2
Connections
The HF-63X1/X2 has barrier strip screw terminals that accept up to #10 AWG (5.3mm
2
) stranded loudspeaker wire.
INPUT Terminals
Connect the amplifier’s full range output signal to the HF-63X1 or HF-63X2
INPUT
terminals. Observe proper polarity; the amplifier’s
+
signal to
the HF-63X1 or HF-63X2
+ INPUT
, the amplifier’s
-
signal to the HF-63X1 or HF-63X2
-
INPUT
. Use the largest wire size and shortest wire
length for the application.
HF OUT Terminals
The
HF OUT
terminals are factory-connected to the compression driver. These terminals should
ONLY
be connected to the HF-63X1 or HF-63X2
compression driver. Observe proper polarity; the
+ HF OUT
signal to the compression driver’s
+
input, the
-
HF OUT
signal to the compression
driver’s
-
input.
LF OUT Terminals
The HF-63X1 is designed specifically for use with QSC’s LF-3115 low frequency loudspeaker and the HF-63X2 for the LF-3215 loudspeaker. The
LF OUT
terminals are factory-terminated to lead wires with spade-lugs. These should
ONLY
be connected to QSC’s model LF-3115 or model LF-
3215 low frequency loudspeaker. Observe proper polarity; connect the
+ LF OUT
signal to the low frequency loudspeaker’s
+
input, the
-
LF
OUT
signal to the low frequency loudspeaker’s
-
input.
HF-63X1 or HF63X2
Compression
Driver
Amplifier
HF OUT connection ter-
minals. Connect to HF-
63X1 or HF-63X2 com-
pression driver.
HF-63X1 or HF-63X2
INPUT connection
terminals
LF OUT connection
terminals. Connect to
LF-3115 or LF 3215
loudspeaker INPUT
terminals.
To LF-3115 or LF-3215
The HF-63X1 is designed
specifically for use with
QSC’s LF-3115 low fre-
quency loudspeaker and
the HF-63X2 for the LF-3215
loudspeaker.