32 ©
Copyright 2017 QSAN Technology, Inc. All Right Reserved.
CLI >
temp
Quantity of temperature sensors: 11
Temperature Sensor Value Status HighCrit HighWarn LowWarn LowCrit
---------------------------------------------------------------------------
Ctrl 1 Backend Connector 30C OK 75 65 5 0
Ctrl 1 Location Bottom Right 42C OK 75 65 5 0
Ctrl 1 SAS Wide Port 1 29C OK 75 65 5 0
Ctrl 1 SAS Expander 65C OK 95 90 5 0
Ctrl 2 Backend Connector 30C OK 75 65 5 0
Ctrl 2 Location Bottom Right 41C OK 75 65 5 0
Ctrl 2 SAS Wide Port 1 29C OK 75 65 5 0
Ctrl 2 SAS Expander 65C OK 95 90 5 0
Backplane Location Left 30C OK 70 65 5 0
Backplane Location Middle 34C OK 70 65 5 0
Backplane Location Right 29C OK 70 65 5 0
Table 2-2
Temperature Sensor Description
Column Name
Description
Status
The status of the temperature sensors:
OK: The thermal sensor is present and no error.
CRIT: The thermal sensor detected a critical error condition.
WARN: The thermal sensor detected a warning error condition.
FAIL: The thermal sensor is not accessible.
2.6.2.
Show Voltage Information (volt)
Command
volt
Description
Show the voltage sensors information of the system.
Syntax
volt
Parameters
none
Example
Summary of Contents for XCube DASXD5324S
Page 12: ......
Page 15: ...Getting Started with CLI 3 ...