Page 4
7014-179K
May 6, 2015
R
CB 1200 Pellet Stove
1
Listing and Code Approvals
A. Appliance Certifi cation
D. Glass Specifi cations
B. BTU & Effi ciency Specifi cations
This appliance is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
C. Mobile Home Approved
NOTE:
This installation must conform with local codes. In
the absence of local codes you must comply with the
ASTM
E1509-95, ULC S627-M93, ULC/ORD-C-1482-M1990,
(UM) 84-HUD.
E. Electrical Rating
115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps
NOTE:
Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifi cations and/or price without notice.
Model
CB1200 Pellet Stove
Laboratory
OMNI Test Laboratories, Inc.
Report No.
061-S-21-4
Type
Solid Fuel Room Heater/Pellet Fuel
BurningType
Standard
ASTM E1509-95, ULC S627-M93 and
ULC/ORD-C1482-M1990 Room Heater
Pellet Fuel Burning type and (UM) 84-
HUD, Mobile Home Approved.
State Listing
Colorado, Listed 09-13-05
NOTE: Some generator or battery back-up systems may
not be compatible with the micro-processor electron-
ics on this appliance. Please consult the power supply
manufacturer for compatible systems.
WARNING! Risk of Fire! Hearth & Home Technologies dis-
claims any responsibility for, and the warranty and agency
listing will be voided by the above actions.
DO NOT:
• Install or operate damaged appliance
•
Modify
appliance
• Install other than as instructed by Hearth & Home
Technologies
• Operate the appliance without fully assembling all
components
•
Overfi re
• Install any component not approved by Hearth &
Home Technologies
• Install parts or components not Listed or approved.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualifi ed
installer, service agency or your dealer.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
Note: The appliance is also approved for installation
into a shop.
The Quadra-Fire Classic Bay 1200 Pellet Heater meets the
U.S. Environmental Protection Agency’s emission limits for
pellet heaters sold after May 15, 2015.
This pellet heater needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this pellet heater in a manner inconsistent with operating
instructions in this manual.
EPA Certifi cation #: 955-14
EPA Certifi ed Emissions: 1.1 grams per hour
*LHV Tested Effi ciency: N/A
**HHV Tested Effi ciency: N/A
***EPA BTU Output: 13,500 to 37,600 / hr.
****BTU Input: 18,500 to 51,600 / hr.
Vent Size: 3 or 4 inches, “L” or “PL”
Hopper Capacity: 80 lbs.
Fuel Wood Pellets
* Weighted average LHV effi ciency using data collected during
EPA emissions test.
**
Weighted average HHV effi ciency using data collected during
EPA emissions test.
***
A range of BTU outputs based on EPA Default Effi ciency and
the burn rates from the low and high EPA tests.
****
Based on the maximum feed rate per hour multiplied by
approximately 8600 BTU’s which is the average BTU’s from a
pound of pellets.
This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is used.
The structural integrity of the mobile home fl oor, ceiling, and
walls must be maintained.
The appliance must be properly grounded to the frame of
the mobile home and use only Listed pellet vent Class “L” or
“PL” connector pipe.
A Quadra-Fire Outside Air Kit must be installed in a mobile
home installation. You must order the Outside Air Kit sepa-
rately.
Summary of Contents for CB1200M-MBK
Page 47: ...R May 6 2015 7014 179K Page 47 CB 1200 Pellet Stove E Warranty Policy...
Page 48: ...Page 48 7014 179K May 6 2015 R CB 1200 Pellet Stove...
Page 49: ...R May 6 2015 7014 179K Page 49 CB 1200 Pellet Stove...
Page 50: ...Page 50 7014 179K May 6 2015 R CB 1200 Pellet Stove...
Page 51: ...R May 6 2015 7014 179K Page 51 CB 1200 Pellet Stove...