Qtx WINDMILL 150.550UK User Manual Download Page 5

 

150.550UK User Manual 

Control Menu Map 
 

 

 

DMX Protocol 
 

CH1 

Pan 

0-255: 0-540° 

CH2 

Pan Fine Adjustment  

0-255: Pan 

CH3 

Tilt1 

0-255: 0-360° 

CH4 

Tilt 1 Fine Adjustment 

0-255: Tilt 

CH5 

Tilt2 

0-255: 0-360° 

CH6 

Tilt2 Fine Adjustment 

0-255: Tilt  

CH7  

Pan Continuous Rotation 

0-55: No function 
56-127: Counterclockwise rotation 
128-199: Clockwise rotation 
200-255: No function 

CH8 

Tilt1 Continuous Rotation 

0-55: No function 
56-127: Counterclockwise rotation 
128-199: Clockwise rotation 
200-255: No function 

CH9 

Tilt2 Continuous Rotation 

0-55: No function 
56-127: Clockwise rotation 
128-199: Counterclockwise rotation 
200-255: No function 

CH10  

Pan Continuous Rotation speed/Pan 

speed 

0-254: From fast to slow 
255: No function 

CH11  

Tilt1 Continuous Rotation speed/ Tilt1 

speed 

0-254: From fast to slow 
255: No function 

CH12  

Tilt2 Continuous Rotation speed/ Tilt2 

speed 

0-254: From fast to slow 
255: No function 

Summary of Contents for WINDMILL 150.550UK

Page 1: ...WINDMILL LED MOVING HEAD LIGHT EFFECT Item ref 150 550UK User Manual...

Page 2: ...pairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorised technical assistance centre Make sure the power cord is never crimped or damaged Never dis...

Page 3: ...tures and equipment to be installed on it 2 Block access under the work area 3 Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket The bolt used mu...

Page 4: ...displayed The unit will now run to the beat of the music 3 The sound sensitivity can be adjusted by pressing the MENU button until SENE is displayed and then press ENTER Use the UP or DOWN buttons to...

Page 5: ...255 No function CH8 Tilt1 Continuous Rotation 0 55 No function 56 127 Counterclockwise rotation 128 199 Clockwise rotation 200 255 No function CH9 Tilt2 Continuous Rotation 0 55 No function 56 127 Cl...

Page 6: ...fter 3 seconds CH21 Reset 0 128 No function 129 255 RESET 28 Channels Mode Function Function Control CH1 Pan 0 255 0 540 CH2 Pan Fine Adjustment 0 255 Pan CH3 Tilt1 0 255 0 360 CH4 1 Fine Adjustment 0...

Page 7: ...White Head 1 0 255 0 100 CH20 Colour Macros Effects Head 2 0 10 No function 11 20 RED 21 30 GREEN 31 40 RED GREEN 41 50 BLUE 51 60 RED BLUE 61 70 GREEN BLUE 71 80 RED GREEN BLUE 81 123 Single colour...

Page 8: ...it to cool for at least 10 minutes 2 Unscrew the cap of the fuse holder and remove the fuse Replace with a fuse of the same size and rating only 3 Reinstall the fuse holder cap before re applying pow...