
Page 16
7044-140C
November 21, 2011
R
3100-I ACC Wood Insert
Q. Opacity (Smoke)
Opacity is the measure of how cleanly your appliance is
burning.
Opacity is measured in percent:
•
100% opacity is when an object is totally obscured by
the smoke column from a chimney, and
• 0% opacity means that no smoke column can be seen.
As you become familiar with your appliance, you should
periodically check the opacity. This will allow you to know
how to burn as nearly smoke-free as possible (goal of 0%
opacity).
P. Frequently Asked Questions
ISSUES
SOLUTIONS
Odor from appliance
When fi rst operated, this appliance may release an odor for the fi rst several hours. This is
caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the appliance.
Whirring sound
The blower may produce a whirring sound which increases in volume as the speed is
increased.
Figure 16.1 - Clear Space
O. Clear Space
• Do NOT place combustible objects within 4 ft (1.2 m) of
the front of fi replace.
Figure 16.1
.
•
Do NOT place combustible objects within 48
inches in front of the appliance.
•
High temperatures may ignite clothing, furniture or
draperies.
Fire Risk.
WARNING
CLE
AR
SP
AC
E
4 F
T (1
.2m)
IN
FR
ON
T O
F IN
SER
T
NOTICE!
Do NOT operate a circulating fan within close prox-
imity, approximately 4 ft (1.2m), of appliance
• Can reverse air fl ow, blowing hot air into appli-
ance cavity.
• Can damage appliance blower due to overheat-
ing.
R. Door Closing
To operate this unit the way it was designed by the manu-
facturer, the door must be sealed. To seal the unit, the front
door needs to remain closed during operation.
•
Grasp metal spring on front door and push door
closed.
•
With your hand on the handle of the door, rotate the
handle clockwise, until it will no longer rotate in that
direction.
•
This will ensure that the door is properly closed, and will
not allow for any air leakage.
DO NOT operate this unit with the fi rebox door open for
a continuous period of time.
This appliance was tested to manufacturers
specifi cations and operating this unit in a matter other
than specifi ed by the manufacturer will effect the
effi ciency of this unit.
WARNING