Owner and Installation Manual For: 

 

EZ-4000 

 

LOW ENERGY AUTOMATIC SWING 

DOOR OPERATOR 

 
 
 
 

PLEASE READ THIS ENTIRE MANUAL AND FOLLOW ALL 

GUIDELINES TO ENSURE PROPER INSTALLATION AND 

SAFETY 

 

PROUDLY DISTRIBUTED BY… 

 

 
 

 
 

REV. 12_6_16

 

Summary of Contents for EZ-4000

Page 1: ... and Installation Manual For EZ 4000 LOW ENERGY AUTOMATIC SWING DOOR OPERATOR PLEASE READ THIS ENTIRE MANUAL AND FOLLOW ALL GUIDELINES TO ENSURE PROPER INSTALLATION AND SAFETY PROUDLY DISTRIBUTED BY REV 12_6_16 ...

Page 2: ...rn slowly to the stop position if wired correctly 4 Plug in power supply Turn HOA switch to the HOLD position The motor should open to the full hard stop position 5 Install arm and check the outside cam The cam switch should be in the down position flat part of cam 6 Turn power off and let door close completely Check inside cam The switch should be in the down position flat part of cam 7 Turn powe...

Page 3: ...or system in compliance with the industry standards for safety It is your responsibility as owner or caretaker of the equipment to inspect the operation of your door system on a daily basis and after any loss of electrical power to ensure that it is safe for use by your invitees customers or employees Daily Safety Checks are the responsibility of the equipment owner or caretaker The Following safe...

Page 4: ... shall not apply to such products which have been altered or repaired by other than an authorized agent Authorization shall be in writing by Quad Systems LLC Warranty does not apply if products have been subject to misuse negligence or accident There is no expressed or implied warranty by Quad Systems LLC except as specifically stated above Quad Systems LLC shall not be liable for special or conse...

Page 5: ...cessibility All switching devices must be in sight of the door it operates 120 volt electrical supply supplied by others in accordance with all local codes This unit must be grounded Do NOT connect opener to source of power until instructed to do so Step One Mounting the Header Make sure the mounting area has proper support for the unit Wood studs or blocking in wallboard is recommended On each si...

Page 6: ... the motor until the Controller is installed and plugged in or serious damage could be inflicted on the Controller as well as the installer Install the Hold Open Automatic HOA switch into the end cap hole provided on each end and plug in wiring harness from switch and operator into marked pins WARNING Do NOT connect opener to source of power until instructed to do so NOTE At this point do not inst...

Page 7: ... 11 28cm 16 41cm 20 52cm 4 102mm 17 43cm 12 30cm 17 43cm 20 52cm REVEAL CENTER PIVOT 2 INSWING OUTSWING DIM A DIM B DIM A DIM B 0 17 43cm 9 23cm 16 41cm 16 42cm 13mm 17 43cm 9 23cm 16 41cm 17 43cm 1 25mm 17 44cm 9 23cm 16 41cm 17 44cm 1 38mm 17 44cm 9 23cm 16 41cm 17 45cm 2 51mm 18 45cm 10 25cm 16 41cm 18 47cm 2 63mm 19 48cm 10 27cm 17 43cm 19 48cm 3 76mm 19 48cm 10 27cm 18 45cm 20 51cm 3 89mm 19 ...

Page 8: ... 8 In Swing Out Swing ...

Page 9: ...ration must never be permitted with the control removed 1 0 Wiring On Off Switch and Incoming Power If the installation consists of a synchronized pair of operators see the special note on page 5 Install the supplied on off hold switch in the desired location and route the switch lace into the header Plug the connector into SWTCH input CN4 on the control Verify that the circuit breaker in the AC p...

Page 10: ...e to the current value of that parameter While continuing to hold the SET button use the UP or DOWN buttons to find the new value you wish to use When you ve found it release the SET button Switch the door back on and check the operation using the new value s Refer to Section 1 7 Parameter List for descriptions of the parameters and their factory defaults Note You may also access the parameter men...

Page 11: ...ch is in the ON position If the door tries to open insure that the rocker switch is not in the HOLD position instead of the ON position Cycle the door by pressing and holding the DOWN button this button functions as an actuate signal when the door is in normal operation allowing easier testing The door should cycle open The display will show OS Open Speed before the open check switch releases It w...

Page 12: ...arameter List before attempting operation with a lock Do not attempt to power the lock from the control unless the total accessory current draw including lock is 0 5A or less After all other devices are wired power the control back up and check for proper operation The green ACT ACTuate indicator should light whenever an external actuating device including the radio receiver triggers the door to o...

Page 13: ...delay begins when the door reduces speed to open check Possible values are 1 99 seconds and the setup default is 1 second d2 Time delay 2 push and go This delay is used only when the door has been actuated by a push and go signal The time delay begins when the door reduces speed to open check Possible values are 1 99 seconds and the setup default is 1 second Note d1 takes priority over d2 If the d...

Page 14: ...g as it prevents burn out or buzzing of inexpensive mortise type strikes If HS is turned on the lock will be held in the released condition for the total duration of the open cycle the close cycle and the latch check delay see the LC parameter Default is off do not hold strike through open cycle U1 3 User Parameters 1 3 These parameters adjust from 0 99 and are not used in any way by the control i...

Page 15: ... of roughly two times the given figure 0 82 amperes or 112 watts for any reasonable door weight up to 100 125 pounds The control has a 3 15 ampere fuse so in no case will the prolonged current draw be more than this figure as the fuse would blow Another question which seems to be asked frequently regards cost of operation It is estimated that the cost of operation is well below 0 01 per door cycle...

Page 16: ... 16 ...

Page 17: ... 17 ...

Page 18: ... 18 Lock with No Transformer not recommended Lock with Transformer recommended ...

Page 19: ...Quad System ES 500 control does not require a separate lockout relay as it has the lockout feature built in For maximum safety the BodyGuard memorizes two patterns covering the entire swing area when the door is closed and covering the swing area minus the area occupied by the door when the door is open In order to do this the BodyGuard needs to know when the door is open This is accomplished with...

Page 20: ... 20 BEA Technical Support East Region 866 836 1863 West Region 888 419 2564 ...

Page 21: ... 21 Optex Technical Support 800 966 7839 ...

Page 22: ... 22 Optex Technical Support 800 966 7839 904C ...

Page 23: ... 23 ...

Page 24: ...lation instructions Q How do I easily adjust the cams A Place switch on Hold Open position and let the door open to the full open position Loosen the small Allen head screws on the outside cam switch with 2 wires Rotate the cam until the switch is on the flat part of the cam and tighten screw Place switch in the Off o position and let the door close completely Loosen the small Allen head screws on...

Page 25: ...ontrol in a high energy mode this feature is supported beginning in Versions 1 02 1 03 An auxiliary harness Close Monitor harness part number 600 0008 01 will be required Set the AF parameter to 3 Wire the safety beam s output contact to the red and black wires of the auxiliary harness A beam break will prevent the door from opening if it s closed prevent it from closing if it s open slow the door...

Page 26: ... 26 ...

Reviews: