, Part 24.