14-2 w/ground
Standard wall mount with
Junction Box
14-3 w/ground
WIRE NUT
WHITE
GREEN
BLACK
BLACK
RED
WHITE
Match colors to wire
harness (red to red,
white to white, etc) and
secure with a wire nut
Incoming Power
(110V)
Power to the Fireplace
Snap Disc
bypass switch
Figure 4.1 Fan Wiring Diagram
NOTICE:
The manual override switch, rheostat speed
control and cover plate are supplied. You will need to supply:
14-3 wire with ground; 14-2 wire with ground; standard wall
mount junction box; wire nuts.
• Remove junction box cover plate on the bottom right
side of the fireplace.
• Thread the 14-3 with ground wire through the opening
with the strain relief on the cover plate.
• Match colors to wire harness, (red to red, white to white,
etc.) and secure with wire nuts.
WARNING! Risk of Fire! DO NOT
apply combustible fin-
ishing materials over any part of the front of this fireplace.
• The metal fireplace face may only be covered with
noncombustible materials such as ceramic tile, brick,
or stone.
• Do not cover or block any cooling air slots.
NOTICE:
Wiring for fans must be done before framed
enclosure is completed. If using a Heat Zone kit, it also must
be installed before enclosure is complete.
4
Electrical Wiring
23