Fire burns too fast or room 

temperature is overshooting 

the set point of the 

thermostat

Extremely dry or soft wood

Mix in hardwood.
Mix in less seasoned wood after fire is established 

(refer to Wood Fuel Section).

Overdrafting

Check for correct vent height; too much vertical 

height creates overdrafting.
Check location of vent termination (refer to 

Chimney Termination Requirement Section).

Thermostat is not operational or 

is programed incorrectly.

Refer to specific instructions for thermostat used 

for proper programming method.  Refer to field 

diagnostics to ensure that signal from thermostat 

is being interpretted by circuit board correctly.

Too much fuel was loaded into 

appliance when reloaded.

Proper amounts of fuel must be loaded based on 

specific home conditions and exterior weather 

conditions.  

Air control is not closing to 

reduce burn rate.

This could be related to any of the conditions 

found above.  Refer to the field diagnostics to 

perform some testing.

Thermocouples in appliance are 

no longer in proper position.

The theromocouples that sense the condition of 

the fire in the appliance must be in the proper 

location.  A hit from loading fuel or other event 

may have caused them to bend excessivly.  In a 

cool appliance they can be bent back into proper 

postion.

Thermocouple failure.

This will be indicated by a blinking light on the 

activation button.  Refer to diagnostics.

Fan not operating properly

Fan not turning on when 

appliance is hot.

Check that the rotational position of the power 

level knob is on a selected power level rather than 

off.

AC power is not available.  The fan will not 

operate when the appliance operating in battery 

backup mode.  

Check that the fan is plugged into the back of the 

appliance.

Fan is running at maxium setting 

all the time.

This could indicate a failure of the thermocouples 

in the appliance.  This condition will also be 

indicated by a blinking light on the activation 

button.  Refer to diagnostics. 

 

Troubleshooting Guide con’t

22

Quadra-Fire • Adventure-III Owner’s Manual • 4083-900 • Rev D • 09/15

Summary of Contents for Adventure-III

Page 1: ...injury or death WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glas...

Page 2: ...enance Log 26 B Service Parts Accessories 27 C Contact Information 32 1 Welcome A Congratulations 3 B LIMITED LIFETIME WARRANTY 4 2 Product Specific Information A Appliance Certification 6 B BTU Effic...

Page 3: ...ps 60 Hz Route power cord away from unit Do not route cord under or in front of appliance DANGER Risk of electrical shock Disconnect power supply before servicing Replace glass only with 5mm ceramic a...

Page 4: ...on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no l...

Page 5: ...a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated o...

Page 6: ...connector glows you are overfiring Any such action that may cause a fire hazard A Appliance Certification NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its p...

Page 7: ...e materials gasoline and other flammable vapors and liquids clear of the appliance Do NOT store flammable materials close to the appliance use gasoline lantern fuel kerosene charcoal lighter fluid or...

Page 8: ...cause a structure fire Ceramic Blanket and Baffle Board are NOT in contact with the back of the firebox Ceramic Blanket is NOT in contact with the back of the firebox and NOT even with the Baffle Boa...

Page 9: ...insulating proper ties Do not operate the appliance without bricks and refractory board in place Make sure bricks are installed as shown in Figure 3 3 Do not use a grate simply build a fire on the fi...

Page 10: ...othing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down Figure 3 4 General Operating Parts 5 Fan Speed Control option...

Page 11: ...calling for heat then the light stays green for as long as the appliance is burning on high No Light The appliance will progress into a shutdown phase and slowly cool down and the light will turn off...

Page 12: ...nwanted time periods except Wake Saturday and Sunday can be programmed individu ally by changing the format from 5 2 to 5 1 1 To change the format 1 Press and hold the up button and the center button...

Page 13: ...Materials containing asbestos 7 Construction or demolition debris 8 Railroad ties or pressure treated wood 9 Manure or animal remains However if at all possible the best arrangement is to have a mix o...

Page 14: ...s high a moisture content now as it did when it was cut To season wood Cut logs to size Split to 6 in 152 mm or less Air dry to a moisture content of around 20 Soft wood about nine months Hard wood ab...

Page 15: ...t least annually be fore lighting or once every two months during heating season When creosote has accumulated it should be removed to reduce the risk of a chimney fire D Building a Fire 1 First Fire...

Page 16: ...second Left thermocouple error call your dealer 3 fast red blinks then no color for 1 second Right thermocouple error call your dealer 1 red blink every 1 2 second continually Overfire indication do n...

Page 17: ...tton on the thermostat to start the programmed event 3 Lighting the Fire 1 Set the thermostat to the desired temperature 2 Push the SBT button the air control will open and the light should illuminate...

Page 18: ...illness or possible death Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance WARNING Do NOT store flammable materials in the appliance s vicinity...

Page 19: ...ill pull it out replace the door gasket Check the glass frame for loose screws to prevent air leakage Check glass for cracks WEEKLY or After Every 25 Loads of Wood Check the door latch for proper adju...

Page 20: ...mney once every two months during heating season Remove creosote to reduce risk of chimney fire Ignited creosote is extremely HOT Fire Risk Disposal of Ashes WARNING Ashes should be placed in metal co...

Page 21: ...re Competition with exhaust devices Do not use exhaust fans during start up Open window below the appliance towards the wind Activation button not pressed when starting fire Press activation button an...

Page 22: ...the field diagnostics to perform some testing Thermocouples in appliance are no longer in proper position The theromocouples that sense the condition of the fire in the appliance must be in the prope...

Page 23: ...hutdown too quickly or too much heat when commanded to shutdown Three fast blinks of red light then long off 1 sec Right Thermocouple burned out open circuit Appliance will exhibit either late or prem...

Page 24: ...glass Avoid striking scratching or slamming glass Do NOT clean glass when hot Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Refer to maintenance instructions CAUTIO...

Page 25: ...ed the guards will come down 8 Next you will need to remove 2 screws from the side panel of the appliance for the thermocouple that you are replacing The screws are found on the back side of the appli...

Page 26: ...Date of Service Performed By Description of Service A Service Maintenance Log 7 Reference Materials 26 Quadra Fire Adventure III Owner s Manual 4083 900 Rev D 09 15...

Page 27: ...Baf e Blanket SRV4083 205 4 Baf e Qty 2 req SRV4083 113 5 Thermocouple Qty 2 req SRV4083 147 6 Sensor Shield 2 pcs SRV4083 212 Door Assembly See Following Pages Manifold Tube Set TUBES 4083 Y 7 Manifo...

Page 28: ...12 Pedestal Assembly SRV4083 017 12 1 Control Plate Assembly SRV4083 035 12 2 Battery Backup SRV4083 177 Y 12 3 Pedestal Catch Bracket SRV4083 197 12 4 Pedestal Door Assembly SRV4083 033 12 5 Door Han...

Page 29: ...SRV4083 202 16 3 Brick 9 15 16 x 4 1 2 x 1 1 4 Qty 6 req SRV4083 208 16 4 Brick 13 1 4 x 4 1 2 x 1 1 4 Qty 14 req SRV7000 306 17 Refractory Assembly SRV4083 026 17 1 Refractory Bottom Qty 3 req SRV40...

Page 30: ...Pins 1 2 Qty 2 Gold 832 0250 Qty 2 Nickel 430 5320 19 2 Rope Door 3 4 x 84 Field cut to Size 7 Ft Length 832 1680 Y 19 3 Door Glass Assembly 17 5 8 W x 11 1 2 H 7000 014 Y Gasket Glass Tape Field cut...

Page 31: ...Wire Harness AC SRV4083 176 Y Wire Harness Blower AC SRV4083 178 Y Manifold Clip Screw 832 0661 Component Pack SRV4083 030 Power Cord 812 1180 Y Wire Harness TSTAT Block SRV7080 152 Y Thermostat Progr...

Page 32: ...oduct may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending DO NOT DISCARD THIS MANUAL CAUTION Important...

Reviews: