1.  Remove ash removal system top and

bottom cover plates by loosening nuts
under stove.

2.  Discard both plates.
3.  Insert ash removal system grate  into

opening in firebox floor.

4.  Continue with proper installation

according to model you have purchased:
pedestal or leg.

ASH REMOVAL SYSTEM INSTALLATION

1.  Place protective pad or stove pallet on floor.
2.  Lay body of stove on its back on protective

pad or pallet.

3.  Line up holes in ash removal system with

holes in adapter on bottom of stove.

4.  Screw ash removal system securely in place.
5.  Slide pedestal over ash removal system, and

line up holes in sides of pedestal with holes
in adapter on bottom of stove.

6.  Screw pedestal into place, and tighten

securely.

7.  Carefully stand stove up and place in desired

location.

8.  Slip wooden decorative strips onto pedestal

edges.

9.  Open door of stove and check to insure

firebricks and kaowool blanket are in
their proper locations (see pages 25-26).

PEDESTAL MODEL

LEG MODEL

1.   Place protective pad or stove pallet on floor.
2.   Lay body of stove on its back on protective

pad or pallet.

3.   Line up holes in ash removal system  with

holes in adapter on bottom of stove.

4.   Screw ash removal system in place.
5.   Bolt cover pieces onto mounting brackets,

using outer two mounting holes.

6.   Slip washers onto bolts, then bolt legs onto

mounting brackets.

7.   Screw leg assembly onto adapter on bottom

of stove using eig

ht ¼”

-20 screws.

8.   Carefully stand stove up and place in

desired location.

9.   Use leveling bolts on legs to stabilize and

level stove.

10. Open door of stove and check to insure

firebricks and kaowool blanket are in
their proper locations (see pages 25-26).

Summary of Contents for 3100 Series

Page 1: ...unit to a chimney flue already serving another appliance 10 Comply with all minimum clearances to combustibles as shown in this manual for this appliance 11 Build fire on brick firebox floor Do not us...

Page 2: ...h removal system installation 18 Ash removal system operating and cleaning 19 Operating instructions 20 Burning process 20 Primary and secondary air systems 20 Blower operating instructions 21 Operati...

Page 3: ...3100 SAFETY LABEL found on back of stove Page 3 Manufactaured by Model Quadra Fire 3100 Serial No...

Page 4: ...24 1 2 622mm 9 229mm 21 1 2 546mm 2 1 4 57mm 23 584mm DIMENSIONS Page 4 FIGURE 1b FIGURE 1a 20 1 2 521mm 9 229mm 24 1 2 622mm 2 1 4 57m m 23 584mm 26 3 8 670mm LEG MODEL PEDESTAL MODEL...

Page 5: ...m 4 5 16 110m m 24 5 8 626m m 25 635m m 9 229m m 2 13 16 72m m 21 1 2 546m m STEP TOP LEG MODEL 13 11 16 348m m 4 5 16 110m m 26 5 8 676m m 23 7 8 606m m 2 13 16 72m m 24 5 8 626m m 20 1 2 521m m 21...

Page 6: ...For installations with a preexisting class A chimney system a listed stainless steel chimney liner should be installed or the existing chimney examined by a chimney sweep for acceptable further use N...

Page 7: ...all at least one smoke detector on each floor of your home to ensure your safety They should be located away from the heating appliance and close to the sleeping areas Follow the smoke detector manufa...

Page 8: ...p of the stove after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations Your Quadra Fire stove was designed for and tested on...

Page 9: ...the spaces where the chimney passes through floors and or ceiling Figure 5 The chimney must have a fire clay flue liner or equivalent with a minimum thickness of 5 8 16mm and must be installed with r...

Page 10: ...hest point where it passes through the roof and at least 2 610mm higher than the highest part of the roof or structure that is within 10 3048mm of the chimney measured horizontally Figure 7 Remember t...

Page 11: ...imbles must be strictly followed to assure the safety of the system Be sure to maintain the designated clearances to combustible materials A BRICK CHIMNEY THIMBLE ASSEMBLY Construction of the brick th...

Page 12: ...mm long section of prefabricated listed solid pack chimney to use as a thimble Purchase a wall spacer trim collar and wall band that are manufactured to fit the chimney section you purchase Cut out a...

Page 13: ...eyond the edge of the chimney flue lining Apply high temperature furnace cement to the end of the chimney section and install it over the connector through the wall band and through the wall spacer Ti...

Page 14: ...ll an exterior chimney that runs up the outside of the residence Figure 13 This method of installation requires at a minimum a wall pass through device a wall support package insulated T section and r...

Page 15: ...ved grounding device 6 Refer to clearance to combustibles section page 6 for listing to combustibles 7 Seal all wall floor inlets to prevent air or moisture penetration Check periodically to insure th...

Page 16: ...w ash lip with two 20 mounting screws 2 Mount rear air intake cover plate with two mounting screws 3 Install each side cover with two 8 32 screws 4 Floor installation Cut a 3 76mm minimum hole in the...

Page 17: ...tective pad or pallet 3 Bolt cover piece onto mounting brackets using outer two mounting holes 4 Slip washers onto bolts then bolt legs onto mounting brackets 5 Screw leg assembly onto adapter on bott...

Page 18: ...ly stand stove up and place in desired location 8 Slip wooden decorative strips onto pedestal edges 9 Open door of stove and check to insure firebricks and kaowool blanket are in their proper location...

Page 19: ...stem grate into the drawer below If there are large pieces in the ashes you can remove the grate before cleaning the ash into the drawer Be sure to replace the grate before operating the stove 3 Relea...

Page 20: ...ained and not allowed to go out This will insure the cleanest possible fire If you are adjusting your stove for a low burn rate you should close down the air to the point where you can still maintain...

Page 21: ...um of 15 minutes 2 Regulate burn rate heat output by using the secondary control center under ashcatcher The primary control on the right is mainly for initial start up reloading or high burns 3 Heat...

Page 22: ...to allow adequate air flow between them 7 When ready to reload the stove add more logs Large logs burn slowly holding a fire longer Small logs burn fast and hot giving quick heat 8 Adjust the primary...

Page 23: ...on removable film on inside of glass Overfiring voids warranty NOTE Replace with ceramic glass only CARE AND CLEANING OF PLATED SURFACES Clean 24 karat gold plated surfaces with vinegar or a glass cle...

Page 24: ...rame pieces over the fiberglass tape on the edges of the glass Be sure glass is centered in the opening i e same space top and bottom left and right sides 6 Reinstall screws and glass tabs tight enoug...

Page 25: ...ve the firebrick from the sides of the stove 4 With a 3 16 allen wrench remove the secondary combustion tube retainer bolts on the secondary air channel under the end of each tube NOTE Soak the bolts...

Page 26: ...2 through 7 in reverse Be sure that the hole in the baffle is on its alignment pin on the rear shelf 7 Keep the baffle tilted as you lift it out the door BAFFLE REMOVAL AND INSTALLATION cont Page 26...

Page 27: ...r this unit is adjusted at the factory and should not require further adjustment When the speed control is turned clockwise it will click on to high speed Turn the speed control clockwise to decrease...

Page 28: ...S clips to the upper edge of the outer wall of the stove 3 Set top heat shield on stove and push down into S clips 4 Install chimney pipe through hole in top heat shield NOTE SEE PAGE 6 FOR REDUCED CL...

Page 29: ...32 1911 Trim door 832 0031 Gold door 831 1670 Ash removal system SERVICE PARTS 832 0420 Kaowool blanket 832 3010 Firebox brick set clay 3100 Unibody 3100 ARS 832 0550 Individual brick clay 832 0360 Ba...

Page 30: ...NOTES Page 30...

Page 31: ...NOTES Page 31...

Page 32: ...for any alteration to the unit which causes sooting that results in damage to the interior or exterior of the building in which this appliance is installed This warranty is void if the stove has been...

Reviews: