QSC DXP Series User Manual Download Page 8

8  

TD-000371-00-A

CobraNet Network

Connect one end of a data communications cable terminated with an RJ45 plug into the CobraNet

 Primary 

receptacle on the rear panel of the DXP product. Ensure that the lock tab on the cable engages with the RJ45 
receptacle on the rear  panel DXP connector. For systems requiring redundant network connections, connect a 
second data communications cable terminated with an RJ45 plug into the CobraNet

 Secondary receptacle on the 

rear panel of the DXP product. 

NOTE: 

 

Data communications cabling must be rated CAT-5 or better for all CobraNet

 connections.

Automation Inputs

The automation inputs use a 2-terminal Euro style (a.k.a. Phoenix) receptacle. The Automation Inputs can be connected to relay contacts or a switch 
and require a 2-terminal Euro style plug. The DXP rear panel label provides all necessary signal information. The negative terminal of each receptacle is 
at chassis potential.

Relay Outputs

Four relay outputs are provided via two 3-terminal Euro style (a.k.a. Phoenix) receptacles. Relay contacts are fl oating 
and rated for 30 VDC at 1A. Each output includes one common terminal, one normally open contact (NO), and one 
normally closed (NC) contact. These terminals are labeled C, NO and NC, respectively on the DXP rear panel. When 
the relay is not energized, the C terminal is connected to the NC contact and the NO contact is not connected. When 
the relay is energized, the C terminal is connected to the NO contact and the NC contact is not connected.

DataPorts

QSC DataPorts on the DXP rear panel are intended to interface to QSC amplifi ers with v1 DataPorts. These are the 
all-capable DataPorts, which are included on DCA and PL3 series amplifi ers. All DataPorts use the HD15 connector 
format and connect to QSC amplifi ers via data communications cables having male HD15 connectors on both 
ends. These are commonly referred to as VGA cables. To connect a DataPort cable between a DXP DataPort and an 
amplifi er DataPort, attach the cable’s male connectors to the HD15 ports and fi nger tighten the thumb screws on 
the connectors.

NOTE: 

 

Although many off-the-shelf VGA cables may work with satisfactory results, the QSC DataPort 

specifi cation requires that all conductors be present and that all audio I/O conductors be shielded. 
Therefore, only QSC supplied DataPort cables should be used. A variety of lengths are available 
through QSC’s Technical Services Group.

Mic/Line Input

A single Mic/Line Input is accessible on the DXP rear panel. This input can be used for mono non-sync sources or for 
connecting a microphone for local paging or announcements into the auditorium or to support various corporate or live 
events requiring a microphone. Phantom power may be enabled via DCP Manager™ confi guration or via the DXP front panel 
interface. The Mic/Line Input uses a standard 3-conductor XLR receptacle.

NOTE: 

 

The Mic/Line input uses standard XLR cables that are readily available through retailers specializing in 

musical equipment, pro audio or home electronics.

— Figure 4 —

 

— Figure 5 —

 

NC

NO

C

— Figure 6 —

 

— Figure 7 —

Summary of Contents for DXP Series

Page 1: ...DXP Series Digital Cinema Hardware User Manual DXP Digital Expansion Processor TD 000371 00 A TD 000371 00...

Page 2: ...ructed 3 When installing equipment into a rack distribute the units evenly Otherwise hazardous conditions could be created by an uneven distribution of weight 4 Connect the unit only to a properly rat...

Page 3: ...ftware or data contained on the serviced unit not originally included in the product Customers may have additional rights which vary from state to state or from country to country In the event that a...

Page 4: ...er supplies seamless recovery in the event of a failure Continued development of software and firmware will add new capabilities via easy updates Digital Signal Processing The DXP digital signal proce...

Page 5: ...rol connection b Green audio and control connections are both good c Amber either the audio or control connection is not working DXP Rear Panel Features 1 Analog audio input Mic Line 2 DataPort interf...

Page 6: ...ET to save and restart the DXP or Press Page to move cursor to N Press Set to exit edit mode without saving Press PAGE to move to next page 3 N A SN xxxxxxxxxx Serial Number FW 0 00 0000 Firmware Vers...

Page 7: ...nsure that these rear mounting points are securely fastened to rear rack rails or rack side walls Configuring the DXP DCP Manager is used to configure the DCP DXP system This includes configuring the...

Page 8: ...is connected to the NO contact and the NC contact is not connected DataPorts QSC DataPorts on the DXP rear panel are intended to interface to QSC amplifiers with v1 DataPorts These are the all capabl...

Page 9: ...ic phantom power or line level Available sensitivity settings 16 dBu 10 dBu 21 dBu 27 dBu Band polarity Normal inverted DataPort outputs HD 15 x12 QSC amplifier interface Band delay Programmable in 21...

Page 10: ...ce FAX 714 754 6173 World Wide Web www qsccinema com E mail info qscaudio com service qscaudio com 2012 QSC Audio Products LLC All rights reserved QSC the QSC logo QSControl net QSControl DCP Manager...

Reviews: