18
TD-001585-01-B
– 8-Channel
DPA 4K8Q / DPA 4K8Q
n
DPA 8K8Q / DPA 8K8Q
n
Configuration
Loads
Continuous Power
Continuous Power
4 or 8 Independent Channels
A, B, C, D, E, F, G, H
16 Ω
500
150
625
300
8 Ω
1000
300
1250
600
4 Ω
1000
300
1500
600
2 Ω
800
300
1000
300
2 Channels Combined
in Parallel
AB or CD or EF or GH
Doubles Current
8 Ω
1000
600
1250
1100
4 Ω
1250
600
2400
1200
2 Ω
1500
600
2500
600
3 Channel Combined in
Parallel ABC or EFG
Triples Current
8 Ω
1000
900
1250
1100
4 Ω
1500
900
2000
1800
2 Ω
1500
900
2500
1800
2 Channels Combined in
BTL Bridged
A+B or C+D or E+F or G+H
Doubles Voltage
8 Ω
1500
600
3000
1200
4 Ω
1400
400
1700
600
2 Ω
N/R
4 Channels Combined in
Bridged/Parallel
AB+CD, EF+GH
Doubles Current & Voltage
8 Ω
2500
1200
4000
2400
4 Ω
3000
1200
5000
2400
2 Ω
N/R
4 Channels Combined in
Parallel ABCD or EFGH
Quadruples Current
8 Ω
1000
1000
1200
1200
4 Ω
2000
1200
2400
2200
2 Ω
2500
1200
4000
2400
1 Ω
3000
1200
4000
2400
1 Specifications are subject to change without notice.
2 Max Power
»
Max Power data is based on the most potential any single amplifier channel can deliver. This data is most useful for asymmetrical loading
of amplifier channel and maximizing power utilization of the amplifier. When utilizing FlexAmp™ power requirements, be sure to take into
consideration the power capabilities of the channel AND the capabilities of the Power Supply.
»
Continuous Power indicates amplifier output capabilities with all channels driven with the same load without exceeding the capabilities of the power supply.
»
Power Spec is based on 1 kHz, 20 msec
3 N/R = Not Recommended