Page 20
250-7251F
September 1, 2008
R
Castile Pellet Insert
1. Open the hinged cast face and open the glass door
assembly.
2. Positioning the logs.
Place the right rear log as shown. There is a notch in
the bottom of the log for clearance for the thermocou-
ple and thermocouple cover (ceramic protection tube).
Figure 20.1
Continue placing the last 3 logs around the firepot as
show in
Figures 20.2, 20.3
and
20.4
.
Be careful not to
block the drop tube in the back of the firebox where pel-
lets feed into the firepot.
Four Piece Log Set Installation
Place the log over the firepot. The charred
area on the log is turned toward the back, not
the front.
The log will be about 2-1/2 inches (64mm)
above the firepot when in place. It must rest
on the 3 logs in a stable position to prevent it
from falling into the firepot.
Figure 20.5.
G. Optional Log Set Placement Instructions
Notch
Thermocouple
Cover
Drop Tube
Figure 20.1
CAUTION
Logs are FRAGILE. Use extreme care when handling or
cleaning logs.
NOTE:
Due to the abrasive nature of a pellet appliance fire, the
logs are not covered under warranty. Any placement varia-
tion other than shown here can cause excessive heat and
shall void the appliance warranty.
Figure 20.2
Figure 20.3
Figure 20.4
Top Log Installation