February 10, 2010
7044-140B
Page 4
3100-I ACC Wood Insert
R
Strain
Relief
Green Ground
Wire & Nut
Disconnect wires
from wire harness
Strain Relief
Green Ground
Wire & Nut
White (neutral) Wire
Male Spade
Terminal
Clip all 3 zip ties
Male Terminal
Female Terminal
Male Terminal Wire 5
inches (127mm) Longer
Speed
Control
Attach Female Terminal
to Black Wire
Figure 43.1
Figure 43.2
Figure 43.3
Figure 43.4
Figure 43.5
Relocating Blower Cord to Left Side
1. Remove the green ground terminal from the stud and
unhook the neutral (white) and line power wires from the
rest of the harness.
Figure 43.1
.
2. Re-install the nut on the stud after removal of the ground
terminal.
. Remove the strain relief from the side panel by gently
pressing in the tabs using needle nose pliers on the wire
harness side portion the strain relief.
4. Identify the wire with the male spade terminal (this was
originally connected to the white (neutral) lead on the
power cord) and carefully clip the three small zip ties
that connect it to the rest of the harness.
Figure 43.2
5. Once this wire is removed from the harness reverse
the wire so that the female spade terminal is pointing
towards the rest of the harness.
6. Re-attach this wire using the small zip ties supplied in
roughly the same locations that you removed earlier.
Leave the male spade terminal 5 inches (127mm) longer
than the female spade terminal that is already attached
to the harness.
Figure 43.3.
7. Attach the female spade terminal to the black wire that
comes out of the speed control.
Figure 43.4.
8. Route the long lead wires from the right side of the unit
in the wire channel that is under the unit.
9. Install the blower. See
page 42
for details.
10. On the left side panel attach the power cord strain relief
into the hole that is located on the lower left. Attach the
ground terminal to the stud that is located nearest the
power cord.
Figure 43.5.
11. Attach the white lead (neutral) directly to one of the
leads coming off the blower. Attach the other blower
lead to the female spade connector to the harness that
is routed under the unit. Attach the male spade con
-
nector on the harness to the black power wire (line).
Route the wires into the wire clip that is located on the
blower mount plate.
Figure 43.5.
12. Attach the left and right side panels.
K. Blower Cord Installation on Left Side
The blower cord is shipped to be installed on the right side
of the appliance. You may relocate the cord so it is on the
left side. You will need to remove the wires, flip them over
and remove and reverse the male and female terminals
and re-install the wires. The wire harness and components
are located on the back side of the right side panel.