background image

Page  2

7039-131H

May 5, 2011

R

2100 Millennium Wood Stove  (ACC)

Hearth & Home Technologies welcomes you to our tradi-

tion of excellence!  In choosing a Quadra-Fire appliance, 

you have our assurance of commitment to quality, durabil-

ity, and performance.
This commitment begins with our research of the market, 

including ‘Voice of the Customer’ contacts, ensuring we 

make products that will satisfy your needs. Our Research 

and Development facility then employs the world’s most 

advanced technology to achieve the optimum operation of 

our stoves, inserts and fireplaces.  And yet we are old-fash-

ioned when it comes to craftsmanship.  Each unit is meticu-

lously fabricated and surfaces are hand-finished for lasting 

beauty and enjoyment.  Our pledge to quality is completed 

as each model undergoes a quality control inspection.  
We wish you and your family many years of enjoyment in the 

warmth and comfort of your hearth appliance.  Thank you for 

choosing Quadra-Fire.

and Welcome to the Quadra-Fire Family

!

SPÉCIFICATIONS DE LA VENTILATION:

MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de 

minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en 

usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, 

ou une cheminée de briques, avec espaces libres référés.

MUR  DOUBLE:  De  six  (6  inches)  (152mm)  de  diamètre,  le  connecteur  du  conduit 

d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe 

"A, ou une cheminée de briques, avec espaces libres alloués.

MAISON  MOBILE:    Utiliser  un  conduit  de  mur  double  par  Dura-Vent  DVL,  Selkirk 

Metalbestos  DS  ou  Security  DL.  Doit  être  équipé  d'un  arrêt  d'étincelle.  Utiliser  les 

espaces libres pour mur double comme mentionné ci-bas.

MINIMUM CLEARANCES TO COMBUSTIBLES  In Inches & (Millimeters)

NOTE:  All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.

LISTED ROOM HEATER, SOLID FUEL TYPE.   

ALSO FOR USE IN MOBILE HOMES.  (UM) 84 HUD .  

"For Use with Solid Wood Fuel Only" 

1445 N. Highway, Colville, WA 99114

www.quadrafire.com

Install  and  use  only  in  accordance  with 

manufacturer's  installation  and  operating 

instructions.  Contact local building or fire officials 

about  restrictions  and  installation  inspections  in 

your  area.  Do  not  obstruct  the  space  beneath 

heater.

WARNING - For Mobile Homes

:  Do not install in 

a sleeping room.  An outside combustion air inlet 

must be provided and unrestricted while unit is in 

use.    The  structural  integrity  of  the  mobile  home 

floor,  ceiling  and  walls  must  be  maintained.   The 

stove needs to be properly grounded to the frame 

of  the  mobile  home.    Components  required  for 

mobile  home  installation:    Outside  Air  Kit,  Part 

Number 831-1780.

Refer  to  manufacturer's  instructions

  and  local 

codes  for  precautions  required  for  passing 

chimney through a combustible wall or ceiling and 

maximum offsets.

Inspect  and  clean  chimney  frequently  -  Under 

Certain Conditions of Use, Creosote Buildup May 

Occur Rapidly.

Do  not  connect  this  unit  to  a  chimney  serving 

another appliance.

Optional  Components:    Optional  Blower,  Part 

831-1701.

Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz.

Route  power  cord  away  from  unit.    Do  not  route 

cord under or in front of appliance.

DANGER: Risk of electrical shock.

  Disconnect 

power supply before servicing.

Replace  glass  only  with  5mm  ceramic  available 

from your dealer.

Do not use grate or elevate fire.  Build wood fire 

directly on hearth.

Do  not  overfire  -  if  heater  or  chimney  connector 

glows, you are overfiring.

Operate  only  with  the  fuel  loading  door  closed.  

Open only to add fuel to the fire.

CAUTION

:

 

U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to 

comply with July 1990 particulate emission standards.

2009  2010  2011  Jan.  Feb.  Mar.  Apr.  May  June July  Aug. Sept. Oct.  Nov.  Dec.

PREVENT HOUSE FIRES

   

FLOOR PROTECTION

:

Floor  protector  must  be  a  3/8  inch  min.  thickness, 

non-combustible  material  or  equivalent,  extending 

beneath heater and to front/sides/rear as indicated 

on the diagram below. 

Exception:

 Non-combustible 

floor protections must extend beneath the flue pipe 

when installed with horizontal venting and extend 2 

inches  (51mm) beyond each side.  

Report / Rapport

061-S-70-6

TESTED TO:/ TESTÉ À:

   UL 1482,  ULC S627-00. 

Manufactured by:

HOT  WHILE  IN  OPERATION  DO  NOT  TOUCH,  KEEP  CHILDREN AND  CLOTHING AWAY.  CONTACT  MAY  CAUSE  SKIN  BURNS.    KEEP 

FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS

 

SINGLE WALL PIPE

 

15 (381)  11 (279)  21.5 (546)  13 (330)  8.5 (216)  17 (432)  56 (1422) 

N/A

DOUBLE WALL PIPE

 

8.75 (222)  5.75 (146)  20 (508)  10.5 (267)  7.5 (191)  16 (406)  43 (1092) 

N/A

SINGLE WALL PIPE     

  

14 (356)  10 (254)  20.5 (521)  12 (305)  8.5 (216)  17 (432)  56 (1422)  9.5 (241)

 

DOUBLE WALL PIPE

 

9.5 (241)  5.5 (140)  21.5 (546)  13 (330)  7.5 (191)  16 (406)  43 (1092)  5 (127)

INSTALLATION: ALCOVE

 - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built 

Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 

inches (1220mm) with a minimum height of 43 inches (1092mm) to top of unit, and the referenced clearances.

DOUBLE WALL PIPE

 

     9.5 (241)   5.5 (140)  21.5 (572)  13.5 (343) 

N/A 

N/A          43 (1092)    5 (127)

VENT SPECIFICATIONS:

SINGLE  WALL:

  Six  inch  (6  inches)  (152mm)  diameter,  minimum  24  MSG  black  or 

blued  steel  connector  pipe,  with  a  listed  factory-built  UL103HT*  Class  "A"  chimney, 
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.

DOUBLE  WALL:

  Six  inch  (6  inches)  (152mm)  diameter,  listed  double  wall  air 

insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or  a 
masonry chimney and the referenced clearances

*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree 

Factory-built chimneys.

MOBILE HOME:

  Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or 

Security  DL  double  wall  connector  pipe.  Must  be  equipped  with  a  spark  arrestor.  
Apply double wall clearances below when installing unit.

SERIAL NO.

 / NUMÉRO DE SÉRIE

2100 Millennium ACC

  

A

B

C

D

E

F

E

F

G

G

A

B

C

D

R

7039-134

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION:

APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE 

COMBUSTIBLE SOLIDE, POUR USAGE DANS LES 

MAISONS MOBILES. (UM) 84-64 HUD. "Pour Usage 

Avec Bois Solide Seulement"

Installez  et  utilisez  en  accord  avec  les  instructions 

d'installation et d'opération du fabricant. Contactez le bureau 

de la construction ou le bureau des incendies au sujet des 

restrictions  et  des  inspections  d'installation  dans  votre 

voisinage. Ne pas obstruez l'espace en dessous de l'appareil.

AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une 

chambre à coucher. Un tuyau extérieur de combustion d'air 

doit être installé et ne doit pas être obstrué lorsque l'appareil 

est en usage. La structure intégrale du plancher, du plafond et 

des  murs  de  la  maison  mobile  doit  être  maintenue  intacte. 

L'appareil  de  chauffage  doit  être  fixé  à  la  charpente  de  la 

maison mobile. Les composants requis pour l'installation des 

maisons  mobiles: Assemblage  d'air  extérieur,  Numéro  de 

Pièce 831-1780.

Référez  vous  aux  instructions  du  fabricant  et  des  codes 

locaux  pour  les  précautions  requises  pour  passer  une 

cheminée à travers un mur ou un plafond combustibles, et les 

compensations maximums.

Inspectez  et  nettoyez  la  cheminée  fréquemment.  Sous 

certaines  conditions,  il  se  peut  que  la  créosote  s'accumule 

rapidement.

Ne  pas  connecter  cet  appareil  à  une  cheminée  servant  un 

autre appareil.

Composants  Optionnels:  Ventilateur  Optionnel,  Pièce 

#831-1701.

Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.

Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil 

électrique au dessus ou en dessous de l'appareil.

DANGER: Il y a risque de décharge électrique.  Déconnectez 

le fil électrique de la prise de contact avant le service.

Remplacez la vitre seulement avec une vitre céramique de 5 

mm disponible chez votre fournisseur.

N'élevez pas le feu. Bâtissez le feu de bois directement sur 

l'âtre.

Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de 

cheminée rougissent, vous surchauffez.

Opérez l'appareil seulement lorsque la porte de chargement 

est  fermée.  Ouvrez  la  porte  seulement  lorsque  vous  devez 

ajouter des combustibles dans le feu.

PRÉVENTION DES FEUX DE MAISON

PROTECTION DU PLANCHER

:

Le protecteur de plancher doit être d'un minimum de 3/8 inch 

d'épaisseur,  de  matériel  incombustible  ou  équivalent, 

s'étendant du dessous de l'appareil de chauffage à l'avant, 

aux  cotés  et  à  l'arrière  comme  indiqué  sur  le  diagramme 

suivant.  Exception:  Les  protections  incombustibles  du 

plancher  doivent  s'étendre  en  dessous  du  conduit  de 

cheminée lorsqu'installées avec une ventilation à l'horizontale 

et s'étendre de 2 inches (51mm) de chaque côté.  

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces & 

(millimètres)

NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de 

l'entrée du conduit.

BACKWALL/SIDEWALL

MUR ARRIÈRE/MUR DE CÔTÉ 

STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU PLAFOND 

CORNER INSTALLATION

INSTALLATION DU COIN 

ALCOVE TOP VIEW /

VUE DU HAUT DE L'ALCÔVE 

ALCOVE SIDE VIEW / 

VUE DE CÔTÉ DE L'ALCÔVE

CONDUIT DU MUR SIMPLE

CONDUIT DU MUR SIMPLE

C

ONDUIT DU MUR DOUBLE

CONDUIT DU MUR DOUBLE

INSTALLATION: FULL VERTICAL / ENTIÈREMENT VERTICALE  

INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP

INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE

I

NSTALLATION: ALCÔVE - De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine 103HT de Classe "A", ou une 

cheminée de briques. (Les maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48 inches (1220mm) avec une 

hauteur minimum de 43 inches (1092mm) du haut de l'appareil, et des espaces libres alloués. 

CONDUIT DU MUR DOUBLE

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A./Fait Aux États-Unis

*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée 

bâtit en usine.

Fabriqué par:

007004

16" from glass

8 in.

USA

Fuel loading door

5-3/4 in.

2-1/4 in."

29-5/8 in.

minimum

36 in.

minimum

CANADA

203mm (8 in.)

203mm

(8 in.)

203mm

(8 in.)

457mm (18 in.)

1332mm 

(52-7/16  in.)

minimum

1000mm (38-3/8 in.)

minimum

O-T L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION:  BACK OF APPLIANCE

Serial No.

Model 

Name

Test Lab & 

Report No.

Mfg. Date

S A

M P

L E

NOTE:  Clearances may only be 

reduced by means approved by the 

regulatory authority having jurisdiction

Summary of Contents for 2100 Millennium

Page 1: ...ances to combustibles as specified Failure to comply may cause house fire Fire Risk WARNING For use with solid wood fuel only Other fuels may overfire and generate poisonous gases i e carbon monoxide Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies recommends NFI certified professionals or technicians supervised by an NFI certified prof...

Page 2: ...pe with a listed factory built UL103HT Class A chimney suitable for use with solid fuels or a masonry chimney and the referenced clearances DOUBLE WALL Six inch 6 inches 152mm diameter listed double wall air insulated connector pipe with listed factory built UL103HT Class A chimney or a masonry chimney and the referenced clearances In Canada must comply with Standard CAN ULC S629 M87 for the 650 d...

Page 3: ...iance 20 B Wood Selection Storage 20 C Burning Process 20 21 D Automatic Combustion Control ACC 21 E Air Controls 21 22 F Burn Rates Operating Efficiency 22 G Building A Fire 23 H Correct Baffle Blanket Placement 24 I Blower Operating Instructions 25 J Opacity Smoke 25 K Frequently Asked Questions 26 Section 9 Maintaining Servicing Appliance A Quick Reference Maintenance Guide 27 B General Mainten...

Page 4: ...he right to alter its products their specifications and or price without notice Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or your dealer Quadra Fire is a registered trademark of Hearth Home Technologies Installation and use of any damaged appliance Modi...

Page 5: ...sisting of at least two escape routes 4 A plan to deal with a chimney fire as follows In the event of a chimney fire a Evacuate the house immediately b Notify fire department WARNING DO NOT CONNECT THIS UNIT TO A CHIM NEY FLUE SERVICING ANOTHER APPLI ANCE DO NOT CONNECT TO ANY AIR DISTRIBU TION DUCT OR SYSTEM May allow flue gases to enter the house Asphyxiation Risk Fire Risk WARNING Do not operat...

Page 6: ... include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water heaters and other combustion appliances Clothes dryers Location of return air vents to furnace or air condi tioning Imbalances of HVAC air handling system Upper level air leaks Recessed lighting Attic hatch opening Duct leaks To minimize the affects of negative air pressure the following must be consi...

Page 7: ...bove the top of the appliance after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations F Tools And Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Reciprocating saw Pliers Hammer Phillips Head Screwdriver Flat Blade Screwdriver Plumb Line Level Tape Measu...

Page 8: ...Termination Cap Outside Air Rear Vent Spark Arrestor Cap Floor Protector Chimney Connector Ceiling Support Listed Chimney Listed Termination Cap Storm Collar Flashing Figure 8 3 Interior Prefabricated Chimney Figure 8 2 Exterior Prefabricated Chimney Figure 8 1 Masonry Chimney H Typical Stove Systems Stove system with masonry chimney consists of Stove Chimney Connector stove pipe Thimble Masonry C...

Page 9: ...mm 16 in 406mm 11 1 2 in 292mm 20 3 4 in 527mm C L C L 4 1 2 in 108mm Outside Air Connection A Appliance Dimensions Figure 9 1 Front View Figure 9 2 Side View NOTE Flue Collar size is 6 inch 152mm diameter ID 12 3 4 in 324mm 23 3 8 in 594mm 8 5 8 in 219mm 11 11 16 in 297mm 27 15 16 in 709mm 13 1 2 in 342mm 9 1 4 in 235mm 17 in 432mm C L ...

Page 10: ...d by the regulatory authority having jurisdiction Fire Risk Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING NOTE Service Space In order to replace the tube channel assembly a clearance of 17 inches 432mm is required on the right side of stove in order to remove the tubes with the stove in place If space is not available the stove will ...

Page 11: ... 39 in minimum 2 9 5 8 i n 2 5 3 8 i n 32 7 8 in 3 9 i n 3 in 1 3 5 o p t i o n a l c o v e r a g e 50 3 4 in Must extend 2 in 51mm beyond each side of pipe shaded area 203mm 8 in 203mm 8 in 203mm 8 in 457mm 18 in 1244mm 49 in minimum 1000mm 39 3 8 in minimum In Canada similar floor protection must be provided 18 inches 457mm in front and 8 inches 203mm from the sides and rear of the stove See exc...

Page 12: ...ssary in order for combus tion to take place Whatever combustion air is consumed by the fire must be replaced Air is replaced via air leakage around windows and under doors In homes that have tightly sealed doors and windows an outside air source is needed An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex Adapter Termination Cap For Floor Installa tions Remove Circular Knoc...

Page 13: ...the bottom left rear corner as shown in Figure 13 1 See page 25 for detailed operating instructions for the blower and snap disc Figure 13 1 Shock Risk Do NOT remove grounding prong from plug Plug directly into properly grounded 3 prong receptacle Route cord away from appliance Do NOT route cord under or in front of appliance CAUTION MANUAL Over rides the Snap Disc AUTO Fan will turn ON OFF Automa...

Page 14: ...steel black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connector passes to the chimney It is intended to keep the walls from igniting Site constructed thimbles must meet NFPA 211 Standards Prefabricated must be suitable for use with selected chimney and meet...

Page 15: ...aming lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 15 1 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wall opening The spacer should be on the chimney side 6 Insert the section of the solid insulated chimney into the outer wall of the masonry chimney 7 Tightly secure the length of the sol...

Page 16: ...tors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Stove Secure pipe sections with a minimum of 3 screws Figure 16 2 Chimney Connector Stove Pipe WARNING DO NOT CONNECT THIS UNIT TO A CHIM NEY FLUE SERVICING ANOTHER APPLI ANCE DO NOT CONNECT TO ANY AIR DISTRI BUTION DUCT OR SYSTEM May allow flue gases to enter the house Asphyxiation Risk Improper ...

Page 17: ...e roof within 10 feet 305cm Must be located away from trees or other struc tures These are safety requirements and are not meant to assure proper flue draft Figure 17 1 E 2 10 3 Rule Figure 17 2 NOTE Chimney performance may vary Trees buildings roof lines and wind conditions affect performance Chimney height may need adjustment if smoking or overdraft occurs 3 ft 91cm Minimum Less than 10 ft 305cm...

Page 18: ...manufacturer s instructions when installing the flue system for use in a mobile home 7 Maintain clearance to combustibles 8 Floor protection requirements must be followed precisely 9 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure You must use a Quadra Fire Outside Air Kit Part OAK ACC and depending ...

Page 19: ...uire further adjustment B Adjusting The Blower Speed Control A Door Handle Assembly 1 Install washer on door handle shaft 2 Slide door handle through door 3 Install second washer s as shown in Figure 19 1 4 Install key in groove 5 Align groove in latch cam with key slide latch cam over shaft 6 Install locknut but do not overtighten the handle needs to move smoothly 7 Install spring handle turning ...

Page 20: ...d establishing the flue draft not evaporating the moisture out of wet unseasoned wood resulting in wasted heat Do not over fire Over firing may ignite creosote or will damage the stove and chimney To prevent over firing your stove DO NOT Use flammable liquids Overload with wood Burn trash or large amounts of scrap lumber Permit too much air to the fire WARNING Fire Risk Symptoms of over firing may...

Page 21: ...his function is performed by sliding the con trol all the way back until it stops at the HI indicator on the label and then pulling forward to the front of the stove until it stops This activates the ACC system and opens the front air channel and allows air to enter the front of the stove for approximately 25 minutes The front air channel gradually shuts down until it is completely closed at the e...

Page 22: ...his air is regulated by the Burn RateAir Control There are four settings High Medium High Medium Low and Low When the control is raised all the way up it is on the High setting and when pushed all the down it is on the Low setting Figure 22 1 NOTE These are approximate settings and will vary with type of wood or chimney draft Due to altitude and other environmental circumstances this operational i...

Page 23: ...other the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7 Set the Burn Rate Air Control and activate the timer system ACC 8 When ready to reload It is best to fully open both the Burn Rate Air and Start up Air Controls before reload ing This livens up the coalbed and reduces excessive emissions...

Page 24: ...cement and replace baffle com ponents if damaged or missing H Correct Baffle Blanket Placement Ceramic Blanket and Baffle Board are NOT in contact with the back of the firebox Ceramic Blanket is NOT in contact with the back of the firebox and NOT even with the Baffle Board in the front Ceramic Blanket is bunched up at the back of the firebox and NOT even with the Baffle Board in the front Ceramic ...

Page 25: ... the snap disc with the manual over ride knob See page 13 2 The blower is equipped with a speed control Adjust the fan speed by turning the speed control clockwise to Low or counterclockwise to High 3 Snap Disc Location If you find the blower coming on and off at undesirable temperatures relocate the snap disc to another location in the designated zone on the back of the appliance Figure 25 1 Ther...

Page 26: ...Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance Whirring sound If the optional blower has been installed the blower produces a whirring sound which increases in volume as the speed is increased Odors and vapors released during initial op...

Page 27: ...blockage poor draft and chimney fires Always burn dry wood to help prevent cap blockage and creosote build up Keeping the door and glass gasket in good shape will maintain good burn times on a low burn setting Check the glass frame for loose screws to prevent air leakage Check the door latch for proper adjustment This is very important especially after the door rope has formed to the stove face St...

Page 28: ...hes Fire Risk Disposal of Ashes WARNING Ashes should be placed in metal container with tight fitting lid Do not place metal container on combustible surface Ashes should be retained in closed container until all cinders have thoroughly cooled Fire Risk Do not use chimney cleaners or flame colo rants in your appliance Will corrode pipe WARNING Fire Risk Prevent creosote buildup WARNING Inspect chim...

Page 29: ...O NOT OVERTIGHTEN 9 Replace the door on the appliance Quadra Fire stoves are equipped with ceramic super heat resistant glass which can only be broken by impact or misuse Do not slam stove door or impact the glass When closing door make sure that logs do not protrude against the glass Inspect glass regularly If you find a crack or break immediately put the fire out and return the door to your deal...

Page 30: ...bottom bricks in unit 4 Install rear bricks on the top of the bottom bricks Slide top of bricks under clip on back of firebox wall and push bottom of brick back 5 Install side bricks Slide top of brick under clips on side of firebox and push the bottom of the brick until it is flush with the side of the unit D Firebrick Replacement Use Part 832 0550 when ordering individual brick Provide brick dim...

Page 31: ... first Figure 31 2 Place on top of baffle board open up and flatten and smooth out the blanket Re check the baffle board for correct positioning Figure 23 1 on page 23 and page 24 Figure 31 1 Baffle Figure 31 2 Ceramic Blanket F Snap Disc Replacement Snap Disc Magnet Spade Connectors Figure 31 3 1 Locate the snap disc bracket assembly at the bottom left rear corner of the stove Figure 31 3 2 A mag...

Page 32: ...he tube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 3 Make sure tube channel assembly is flush against the side of the stove and secure with channel nuts 4 Re install channel cover and side shield Tube Channel Rack Channel Access Cover Channel Cover Screws 4 Channel Nuts 2 Tube Channel Assembly Si...

Page 33: ... fire section Check for adequate vent height refer to chimney assembly section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to wood fuel section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to starting fire section Flue blockage such as birds nests or leaves in terminati...

Page 34: ...ood Stove ACC Service Parts 04 11 R 21M ACC Part number list on following pages 2100 Millennium Wood Stove Advanced Combustion Control ACC 1 2 3 4 5 6 7 8 9 10 11 12 14 16 15 13 Beginning Manufacturing Date July 2007 Ending Manufacturing Date Active ...

Page 35: ...039 003 4 Brick Assembly Complete Set SRV7039 007 4 1 Brick 9 x 4 1 2 x 1 1 4 Qty 9 Req 4 2 Brick 6 x 4 1 2 x 1 1 4 Qty 3 Req 4 3 Brick 8 x 4 1 2 x 1 1 4 Qty 2 Req 4 4 Brick see diagram Qty 1 Req 4 5 Brick see diagram Qty 1 Req Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 5 Tube Support Rack SRV7039 108 6 Brick Retainer 7033 149 7 Ceramic Fiber Blanket 1 2 Thick 832 3390 Y 8 Baffle Board 8 1 8 ...

Page 36: ...bly 7033 034 Y 16 10 Door Gasket Front Rear Air Timer Doors 7033 282 Y 17 1 Door Assembly Black SRV7039 008 17 2 Hinge Pins 1 2 Gold 832 0250 Nickel 430 5320 Black 7000 606 2 17 3 Spring Handle 1 2 Nickel Pre SN 0070040260 250 8330 Y Spring Handle 1 2 Gold 832 0620 Y Spring Handle 1 2 Black Post SN 0070040260 SRV7000 613 Y 17 4 Door Handle Only 430 1131 17 5 Glass Assembly 14 1 8 in W x 9 13 16 in...

Page 37: ...ower Assembly BK ACC Blower Control Box W Switch SRV7000 194 Y Blower Convection 812 4900 Y Component Pack 7033 051 Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness Blower 7033 262 Gasket Manifold Pkg of 4 7038 168 4 Y Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly 7033 039 Outside Air Shield 33271 Y Upgrade Door Nickel Handles Hinge Pins...

Page 38: ...Page 38 7039 131H May 5 2011 R 2100 Millennium Wood Stove ACC Date of Service Performed By Description of Service C Service And Maintenance Log ...

Page 39: ...May 5 2011 7039 131H Page 39 2100 Millennium Wood Stove ACC R C Service And Maintenance Log Cont d Date of Service Performed By Description of Service ...

Page 40: ...Page 40 7039 131H May 5 2011 R 2100 Millennium Wood Stove ACC D Homeowner s Notes ...

Page 41: ...May 5 2011 7039 131H Page 41 2100 Millennium Wood Stove ACC R D Homeowner s Notes ...

Page 42: ...Page 42 7039 131H May 5 2011 R 2100 Millennium Wood Stove ACC E Warranty Policy ...

Page 43: ...May 5 2011 7039 131H Page 43 2100 Millennium Wood Stove ACC R ...

Page 44: ...145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6863064 6866205 6869278 6875012 6880275 6908039 6919884 D320652 D445174 D462436 Canada 1297749 2195264 2225408 2313972 Australia 780250 780403 1418504 or other U S and foreign patents pending Date purchased instal...

Reviews: