background image

Page 2

Quadra-Fire  •  Columbia Bay  •  250-5195 Rev.K

10/08

and Welcome to the Quadra-Fire Family

!

Hearth & Home Technologies welcomes you to our tradition 
of excellence!  In choosing a Quadra-Fire appliance, you 
have our assurance of commitment to quality, durability, and 
performance.

This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation of 
our stoves, inserts and fi replaces.  And yet we are old-fash-
ioned when it comes to craftsmanship.  Each appliance is 

meticulously fabricated and gold and nickel surfaces are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.   From design, to fabrication, to shipping: 
Our guarantee of quality is more than a word, it’s Quadra-
Fire tradition, and we proudly back this tradition with a Lim-
ited Lifetime Warranty.  

We wish you and your family many years of enjoyment in the 
warmth and comfort of your hearth appliance.  Thank you for 
choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: ON BACK OF APPLIANCE

Manufactured 
Date

Serial Number

Model Name

Test Lab & 
Report No.

DO NOT REMOVE THIS LABEL / NE PAS 

ENLEVER L’ÉTIQUETTE 

Made in U.S.A. / Fait Aux États-Unis 

MINIMUM CLEARANCES TO COMBUSTIBLES 

ESPACE MINIMUM AUX COMBUSTIBLES 

Minimum clearances required from combustible construction for all 
appliance surfaces.  
Espaces minimum exigés de la construction combustible aux surfaces 
de l’appareil. 

250-5184 

 

This appliance equipped only for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent 
configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for information on making these changes. 
Cet appareil est équipé pour les altitudes de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ 
aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propriétaire pour les informations 
sur ces changements. 
 
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow the National Fuel Gas Code, ANSI 
Z223.1 or Canadian Installation Codes, CAN/CGA-B149. Install and use only in accordance with manufacturer’s installation and operating instructions. NOTE: Have the gas 
supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, 
installation must be performed by a licensed plumber or gas fitter.) 
Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez ANSI Z223.1/CAN 1-B149. 
Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier. 

REMARQUE: Le conduit gaz doit être installé conformément aux codes 

de construction locaux. L'installation doit être effectuée par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la 

République de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.) 

Keep burner and control compartment clean. See installation and operating instructions accompanying this appliance. This vented gas fireplace heater is not for use with air filters. 
Due to high surface temperatures, keep children, clothing and furniture away. 
Gardez le brûleur et le compartiment de contrôle propres. Vérifiez les instructions d’installation et d’opération qui accompagnent cet appareil. Cet appareil de chauffage au gaz n’est 
pas pour l’usage avec des filtres d’air. Du aux surfaces de températures élevées, gardez les enfants, les vêtements et les meubles à distance éloignée

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE 

Blower Electrical Rating / Évaluation du Ventilateur Électrique: 

115 V., 1.5 Amps, 60 Hz, 150 Watts 

Thermal Efficiency / Efficacité Thermique* 
  

84% NG (blower on / avec ventilateur allumé) 

 

86% LP (blower on / avec ventilateur allumé) 

* With Maximum horizontal length. / Avec longueur horizontale maximum. 

P.4.1-02 Canada Minimum pipe

 

(P.4.1-02 Le canada tuyau minimum) 

 

65.42% NG / 65.96% LP 

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS: 
ANSI Z21.88a-2001 / CSA 2.33a-M01 Fournaises au Gaz avec Ventilation, et les sections 
applicable de UL 307b Appareils de Chauffage Au Gaz pour les Maisons Mobiles et les 
Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas Fired Appliances for use at High Altitudes”. 
Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. Pour une conversion 
au gaz propane les pièces du Manufacturier #842-4041 et ses instructions doivent être 
utilisées. Cet appareil peut être utilisé dans une chambre à coucher ou salle de séjour; au 
Canada, l’installation d’un thermostat à distance est exigée. 

APPROVED FOR CANADA AND USA TO: 
ANSI Z21.88a-2001 / CSA 2.33a-M01 Vented Gas Fireplace Heaters, and applicable 
sections of UL307b Gas Burning Heating Appliances for Manufactured Homes 
and Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances for use 
at High Altitudes.” This appliance is manufactured for operation with Natural 
Gas. For conversion to propane Manufacturer’s Part #842-4041 and instructions 
must be used. This appliance may be installed in a bedroom or bedsitting room; 
in Canada remote thermostat installation is required. 

HEARTH: A non-combustible hearth pad is not required. However, the 
floor beneath the stove must be stable, level, and strong enough to support 
the stove without a tipping hazard. 
CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas 
exigé. Cependant, le plancher en dessous du poêle doit être droit, à 
niveau et assez fort pour supporter le poêle sans le hasard de 
basculer. 

 

 

 

For use with Natural Gas 

For use with Propane 

 

 

Usage Au Gaz Naturel 

Usage Au Gaz Propane 

  

0-2000’ 

0-2000’ 

Top Vent:  Input Rate on “HI” (BTU/Hr) 

30,000 

30,000 

Puissance Évaluée à “HI” (BTU/Hr) 

 

Input Rate on “LO” (BTU/Hr) 

21,000 

24,500 

Puissance Évaluée à “LO” (BTU/Hr) 

 

Maximum Output (BTU/Hr)** 

25,250 

25,800 

Puissance Maximum (BTU/Hr)** 

 

Main Burner Orifice 

.1065 (36 DMS) 

.0635 (52 DMS) 

Orifice du Brûleur Principal 

Minimum Inlet Pressure (Inches W.C.) 

4.5” 

11” 

Pression Minimum de la Valve (pouces W.C.) 

Maximum Inlet Pressure (Inches W.C.) 

7.0” 

14” 

Pression Maximum de la Valve (pouces W.C.) 

Manifold Pressure on “HI” (Inches W.C.) 

3.5”                                            10”                   Pression du Collecteur d’ Échappement à “HI”  

  

 

 

(pouces 

W.C.) 

**Max Venting, Blower On 

 

 

** Ventilation Maximum, Ventilateur Allumé 

 

This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions. 
Cet apprareil doit être correctement raccordé à un système d'évacuation, conformément aux instructions du fabricant. 

This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing or with Manufactured Home Construction and Safety Standard, 
Title 24 CFR, Part 3280, or when such standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard. 
WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer's instructions. 
Installer l'appareil selon la norme CAN/CSA-Z240, Serie MM, Maisons mobiles ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces 
normes ne sont pas pertineutes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.

 

AVERTISSEMENT: Ne pas utiliser l'appareil tant que toutes les sections n'ont pas ete assemblees et installees selon les instructions du fabricant. 

A.  Side of stove top to side wall 

6 in. (152 mm) 

        Du coté du poêle au coté du mur 

A*.  In an Alcove 

6-3/4 in. (171 mm) 

        Dans l’alcôve 

B.  Rear of control box to back wall 

2 in. (51 mm) 

        Le contrôle arrière au mur arrière 

C.  Flue pipe to back wall 

6 in. (152 mm) 

        Du tuyau de cheminée au mur arrière 

D.  Flue pipe to side wall 

14 in. (356 mm) 

        Du tuyau de cheminée au mur du coté 

E.  Rear corner of stove top to side wall 

2 in. (51 mm) 

        Du coin arrière du poêle au mur de coté 

F.  Min. Floor to ceiling height (std. room) 

84 in. (2134 mm) 

        Hauteur minimum du plancher au plafond (pièce standard) 

G.  Top of stove to alcove ceiling 

19 in. (483 mm) 

        Du dessus du poêle au plafond de l’alcôve 

H.  Maximum alcove depth 

36 in. (914 mm) 

        Profondeur maximum de l’alcôve 

I. 

Minimum alcove width 

36 in. (914 mm) 

        Largeur minimum de l’alcôve 

G- 

Alcove height 
Hauteur De 
l’Alcôve 

A* 

A* 

Date of Manufacture / Date du Manufacturier 

2005 2006 2007 

Feb  Mar  Apr  May  Jun  Jul  Aug  Sep  Oct  Nov  Dec 

Jan 

 

SAMPLE 

S

A

M

P

LE

 

MODEL / MODÈLE:  

COLUMBIA BAY 

Report  / Rapport  

061-S-19b-5 

  SERIAL  NO. 

800 West Jefferson Street

 Lake City, MN 55041

www.quadrafire.com

VENTED GAS FIREPLACE HEATER.  
NOT FOR USE WITH SOLID FUEL  

FOURNAISE AU GAZ AVEC VENTILATION 

NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE 

002

Barcode

Summary of Contents for Direct Vent Gas Appliance COLBAY-FS-B

Page 1: ...stalledasanOEM installation in manufactured home USAonly or mobile home and must be installed in accordance with the manufacturer s instructions and the manufactured home con struction and safety stan...

Page 2: ...1 02 Le canada tuyau minimum 65 42 NG 65 96 LP APPROUV POUR LE CANADA ET LES TATS UNIS ANSI Z21 88a 2001 CSA 2 33a M01 Fournaises au Gaz avec Ventilation et les sections applicable de UL 307b Appareil...

Page 3: ...rtical Termination 15 Section 6 Gas Information A Fuel Conversions 22 B Gas Pressures 24 C Gas Connection 24 Section 7 Electrical Information A Recommendation for Wire 26 B Connecting to the Appliance...

Page 4: ...nput BTU Minimum Input BTU Orifice Size DMS Efficiency Up To P 4 Columbia Bay FS NG 30 000 21 000 36 84 65 42 Columbia Bay FS LP 30 000 24 500 52 86 65 96 Manufactured Home or Mobile Home installation...

Page 5: ...ust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF A...

Page 6: ...ro tective surface Remove log set and component pack from firebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starti...

Page 7: ...RNING B Clearances Figure 3 1 Model A A B C D E F G H I Columbia Bay FS Inches 6 6 3 4 2 6 14 2 84 19 36 36 Millimeters 152 171 515 152 356 51 2134 483 914 914 NOTE Flooring beneath appliance may reac...

Page 8: ...DISCHARGE OPENING 2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H Min Ft Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12...

Page 9: ...___________________________________________ _ _ QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMA...

Page 10: ...flue WARNING Diagonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45...

Page 11: ...l dimension from the center line of the flue vent to the center of the 90 elbow is 7 ft 2m the horizontal run to the outer wall flange must not exceed 13 ft 4m EXAMPLE 2 If the vertical dimension from...

Page 12: ...s per installation instructions Connect vent sections per installation instructions Maintain all clearances to combustibles Do NOT allow vent to sag below connection point to appliance Maintain specif...

Page 13: ...c around its outside edges so as to make a seal between it and the wall attach termination cap to the exterior wall with the four wood screws provided The arrow on the vent cap should be pointing up F...

Page 14: ...on cap must be sealed with silicone Termination caps shall not be recessed into a wall or siding Fire Risk Explosion Risk Maintain vent clearance to combustibles as specified WARNING Do not pack air s...

Page 15: ...TIONAL RESTRICTION This installation may not have two horizontal sections connected by 90 elbows Figure 5 12 Step 1 Check the installation instructions for required 1 in 25mm clearances air space to c...

Page 16: ...e and elbow connections are in their fully twist locked position Assemble as instructed NOTE 1 If an offset is necessary in the attic to avoid obstructions it is important to support the vent pipe eve...

Page 17: ...ween the storm collar and the pipe OPTIONAL HIGH WIND TERMINATION CAP SECURE FLASHING WITH NON HARDENING SEALANT AND ROOFING NAILS Figure 5 16 MIN 1 in 25mm CLEARANCE CEILING FIRESTOP NAILS MIN 1 in 2...

Page 18: ...he top edges of the support box to make a seal between it and the roof Clean out any combustible material from inside the support box Step 7 Complete the cathedral ceiling installation by following th...

Page 19: ...8 in 3mm diameter holes through the top adapter and into the chimney top Ensure that you are drilling into the metal on the chimney Twist lock the high wind termination cap onto the top adapter Figure...

Page 20: ...framed a wall thimble is required This allows the retro connector to mount directly on the masonry and provide the correct clearances to combustibles Figure 5 26 Step 3 Secure the flashing to the top...

Page 21: ...that the connector is centered in the opening and the mounting holes line up with the masonry wall Step 8 Secure the top adapter to the flashing Use three sheet metal screws through the side of the t...

Page 22: ...t pilot injector valve regulator conversion label TOOLS REQUIRED Power drill a 90 handle is helpful 2 Phillips bit 5 32 in Allen wrench 5 8 in open end wrench If the shutter is removed with the burner...

Page 23: ...actly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of th...

Page 24: ...sachusetts approved 1 2 inch 13mm T handle manual shut off valve and flexible gas connector are connected to the 1 2 inch 13mm control valve inlet If substituting for these components please consult l...

Page 25: ...and connections Do not use open flame After the gas line installation is complete all connections must be tightened and checked for leaks with a commercially available non corrosive leak check soluti...

Page 26: ...mostat 5 Use the following chart for wire sizing 6 Keep wire lengths as short as possible by removing any excess wire length 7 Low voltage and 110 VAC voltage cannot be shared within the same wall box...

Page 27: ...can cause improper and dangerous operation Verify proper operation after servicing Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperature insulation CAUTION Red...

Page 28: ...sed safely WARNING C Door Crown Installation IMPORTANT PREVENT PERMANENT STAINING 2 Screws 2 Screws Use a soft cloth and a window cleaning solution to clean all fingerprint oils from the gold or nicke...

Page 29: ...e appliance E Positioning the Logs While still breakable the logs do not become fragile until after the appliance is burned and they have cured After curing any handling must be done with care as brea...

Page 30: ...ove the existing door from the appliance Remove the crown from the existing door by removing four screws on the back side of the door assembly Pull crown off door face Install replacement door with gl...

Page 31: ...lower housing to appliance Turn power supply back on Blower motor comes standard with 2 male spade wire connectors If your appliance has a different connec tion use the two female spade wire connector...

Page 32: ...lame Improper adjustment can cause sooting in the firebox and or on the outside of a house with a horizontal termination After adjustment tighten nut to lock in place I Vertical Damper Adjustment Figu...

Page 33: ...that there are no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the flow of combustion and ventilation air is not obstructed front grilles and vent caps B Controls...

Page 34: ...t the power from the appliance 4 Open the door of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five...

Page 35: ...detectors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if ap...

Page 36: ...he thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocoup...

Page 37: ...ing exhaust gases back into the system Check for proper vent connection at flue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to...

Page 38: ...tching or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Do NOT clean glass when hot Turn off appliance after 3 4 hours of operation and ALLOW TO COOL...

Page 39: ...t as neces sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect fo...

Page 40: ...Page 40 10 08 Quadra Fire Columbia Bay 250 5195 Rev K B Service and Maintenance Log Date of Service Performed By Description of Service...

Page 41: ...ctual appliance dimensions Use for reference only For clearances refer to Section 3 Figure 12 1 Appliance Dimensions A B F G H I J K C D E Location Inches Millimeter Location Inches Millimeter A 22 1...

Page 42: ...in 184 mm 7 1 4 in 184 mm 5 1 4 in 133 mm 25 1 4 in 641 mm 37 1 4 in 946 mm 49 1 4 in 1251 mm 13 1 4 in 337 mm 13 1 4 in 337 mm 6 5 8 in 168 mm 6 5 8 in 168 mm 6 5 8 in 168 mm 6 5 8 in 168 mm SLP45 SL...

Page 43: ...iling Firestop SLP WS Wall Firestop SLP HVS Pipe Support Hanger 950 Vinyl Protector Kit SL Pipe DRC RADIUS Decorative Radius Cover HTI DV WT Wall Thimble RF4 8 Roof Flashing TERMINATION KITS SLP TRAP2...

Page 44: ...250 5195 Rev K Service Parts Diagram Part number list on following page Log Set Assembly COLBAY FS B Columbia Bay Free Standing 1 2 3 4 5 6 7 8 9 R D Service Parts List Beginning Manufacturing Date Fe...

Page 45: ...alve Cover 474 0240 Adaptor Inner 4 200 2470 Adaptor 6 5 8 7000 162 Baffle Assembly 842 4051 Baffle Hanger 452 0030 Brick Refractory Ceramic 841 0810 Burner Pan 474 0080 Burner Support Kit 842 5190 El...

Page 46: ...30 0730 Y 3 Piezo Ignitor 291 513 Y 4 Knob On Off 571 534 Y 5 Knob Hi Lo 571 533 Y 6 Valve NG 842 0240 Y Valve LP 842 0230 Y Valve Bracket 474 0230 7 Latch Assembly 452 5070 Y 8 Blower 812 4900 Y Blow...

Page 47: ...able under this warranty is limited to the purchase price of the product In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product Adjustments regula...

Page 48: ...zed and approved by HHT in writing This warranty does not apply to non HHT venting components hearth components or other accessories used in conjunction with the installation of this product This warr...

Page 49: ...___________ Columbia Bay Direct Vent Gas Appliance Do NOT discard this manual CAUTION Important operating and maintenance instructions included Read understand and follow these instruc tions for safe...

Reviews: