Check the 16 voltage sensors in system.
CLI >
volt
Quantity of voltage sensors: 16
Voltage Sensor Value Status
-----------------------------------------------
Ctrl 1 Volt +3.3V 3.32V OK
Ctrl 1 Volt +12V 12.24V OK
Ctrl 1 Volt +5V standby 5.10V OK
Ctrl 1 Volt +3.3V standby 3.32V OK
Ctrl 1 Volt +1.8V 1.81V OK
Ctrl 1 Volt +0.9V 0.92V OK
Ctrl 2 Volt +3.3V 3.32V OK
Ctrl 2 Volt +12V 12.24V OK
Ctrl 2 Volt +5V standby 5.10V OK
Ctrl 2 Volt +3.3V standby 3.32V OK
Ctrl 2 Volt +1.8V 1.81V OK
Ctrl 2 Volt +0.9V 0.92V OK
Bac12V 12.00V OK
Bac5V 5.05V OK
Bac3.3V 3.30V OK
Bac3.3V standby 3.31V OK
Table 2-3
Voltage Description
Column Name
Description
Status
The status of the voltage:
OK: The voltage sensor is present and no error.
CRIT: The voltage sensor detected a critical error condition.
WARN: The voltage sensor detected a warning error condition.
FAIL: The voltage sensor is not accessible.
2.6.3.
Show PSU Information (psu)
Command
psu
Description
Show the information of power supply units in the system.
Syntax
psu