INSTALLATION MANUAL

STEP 1: INSTALL THE HARDWARE

Close, then Open the Door to 

the enclosure on the IQ 
Hardwire 16-F.  This will 

“tamper” the module and send a 

learn in signal to the IQ Panel 2 

STEP 2: PAIR THE IQ HARDWIRE 16 - F WITH THE IQ PANEL 2

Note:  This step is required and allows the IQ Panel 2 to control the wireless Siren Relay, reset the two-wire smoke detectors after a fire event and supervise the battery, 
AC power status, aux power out & tamper.  The IQ Panel 2 must have the Tx/Rx 319.5 MHz SRF card installed with RF PIC 11.1.4 G2 or higher.

Press and hold “EOL LEARN” 

for 1-2 secs.  

(all Zone LED’s 

flash and then turn off)

EOL CAL LED will turn ON.  

This indicates the module is 

now in “Auto Learn” mode

Follow the onscreen 

prompts on the IQ Panel 

to finish the enrolling 

process.  The IQ Hardwire 

16-F should be learned in 

as a “Hardwire Translator”

Place your IQ Panel 2 in “Auto 

Learn” mode: 

Settings/Advanced Settings/

Installation/Devices/Security 

Sensors/Auto Learn Sensor

Page    of 4 Qolsys Confidential and Proprietary.

2

1. Mount the IQ Hardwire 16-F enclosure vertically in your desired location 
2. Install the provided antenna through the hole in the top of the enclosure and into the “ANT” terminal at the top of the 

unit, keeping it free from obstructions 

3. Wire all hardwired sensors into the terminals marked Zone 1-15.  Zone 16 is reserved for two-wire smoke detectors: 

a. All zones must have either a 4.7k resistor (included) or a 1k - 10k resistor installed, depending on the 

which Resistor Mode is selected (see Troubleshooting on page 3), in either the N/O (parallel) or N/C 
(series) position. 

b. Wire the positive and negative leads from powered devices, such as motion sensors and glass break 

detectors, into the “AUX” (+) and “GND” (-) terminals to power the devices. 

c. The case tamper should be pre-wired from the factory and does not require a resistor.   If the case 

tamper is not being used, permanently shunt the zone with a piece of wire. 

d. Optional:  Wire the hardwired siren (60VDC/1A Max, see wiring diagram). 

4. Plug  in  a  5Ah  lead  acid  backup  battery  with  included  battery  leads  (battery  not  included)  and  secure  in  place  with  the 

appropriate battery strap. 

5. Using the provided 16vDC power supply, connect the leads to the terminals marked “+16.0V” & “GND”, then plug then 

supply into a wall outlet.  

NOTE: dashed wire is positive. 

RESISTOR MODES: 

 

Change between two distinct resistor modes.  The default mode is “UL Mode” where 4.7k resistors are required on each zone.  In 

this mode the Processor LED blinks rapidly (8 times per second).   
If UL installation is not required, “EOL Resistor Learning” can be enabled.  In this mode the Processor LED blinks slowly (1 time per second) and any resistor 
value from 1k to 10k can be used.   

NOTE:  Zone 16 is dedicated for 2-wire smokes and requires a 4.7k resistor regardless of Resistor Mode.

 

To change modes, power down the unit (battery & AC), hold down “EOL LEARN” for 8 seconds while re-applying power to the device.  Processor, RF Xmit 
and EOL CAL LED’s will begin to flash rapidly indicating that the mode has been changed.

Summary of Contents for IQ Hardwire 16-F

Page 1: ...put Voltage 16 0VDC Plug In Transformer Backup Battery 12VDC 5AH Max not included Dimensions 16 X 14 X 3 Operating Temperature 32 to 122F 0 to 50C EOL Supervision 4 7k Ohm fixed or 1k 10k Ohm depending on Resistor Mode Input Zones 15 N O or N C Smoke Zone 1 two wire smoke loop 10 detectors max Support for System Sensor 2W B 2WT B 2WTA B Detector models should not be mixed Auxiliary Voltage Output ...

Page 2: ... resistor included or a 1k 10k resistor installed depending on the which Resistor Mode is selected see Troubleshooting on page 3 in either the N O parallel or N C series position b Wire the positive and negative leads from powered devices such as motion sensors and glass break detectors into the AUX and GND terminals to power the devices c The case tamper should be pre wired from the factory and d...

Page 3: ... default mode is UL Mode where 4 7k resistors are required on each zone In this mode the Processor LED blinks rapidly 8 times per second If UL installation is not required EOL Resistor Learning can be enabled In this mode the Processor LED blinks slowly 1 time per second and any resistor value from 1k to 10k can be used NOTE Zone 16 is dedicated for 2 wire smokes and requires a 4 7k resistor regar...

Page 4: ...te the equipment This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS s Son fonctionneme...

Reviews: