background image

STEP 

1

 IQ MINI DW EXTENDED S LINE QUICK INSTALL GUIDE

Exterior Doors

Sliding glass doors

Windows

CHOOSE 
INSTALLATION 
LOCATION

Also great for: 

Medicine cabinets 
Gun safes 

Garage doors 
Interior doors

Sensor: 2.5”H x 1”W x .5”D  

Wireless signal range: 600ft (200M), open air.  
Code outputs: tamper, tamper restore, alarm (primary open), alarm restore 
(primary close), external alarm (secondary wired open), external restore 
(secondary wired closed), low battery. 
Transmitter frequency: 319.5 MHz  
Unique code ID 
Supervisory keep-alive interval: 70 minutes.  
RF Peak field strength: typical 36000 uV/m at 3m 

Operating Temperature: -10C~50C 
Relative Humidity: 5-95% Non-Condensing  
Storage Temperature: -40-80C   

Replace battery with exact replacement every 5 years with 3V CR2032 
Lithium (x2).

SPECIFICATIONS

SEE REVERSE FOR REMAINING STEPS

USING EXTERNAL TERMINALS

Connect wired devices such as 
garage door contacts, door window 
contacts, and panic switches using 
the external terminals. Wire lead 
length should not exceed 20’.

Safes

Cabinets

This is a quick guide for experienced installers only.  Refer to http://dealers.qolsys.com (login required) 