Page 24
7014-082D
September 1, 2008
R
CB 1200 Pellet Stove
G. Ignition Cycles
1. During each ignition cycle, it is normal to see some
smoke in the firebox. The smoke will stop once the
fire starts.
2. The convection blower will automatically turn on after
your appliance has reached the set temperature on
the “high” setting. This blower transfers heat from your
appliance into the room, and will continue to run after
the thermostat has stopped calling for heat until the
appliance has cooled down.
3. Occasionally the appliance may run out of fuel and shut
itself down. When this happens, the red call light will
be on. To restart it, fill the hopper and press the reset
button.
(See Figure 22.1, page 22)
. When you press
the reset button the red call light will go out. Release
the button and the light will come back on. You should
see a fire shortly. If not, follow the instructions on
page
23
, of “Starting Your First Fire”.
H. Frequently Asked Questions
Odors and vapors released during initial operation.
• Curing of high temperature paint.
• Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION
WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot floor open.
• Cleaning slide plates open.
Do NOT store fuel:
• Closer than required clearances to com-
bustibles to appliance
• Within space required for loading or ash
removal.
ISSUES
SOLUTIONS
1. Metallic noise.
1. Noise is caused by metal expanding and contracting as
it heats up and cools down, similar to the sound pro-
duced by a furnace or heating duct. This noise does not
affect the operation or longevity of your insert.
2. Ash buildup on glass.
2. This is normal. Clean the glass.
3. Glass has turned dirty.
3. Excessive build up of ash. The lower burn settings will
produce more ash, the higher burn settings produce
less. The more it burns on low the more frequent clean-
ing of the glass is required.
4. Fire has tall flames with black tails and is lazy.
4. The feed rate needs to be reduced or the firepot needs
cleaning. Heat exchanger of exhaust blower needs
cleaning.
5. Smokey start-up or puffs of smoke from the airwash. 5. Either the firepot is dirty or there is too much fuel at
start-up and not enough air. Close down feed rate 1/4
inch at a time until this no longer happens.
6. Large flame at start-up.
6. This is normal. Flame will settle down once the fire is
established.
Back side of Firepot
Firepot floor left open
Figure 24.1 - DO NOT LEAVE FIREPOT FLOOR OPEN