QSC DXP Series User Manual Download Page 9

9  

TD-000371-00-A

Specifi cations

Refer to the individual sections in this document for more information. Specifi cations are subject to change.

Parameter

Specifi cation

Parameter

Specifi cation

Dimensions (H/W/D):

1.75" x 19" x 15"

Audio Performance (DataPort Outputs)

Line voltage requirements

100 VAC – 240 VAC, 50/60 Hz

Dynamic range 
(unweighted):

>107 dB

Accessories included

6 ft. UL/CSA line cord, Connector Kit

THD+N at +12 dBu input 
level (per AES-17)

<.005 %

Front Panel Controls

Frequency response

20 Hz to 20 kHz

LCD page forward

Momentary switch

D/A conversion

24-bit delta-sigma, 48 kHz

Set parameter

Momentary switch

DSP Performance

Indicators

Filter topology

24-bit digital IIR

Power-on indicator

Green LED

Crossover fi lters

Linkwitz-Riley or Butterworth (6 - 48 dB/octave)

Status indicator

Tri-color LED (Red, Green, Amber)

Parametric EQ

Digital band-pass fi lter with ±20 dB of boost/
cut. Q is programmable in 1/10th octave steps 
from 1/20th to 4 octaves

Menu-driven LCD

2 line x 16 character LCD

CD Horn EQ

Digital shelf fi lter with up to ±10 dB of cut/boost 
programmable from 20 Hz to 20 kHz

Rear Panel Connectors

All pass fi lter

2nd  order  all  pass  fi lter  programmable  from                  
20 Hz – 20 kHz

Universal Mic/Line input

XLR — Mic (+ phantom power) or line level

Available sensitivity settings: 

-16 dBu, 10 dBu, 21 dBu, 27 dBu

Band polarity

Normal, inverted

DataPort outputs

HD-15 (x12) — QSC amplifi er interface

Band delay

Programmable in 21 µs steps from 0 ms to 
10 ms

Automation inputs

2-pin Euro-style (x2)

Amplifi er AC Control

All amps power on with DXP activation and can 
be placed into standby via user interface

Relay outputs

3-pin Euro-style (x4) – max 30 VDC

Automation Inputs

CobraNet

RJ45 (x2) 100 Mbps primary/backup network 
audio

Input Type

TTL Compatible or Dry Contact Closure

Audio Performance (Mic/Line Input)

Operating Mode

Connection to ground through a maximum 
impedance of 1 k Ohm for closure detect

A/D conversion

24-bit delta-sigma, 48 kHz

Relay outputs

Dynamic range 
(unweighted)

> 103 dB

Output type

Mechanical relay contacts

Input stage type

Active balanced

Compatible

Max 30 VDC output at 1 A. Can be wired as 
NO or NC

Input impedance

Balanced: 6.81 k Ohms

Unbalanced: 13.6 k Ohms

Audio network / Control connection to DCP

Max analog input level

-16

10

21

27

dBu

Protocol

CobraNet version 2 protocol

0.123

2.25

8.70

17.35

Vrms

CMRR typical (max)

20 Hz – 20 kHz >60 dB (>50 dB)

Data rate

100 Mbps (Fast Ethernet)

THD+N at 2 dB below clip 
(per AES-17)

<0.006%

Ports

1 Primary, 1 Backup (auto-failover)

Connection requirements

CAT-5 UTP cable or better (100 m maximum 
length), direct connection to wired network 
switch ports only, dedicated LAN or V-LAN

Summary of Contents for DXP Series

Page 1: ...DXP Series Digital Cinema Hardware User Manual DXP Digital Expansion Processor TD 000371 00 A TD 000371 00...

Page 2: ...ructed 3 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions could be created by an uneven distribution of weight 4 Connect the unit only to a properly rat...

Page 3: ...ftware or data contained on the serviced unit not originally included in the product Customers may have additional rights which vary from state to state or from country to country In the event that a...

Page 4: ...er supplies seamless recovery in the event of a failure Continued development of software and firmware will add new capabilities via easy updates Digital Signal Processing The DXP digital signal proce...

Page 5: ...rol connection b Green audio and control connections are both good c Amber either the audio or control connection is not working DXP Rear Panel Features 1 Analog audio input Mic Line 2 DataPort interf...

Page 6: ...ET to save and restart the DXP or Press Page to move cursor to N Press Set to exit edit mode without saving Press PAGE to move to next page 3 N A SN xxxxxxxxxx Serial Number FW 0 00 0000 Firmware Vers...

Page 7: ...nsure that these rear mounting points are securely fastened to rear rack rails or rack side walls Configuring the DXP DCP Manager is used to configure the DCP DXP system This includes configuring the...

Page 8: ...is connected to the NO contact and the NC contact is not connected DataPorts QSC DataPorts on the DXP rear panel are intended to interface to QSC amplifiers with v1 DataPorts These are the all capabl...

Page 9: ...ic phantom power or line level Available sensitivity settings 16 dBu 10 dBu 21 dBu 27 dBu Band polarity Normal inverted DataPort outputs HD 15 x12 QSC amplifier interface Band delay Programmable in 21...

Page 10: ...ce FAX 714 754 6173 World Wide Web www qsccinema com E mail info qscaudio com service qscaudio com 2012 QSC Audio Products LLC All rights reserved QSC the QSC logo QSControl net QSControl DCP Manager...

Reviews: