B. Disassemble Firebox and Outer Can
For easier fi eld installation the outer can is installed with-
out the fi rebox so connecting to the fl ue has greater access.
The fi rebox slides into the outer can once the fl ue collar is
attached to the stove pipe/liner and optional outside air fl ex
pipe is installed.
1. Remove the fl ue collar by cutting the wire ties. Set the
fl ue collar and attachment bar aside.
2. Remove the 2 screws holding the timer assembly in place
and remove the timer.
Figure 38.1
.
3. Remove the 2 Phillips head bolts underneath the ashlip
which holds the fi rebox in place.
4. Slide the fi rebox out of the outer can.
5. Remove the 2 pallet lag bolts.
Firebox
Timer Assembly
Outer Can
Phillips Head Bolts
Pallet
Lag
Bolts
Flue Collar
Attachment Bar
Figure 38.2