Attero Tech by QSC
Axiom Product Family
User Manual
QSC, LLC 2020
614-00063
–
Audio
Configuration
Based on the I/O mode selected the device can be configured with
two options.
Figure 28 - I/O configuration pots
–
Input Settings
The line-level input pads are adjusted using 2 rotary pots. A small
screwdriver is needed to adjust the input pad levels. The inputs
have an adjustable attenuation range of +24 to 0 dBu, allowing
an input full scale input signal range of 0 dBu to +24 dBu.
–
Output Settings
The output gains are adjusted using 2 rotary pots. A small
screwdriver is needed to adjust the gain levels. The outputs have
an adjustable gain range of 0 to +24dB, allowing for full scale
output levels of 0 dBu to +24 dBu.
–
3
rd
Party Control
The RS-232 port on the AXPio break-out box is intended for
connectivity to 3
rd
party control systems for extended integration
of Axiom into professional AV applications.
–
RS-232 Interface
The RS-232 interface on the AXPio is a pass through interface to
the Axiom port. Actual serial port settings can be found on select
Axiom products that support R2-232 control integration features.