46
Network Icon
•
Green:
The loudspeaker is connected to a functioning network.
•
Grey:
The loudspeaker has not been connected to a functioning network since its last power cycle.
•
Red:
The loudspeaker was previously connected to a functioning network since its last power cycle but has lost connection to that
network.
Ar-Q
™
(Array Equalization)
•
Blue:
Array equalization is engaged, and the current compensation is correct for the array deployment.
•
Orange:
Array equalization is engaged, but the current compensation is not correct for the array deployment.
•
Grey:
Array equalization has been defeated.
NOTE:
AC can only be defeated when loudspeaker/array is connected to QSC SysNav software app.
NOTE:
For QSC AWARE to function, the maximum number of LA108 or LA112 loudspeakers in any array is six (6).
Any arrays larger than 6 will require manual voicing setup (see Ar-Q
™
section).
High-Pass Filter
•
Blue:
The high-pass filter is engaged and matches all loudspeakers in the array.
NOTE:
Default is 80 Hz for use with L Class and KS Series subwoofer; however, a 100 Hz setting is available to be used
with legacy QSC KW181/KLA181 subwoofers.
•
Orange:
The high-pass filter is engaged, but it does not match the high-pass filter set in the rest of the array.
•
Grey:
High-pass filter has been defeated, and the loudspeaker is operating in its full-range state.
EQ
•
Blue:
The EQ is engaged, and it matches the EQ set in the rest of the array.
•
Orange:
The EQ is engaged, but it does not match the EQ set in the rest of the array.
•
Grey:
The EQ has been defeated.
NOTE:
EQ parameters can only be adjusted via QSC SysNav software app.
Menu
The menu can be accessed from the Home Screen by pressing the Menu button once, which will
provide access to the following parameters:
•
High-Pass Filter:
80 Hz or 100 Hz
•
Delay:
0 – 200 ms
•
EQ:
In or Bypassed (User EQ adjustment requires the QSC SysNav software app)
•
HF Shading:
-6 dB to +3 dB
•
Ar-Q
™
(Array Equalization):
Factory voicing optimization of the deployed array. These parameters
are set automatically when the array is
optimized
but can be defeated and set manually in the
event of a hardware failure of the infrared sensor.
◦
Box Count:
The number of loudspeakers in an array.
◦
Box Number:
The location of the loudspeaker in the array. In a 6-box array, 1 is the top, and 6 is the bottom.
◦
Total Splay:
The sum of the total splay angles between the array loudspeakers (do not count the Array Frame or
Sub-Stack angle).
— Figure 76 —