16
02/23
7021-802K
SOFTWARE RESET:
Software reset is used to erase ALL temperature events, and
to return all user-adjustable software settings back to their
original factory default settings.
To Perform a Software Rest:
1. Verify the thermostat’s keypad is not locked.
2. Move TEMPERATURE switch to OFF.
3. Press and hold the UP, DOWN, and NEXT buttons all
at the same time for at least 5 seconds. When the LCD
display screen will become fully populated let go of all
buttons at that point the screen will return to normal.
The clock will have to be changed to match the current day
and time.
S. Thermostat Battery Replacement
This thermostat is powered by two “AA” Alkaline batteries.
The batteries should be replaced AT LEAST once per year to
ensure reliable operation or sooner if the LO BATT appears
on the display screen. The batteries are located on the back
of the thermostat’s circuit board. The front portion of the
thermostat can be removed from the back half by using the
tabs on the top edge of the thermostat housing
(Figure 16.1)
.
Figure 16.2
- Full battery icon
Figure 16.3
- Low battery icon
Figure 16.1
CONNECT THERMOSTAT WIRES TO APPLIANCE:
There is a 4 screw terminal block located on the back
lower left corner of the stove directly above the power cord
inlet. The center 2 screws are for the thermostat wires
(Figure 16.4)
.
When installing new batteries, it is recommended using only
brand new “AA” size alkaline batteries. Please verify the
polarity markings shown in the battery compartment before
adding batteries to the compartment. When finished, line
up the front of the thermostat to the base, and firmly press
together to securely latch the front and back halves together
properly.
BATTERY GRAPHIC:
Anytime time the batteries are physically present in the
thermostat, there will be a visual indicator showing the life of
the battery. This will appear on the display screen
(Figures
16.2 and Figure 16.3)
.
Figure 16.4
TERMINAL BLOCK
CENTER 2 SCREWS FOR
THERMOSTAT WIRES
POWER OUTLET
FUSE
Fuse
Shock hazard.
•
Do NOT remove grounding prong
from plug.
• Plug directly into properly grounded 3
prong receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front
of appliance.
CAUTION