QSI Quantum 1 System Operation Manual Download Page 7

Analog Programming

The Electric Locomotive can be Programmed Using a Standard Power Pack.  

All advanced operations are easily programmed via your standard HO power pack. After entering programming (described below), features

are selected and operated by using the direction switch

17

Program

Option #’s

(POP’s

18

)

Option Name

Message

19

 when

Entering Option

Option Description

1

System Volume

20

 

(16, Max)

“Volume equals X”

Sets System volume (17 levels) where level 16 is maximum volume and level 0 is off. 

2

Load 

(0, No Load)

“Load equals X”

Selects the starting and stopping inertia for both Regulated Throttle Control (RTC) and
Standard Throttle Control (STC). 

 

Level 0 (no load), Level 1-15, increasing Load with

acceleration to full speed from 15 seconds to 210 seconds in RTC and from 3 seconds
to 45 seconds in STC. 

3

Helper 

(Normal)

“Helper equals”

“Normal”,

“Lead”,

“Mid” 

“End”

“Pusher”

Selects Normal, Lead, Mid, End, or Pusher Helper in consists. 
Normal Engine has all sounds and lights enabled.
Lead  engine  has  all  sounds  enabled  and  Reverse  Light,  reverse  Marker  Lights,
disabled. Cab Lights and Number Board Lights are unaffected. 
Mid Helper has Horn, Bell and all lights disabled

21

. Number Boards are unaffected.

End Helper has Horn, Bell and all lights disabled except Reverse Light, Marker Lights.
Number Board Lights are unaffected. 
Pusher has Reverse Light on and Reverse Marker Lights on red all the time as train
warning lights. Horn, Bell and all other lights are disabled. 

4

“Direction” (Normal)

“Direction equals X”

Selects if features associated with the locomotive’s direction are “Normal” or “Reverse”.

5-7

Reserved “Reserved”

8

V-Start (8.5v)

“V-Start equals X”

Sets track voltage where locomotive will leave Neutral. (See Example below)

9

V-Max (12v)

“V-Max equals X”

Sets track voltage where full power is applied to motor. 

10

Throttle Mode

(RTC)

“Throttle Mode

equals X””

Selects  between  Standard  Throttle  Control  (STC)  and  Regulated  Throttle  Control
(RTC).

11

Programming Reset

“Warning – about to

reset”

After  next  

Quick

 or  

Slow

  Operation,  Bell  rings

22

  followed  by  a  hoot  to  indicate

locomotive returned to factory default.  

12

About 

 Model number

Each  

Quick

 or  

Slow

  Operation  provides  progressive  information  about  Quantum

Model Number, Software Version, and software Release Date. 

13

Horn Volume 

“Volume equals X”

Customizes Horn Volume (16 levels). Max is 15. 

14

Bell Volume 

“Volume equals X”

Customizes Bell Volume (16 levels). Max is 15.

15

Motor Volume 

“Volume equals X”

Customizes Electric Traction Motor Volume. (16 levels). Max is 15.

16

Vents and Cooling Fan

Volume 

“Volume equals X”

Customizes Vents and Cooling Fans Volume (16 levels). Max is 15. 

17-19

Reserved

“Reserved”

20

Air Brakes Volume

“Volume equals X”

Customizes Air Brake Air Release Volume (16 levels). Max is 15. 

21-25

Reserved

“Reserved”

26

Pump Volume 

“Volume equals X”

Customizes Air Pump Volume (16 levels). Max is 15. 

27 

Air Let-off Volume

“Volume equals X”

Customizes Long Air Let-off Volume (16 levels). Max is 15. 

28

Short Air Let-off Volume

“Volume equals X”

Customizes Short Air Let-off Volume (16 levels). Max is 15. 

29

Reserved

“Reserved”

30

Squealing Brake/Flange

Volume 

“Volume equals X”

Customizes Squealing Brake/Flange Volume (16 levels). Max is 15. 

31

Reserved

“Volume equals X”

32

Coupler Volume 

“Volume equals X”

Customizes All Coupler Sound Volumes (16 levels). Max is 15. 

33

Reserved

“Reserved”

17

 Programming is even simpler using a Quantum Engineer Controller (see previous section on page 6).

18

 

POP

 is short for “

P

rogram 

Op

tion”. 

19

 The verbal programming responses (such as “Enter Programming” etc.) have a minimum volume setting to provide programming information even when the system volume is
turned all the way off. 

20

 You can set volume with the Manual Volume Control or with Programming or both. The Manual Volume Control will determine the range of volume control under Programming;
that is, if you turn the Manual Volume Control down to say, 50%, you will not be able to increase the volume above the 50% value using Programming.

21

 Some lights that are not controlled by the Quantum System may remain on. 

22

 Bell will not be heard on models without bell feature.

Electric Loco Q1 w/Volume Pot Operation Manual, Version 2.8

7/21

8 March 2006

Summary of Contents for Quantum 1 System

Page 1: ...Q1 w Volume Pot Operation Manual Version 2 8 1 21 8 March 2006 Electric Locomotive Operation Manual for QSI Quantum 1 System Analog DCC Sound Decoder Equipped locomotives with Potentiometer 8 March 20...

Page 2: ...is equipped with Ditch Lights they will automatically strobe from one light to the other when the Horn is being blown and will continue for five seconds after the horn signal has stopped3 Bell availab...

Page 3: ...locomotive respond almost immediately to throttle movements on your DC power pack it may be reprogrammed to use Standard Throttle Control STC Under STC there is no Inertial Control The Example at the...

Page 4: ...l12 if so equipped If you cannot enter Neutral or have difficulties with any of the operations you may need to program your locomotive for optimal use with your particular DC power pack see Analog Pro...

Page 5: ...rtia from rolling stock see Analog Programming Option 2 in next section The higher the Load setting the greater the inertia effect during acceleration and deceleration As you increase track voltage th...

Page 6: ...Technology QARC Technology uses special remote control signals to operate different Quantum System features without the need for complicated and expensive digital systems With QARC technology you can...

Page 7: ...Quick or Slow Operation Bell rings22 followed by a hoot to indicate locomotive returned to factory default 12 About Model number Each Quick or Slow Operation provides progressive information about Qua...

Page 8: ...ch26 Upon entering a Program Option you will hear the current setting for that option For unused Program Options you will hear Reserved For any volume option you will hear Volume equals X where X is i...

Page 9: ...on Or continue to V Max by moving the direction switch and waiting for the next Programming Option to be announced Note The final value of V Start may decrease from the original voltage reading becaus...

Page 10: ...Crash Coupler Fire Coupler Arm or Coupler Fire F4 Cooling Fans on or off Cooling Fans on or off F5 Dynamic Brake function on or off Dynamic Brake function on or off Disconnect only F6 Initiate Dopple...

Page 11: ...l you press F1 again43 There is no difference in operation between the bell button and its corresponding function key Note If your locomotive is equipped with Ditch Lights they will automatically stro...

Page 12: ...ol of certain automatic features by using their associated function key or keys Once you Take Control the features will no longer have automatic operation and you will control their operation and thei...

Page 13: ...er the last Shut Down stage it was at during power down and the locomotive will power up in the same stage If Start Up is initiated during any of the above Shut Down procedures Shut Down is aborted an...

Page 14: ...ute state is not maintained if power is turned off and then turned back on the locomotive will return to full volume setting Note Mute is shut off if the Status F10 key is pressed to allow clear audio...

Page 15: ...System Volume Enable Disable Horn Triggered Doppler Shift CV 51 2 Set CV 49 to 2 Set CV 51 to 0 to disable Horn Triggered Doppler set to 1 to enable Horn Triggered Doppler Changing Individual Sound V...

Page 16: ...value of CV 18 from the table Hear the new full Extended Address spoken out Set CV 29 bit 5 to 1 or set CV 29 to 38 62 to allow operation with your new Extended Address Disable Enable Verbal Announce...

Page 17: ...for the features indicated Extended Addressing Speed Tables Power Conversion 28 128 Speed Steps Reversal Direction Decimal Value Binary Value Hex Value X 2 00000010 2 X X 6 00000110 6 X X 18 00010010...

Page 18: ...ke sounds and the final distinctive squealing sounds as the Quantum equipped Electric locomotive slows to a stop Horn The Quantum System uses authentic locomotive sounds whenever possible All Quantum...

Page 19: ...d to operate on normal HO track voltage supplied by most HO power packs If track voltage exceeds 21 5 volts peak the motor drive circuit will automatically shut down and the locomotive will coast to a...

Page 20: ...motive with the F6 key71 Once started you can return to DC or DCC operation If the above methods do not start your locomotive use the reset jumper to reset your locomotive to factory default values as...

Page 21: ...ntum Quantum System Sound of Power Scale Sound Regulated Throttle Control QARC are trademarks of QSIndustries Inc MRC is a trademark of Model Rectifier Corporation All other trademarks are the propert...

Reviews: