23
LOCATION RECOMMENDATIONS
QUANTUM® Securement System
• The QUANTUM® can be installed in the front, middle or back of the bus but MUST be near an accessible entrance and comply with local
transportation authorities—in regards to specific regulations, standards, requirements and minimum/maximum WMD location space and
emergency exit requirements.
• This is a rear-facing system.
66” (1676mm) Recommended
48” (1219mm) ADA
30” (762mm) ADA
.25” (6.35mm) Max Overhang
Flip-Up Seats
Bus Wall
28” (711mm)
Stowed
38” (965mm)
Fully Extended
Top View
30” (762mm) ADA
38” (965mm)
Fully Extended
Bus Wall
Flip-Up Seat
15.7” (399mm)
.25” (6.35mm)
Max Overhang
Front View
33” (838mm)
Side View
56” (1422mm)
Flip-Up Seats Not Shown
34” (864mm)
48” (1219mm) ADA
66” (1676mm) Recommended
13.75” (349mm)
48” (1219mm)
12” (304mm)
6” (152mm)
6” (152mm)
Mount Shoulder and Lap Belt Retractor on wall 48”
(1219mm) from floor, 6” (152mm) from Backrest Base and
within the 6” x 12” (152mm x 304mm) red rectangular space.