                        7022-515G 

 

 

 

     November 27, 2017

CASTILE INSERT

CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.

PART NAME:

DRAWN BY:

SCALE:

MATERIAL:

SHEET:

PART NUMBER:

REV:

THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING 

DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.

ECO #

DATE

BY

REV

UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE:  (2) PLACE DEC : ± 0.03     (3) PLACE DEC: ± 0.005     ANGLE: ± 2°     FRACTION: ± 1/16

OUTSIDE MATERIAL.

NORMAL DIM & INSIDE MATERIAL.

OUTSIDE APEX

INSIDE APEX  -  DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS

REVISIONS

ITEM

PART NUMBER

PART NAME

QTY

NOTE:

1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK

2. BACKGROUND: SILVER

3. COPY: BLACK

4. ADHESIVE: N/A

5. TEMPERATURE RATING: -50°F TO 350°F

D EPA CERTIFIED WAS EXEMPT, CORRECTED ADDRESS

74964

06/10/14

MCW

SERIAL LABEL CASTILE INSERT

MCW

NTS

SEE NOTE

1 OF 1

7022-121

RELEASED

E UPDATED FOR NSPS STANDARDS

77522

05/04/15

TMM

6 UPDATE INFORMATION TO REFLECT HALIFAX MOVE

84515

02/27/17

TPS

6.50

9.75

A

B

C

F

E

Insert

Maximum Mantel Depth - 10 inches 

Fascia or Trim 

D

Masonry or Zero Clearance  

A

B

 

C

 

D

 

E

      

F

 

Dégagement de la maçonnerie ou Dégagement zéro

16 in.   406mm

12 in.   305mm

4.75 in. 121mm

10 in.    254mm

6 in.    152mm

6 in.    152mm

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

AS A BUILT-IN UNIT

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES: 

G

 

 2 in. (51mm

)*

       

 2.5 in. (64mm)**

H

 

 2 in. (51mm)

I

 

 4 in. (102mm)

 

 3 in. (76mm)

COMME APPAREIL INSÉRÉ

0 in. Clearance To Exposed Section and Face Trim / Espace libre 

de 0 mm de la section exposée et de la garniture du devant.

*Top Vent 

Des Conduits Du Haut

**Rear Vent 

/

 Des Conduits Arrières

   Side Wall  / Mur De Côté 
   Back Wall to Insert / Mur Arrière du 

Insére

   Back Wall to Flue Pipe / Mur Arrière Tuyau Rigide  

NE PAS ENLEVER L'ÉTIQUETTE

DO NOT REMOVE THIS LABEL

Listed Solid Fuel Room Heater/Pellet Type Insert. “For Use with Solid Wood Fuel and Shelled 

Field Corn Only”. Also suitable for Mobile Home Installation.  This appliance has been tested and 

listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.

PREVENT HOUSE FIRES

Install and use only in accordance with manufacturer's installation and operating instructions.  

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND 

INSTALLATION INSPECTIONS IN YOUR AREA.

WARNING: FOR MOBILE HOMES:

  Do not install appliance in a sleeping room.  An outside 

combustion air inlet must be provided.  The structural integrity of the mobile home floor, ceiling 

and walls must be maintained.

Refer to manufacturer's instructions and local codes for precautions required for passing chimney 

through a combustible wall or ceiling.  Inspect and clean vent system frequently in accordance 

with manufacturer's instructions.

DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.

Use a 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system.

Tested to: ASTM E1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room Heating Pellet 

Burning Type,  (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD. DO NOT USE ANY OTHER 

TYPE OF FUEL. OMNI-Test Laboratories, Inc. has determined that this appliance complies with 

Canadian Standards Association (CSA) B415.1 and Title 40 of the U.S. Code of Federal 

Regulations, Part 60, SubPart AAA.OMNI-Test Laboratories Accrediations:  The Standards 

Council of Canada, the American National Standards Institute, and the U.S. Environmental 

Protection Agency.

Input Rating:  38,700 BTU/HR.

Electrical Rating:  115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps.

Route power cord away from unit. Do not route cord under or in front of appliance.

DANGER:

  Risk of electrical shock.  Disconnect power supply before servicing. 

Replace glass only with 5mm ceramic available from your dealer.  

To start, set thermostat above room temperature, the stove will light automatically.  To shutdown, 

set thermostat to below room temperature.  For further instruction refer to owner's manual.

KEEP VIEWING AND ASH REMOVAL DOORS TIGHTLY CLOSED DURING OPERATION.

PRÉVENTION DES FEUX DE MAISON

Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. CONTACT 

BÂTIMENT LOCAL OU POUR CONNAÎTRE LES RESTRICTIONS ET INSPECTIONS INSTALLATION DANS 

VOTRE RÉGION.

AVIS - Pour Les Maisons Mobiles:

  Ne pas installer dans une chambre à coucher. Un tuyau extérieur de 

combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure 

intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.

Référez vous aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une 

cheminée à travers un mur ou un plafond combustibles, et les compensations maximums.

Inspectez et nettoyez la cheminée fréquemment. 

Ne pas connecter cet appareil à une cheminée servant un autre appareil.

Utilitsez le système de ventilation de 3 or 4 inch (76-102mm) de diametre de type “L” ou “PL”.

Testé à: ASTM #1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room Heating.  Pellet Burning Type, (UM) 

84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS.   

OMNI-Test Laboratories, Inc. a déterminé que cet 

appareil se conforme avec la norme de l’Association Canadienne de normalisation (CSA) B415.1 ainsi que le Titre 40 du 

Code Fédéral de Régulations des États-Unis, partie 60, sous-partie AAA.   Accréditations OMNI-Test Laboratories : Le 

Conseil Canadien des Normes (CCN/SCC), l’Institue des Standards Nationaux Américain (ANSI) et l’Agence de Protection 

Environnemental (EPA).

Puissance de Rendement:  38,700 BTU/HR

Puissance Électrique: 115 VAC, 60 Hz, Début 4.1 Amps, Courir 1.1 Amps, 

Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.

DANGER

: Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise de contact avant le service.  

Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.

Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera 

automatiquement.  Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce.  

Pour des instructions supplémentaires, référez vous au manuel du propriétaire.  Gardez la porte d'ouverture et la porte 

des cendres fermées hermétiquement durant l'opération.

Appareil de chauffage inséré de combustible solide/de type de boulettes.  “Pour Usage Avec Bois Solide et 

Champ de Maïs égrené Seulement”.  Accepté dans l'installation dans les maisons mobiles.  Cet appareil a 

été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 

814-23-909.

7022-121_R6

Garniture 

de façade

Mantel/Manteau

Sidewall / Mur Latéral

Insére

Profondeur Maximale Mantel - 254mm

*When constructing floor protection for your pellet appliance, any parts or 

materials used, must be non-combustible.

* Lors de la construction de protection de sol pour votre appareil à 

granules, toute pièces ou matériaux utilisés, doivent être incombustibles.

H

J

I

G

H

K

I

2017

 

2018 2019 

JAN FEB MAR

APR MAY JUN

JUL AUG SEP

OCT NOV DEC

®

Castile Pellet Insert-B

Made in U.S.A. of US and 

imported parts.

États-Unis-d’Amérique par des 

pièces d’origine américaine et 

pièces importées.

Report / Rapport
#061-S-77d-6.2

SAFETY LABEL / ÉTIQUETTE DE SÉCURITÉ

Fabriqué par

:

Manufactured by:

352 Mountain House Road, Halifax, PA 17032

www.quadrafire.com

U.S. ENVIRONMENTAL PROTECTION AGENCY        OMNI Test Laboratories, Inc., Portland, OR Report/Rapport 061-S-77d-6.2

U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH 2015 PARTICULATE EMISSIONS STANDARDS AT 1.8 G/HR EPA METHOD 28 AND 5G. NOT APPROVED FOR SALE AFTER MAY 15, 2020

THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE 

THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL

Serial No. / N° de série

HF

BARCODE LABEL

A. Sample of Serial Number / Safety Label

LOCATION:  Riveted to appliance behind left side panel.  Remove cast side and swing label forward

Mfg Date

Mfg By

Serial Number

Model

Test Lab & 

Report No.

NOTE:  Clearances may only be reduced by means 

approved by the regulatory authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Summary of Contents for CASTILEI-MBK

Page 1: ...jury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over f...

Page 2: ...e R f rez vous aux instructions du fabricant et des codes locaux pour les pr cautions requises pour passer une chemin e travers un mur ou un plafond combustibles et les compensations maximums Inspecte...

Page 3: ...ting Instructions 7 A Fire Safety 7 B Non Combustible Materials 7 C Combustible Materials 7 D Fuel Material and Fuel Storage 7 E General Operating Information 8 F Before Your First Fire 8 G Clear Spac...

Page 4: ...e construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs...

Page 5: ...es not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and...

Page 6: ...y cause a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions B BTU Efficiency Specifications C Glass Speci...

Page 7: ...ts Shelled field corn other biomass fuels Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains ba...

Page 8: ...ids clear of appliance Do NOT store flammable materials in the appliance s vicinity NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN...

Page 9: ...e back on You should see a fire shortly If not follow the instructions on page 8 Starting Your First Fire L Insert Removal In the case that service or inspection is required the appliance may need to...

Page 10: ...n settings will produce more ash the higher burn settings produce less The more it burns on low the more frequent clean ing of the glass is required 4 Fire has tall flames with black tails and is lazy...

Page 11: ...ellets Every 5 bags of fuel OR X Ash Pan Burning Alternate Fuels Every 1 bag of fuel OR X Ash Removal from Firebox More frequently depending on the fuel type or ash build up OR X Auto Clean Inspection...

Page 12: ...r clinkers may have to be removed from the top of the fire pot Corn clinkers can be especially difficult to break up c The fire pot floor plate must be fully closed when finished WARNING Disposal of A...

Page 13: ...ce cleaning 8 Cleaning the Glass Frequency When clear view of the fire pot is obscure By Homeowner a Appliance must be completely cool before cleaning glass b Use a damp paper towel or any non abrasiv...

Page 14: ...the appliance is allowed to cool has been unplugged and the exhaust blower is off b Remove all ash from the firebox and vacuum thoroughly c Paint all exposed steel including cast iron Use the Touch U...

Page 15: ...s about two months before the batteries are depleted Even if the warning does not appear you should replace batteries once a year see Figure 15 1 If batteries are inserted within two minutes the time...

Page 16: ...Call light on No fire Partially burned fuel in fire pot Fire pot clean out plate not closed Fire pot is dirty missed ignition Check that fire pot clean out plate is fully closed Clean fire pot Make su...

Page 17: ...ss of vacuum Empty hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 screws and jiggle feed assembly Check...

Page 18: ...panels Change fuel brand to pre mium Check that fire pot clean out plate is fully closed Reduce feed rate using feed rate adjustment control rod located inside hopper Nuisance shutdowns Low flame Sawd...

Page 19: ...re purple white and the wires from the blower are black f The blower is held in place with a wing screw g Re install in reverse order A Blower Replacement 1 Combustion Exhaust Blower Replacement a If...

Page 20: ...gure 21 4 6 The baffle does not completely cover the top of the firebox There is an opening on the left as shown in Figure 21 5 Tabs Figure 20 4 Figure 20 5 B Baffle Brick Replacement 1 Follow proper...

Page 21: ...November 27 2017 7022 515G 21 CASTILE INSERT Figure 21 2 Figure 21 3 Figure 21 4 Lift brick pull forward at an angle and drop down into notches Figure 21 1 Re installing Baffle Brick Set Cont d...

Page 22: ...igniter wires are clear of any movement i e ash drawer fire pot cleaning rod cleaning slide plates etc 5 Re install the ash drawer and then re install the side panel and re connect the power E Glass R...

Page 23: ...ry 10 seconds for 60 seconds depending upon setting and then will stop E NOTE Do NOT open the control box This will void the warranty If you need to plug in or remove the control box you must first un...

Page 24: ...it remove the right side panel If the fire tries to burn back into the feed system or push exhaust up the feed tube this snap disc will shut the entire system off This disc must be manually reset Pow...

Page 25: ...RIGHT SIDE Control Box Junction Box Reset Button Heat Output Switch Power Cord Outlet Thermostat Block Fuse Red Call Light R ed G reen Am ber Light Blue Light Firepot Cleaning Rod Cleaning Rods 10 He...

Page 26: ...26 7022 515G November 27 2017 CASTILE INSERT C Service and Maintenance Log Date of Service Performed By Description of Service...

Page 27: ...November 27 2017 7022 515G 27 CASTILE INSERT Date of Service Performed By Description of Service...

Page 28: ...28 7022 515G November 27 2017 CASTILE INSERT Date of Service Performed By Description of Service...

Page 29: ...g Manufacturing Date Active Castile Insert B Castile Pellet Insert CASTILEI MBK CASTILEI PMH CASTILEI CSB CASTILEI CWL Feb 2011 Thru June 2011 Part number list on following pages 1 2 3 4 8 9 7 6 5 10...

Page 30: ...Y 6 Side Matte Black 414 0050BK Mahogany SRV414 0050PMH Sienna Bronze SRV414 0050CSB 7 Glass Assembly Side 1 Piece 5 7 8 in W x 9 in H Interchangeable SRV414 5380 Y Gasket Channel 1 8 x 1 1 4 10 Ft 7...

Page 31: ...Hinge Female SRV450 2910 23 5 Glass Assembly w gasket 17 1 4 W x 11 5 8 H SRV7001 038 Y Gasket Tadpole 10 Ft 842 5130 Y Tape 1 2 x 1 16 10 Ft 240 0290 10 Y Tape Door Corner SRV7027 227 Y 23 6 Retaine...

Page 32: ...pter Assembly SRV414 5850 33 Blower Retainer SRV7058 148 34 Snap Disc 2 SRV7000 268 Y 35 Snap Disc Manual Reset 3 SRV230 1290 Y 36 Convection Blower 150 CFM 812 4900 Y 37 Feed Adjustment Plate SRV7022...

Page 33: ...CWL Power Cord 812 1180 Y Harness Thermostat Wire SRV230 0810 Fuse 7 Amp Junction Box Pkg of 10 812 0380 10 Y Hose Vacuum 5 32 Id 3 Ft SRV240 0450 Y Hopper Lid Magnetic Switch SRV7000 375 Y Reset But...

Page 34: ...hermostat Programmable WALL STAT P Trim Cast Matte Black 811 0930 Footer Left 414 7090MBK Footer Right 414 7100MBK Header 414 7110MBK Trim Leg Left 414 7120MBK Trim Leg Right 414 7130MBK Trim Cast Mah...

Page 35: ...veling Bolt Pkg of 25 220 0080 25 Y Nut Capped Push 1 4 Pkg of 24 7000 157 24 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y Nut Wing 8 32 Pkg of 24 226 0160 24 Y Screw Flat Head 1 4 20 Pkg of...

Page 36: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...