background image

Page    of 4 Qolsys Confidential and Proprietary.

4

WIRING DIAGRAM

ALT SIREN WIRING - A

ALT SIREN WIRING - B

Optional

 Siren Relay wiring using GND (-) 

and IQ Panel 2 “EXT Siren” output*

Optional

 Siren Relay wiring using 12v (+) 

and IQ Panel (GEN1) “Buzzer” output*

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not 

cause harmful interference, and (2) this device must accept any interference received, including interference that may cause 

undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the 

user's authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two 

conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including 

interference that may cause undesired operation of the device.

Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux 

deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute 

interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.

FCC ID: 2ABBZ-RF-CHW-FIRE

IC: 11817A-RFCHWFIRE

*

Not intended for UL Installations

*

Not intended for UL Installations

INSTALLATION MANUAL

For Service Contact 
COMPANY NAME: 
ADDRESS: 
PHONE:

UL 1023, UL985, ULC 1023  

& ULC S545 LISTED

Summary of Contents for IQ Hardwire 16-F

Page 1: ...put Voltage 16 0VDC Plug In Transformer Backup Battery 12VDC 5AH Max not included Dimensions 16 X 14 X 3 Operating Temperature 32 to 122F 0 to 50C EOL Supervision 4 7k Ohm fixed or 1k 10k Ohm depending on Resistor Mode Input Zones 15 N O or N C Smoke Zone 1 two wire smoke loop 10 detectors max Support for System Sensor 2W B 2WT B 2WTA B Detector models should not be mixed Auxiliary Voltage Output ...

Page 2: ... resistor included or a 1k 10k resistor installed depending on the which Resistor Mode is selected see Troubleshooting on page 3 in either the N O parallel or N C series position b Wire the positive and negative leads from powered devices such as motion sensors and glass break detectors into the AUX and GND terminals to power the devices c The case tamper should be pre wired from the factory and d...

Page 3: ... default mode is UL Mode where 4 7k resistors are required on each zone In this mode the Processor LED blinks rapidly 8 times per second If UL installation is not required EOL Resistor Learning can be enabled In this mode the Processor LED blinks slowly 1 time per second and any resistor value from 1k to 10k can be used NOTE Zone 16 is dedicated for 2 wire smokes and requires a 4 7k resistor regar...

Page 4: ...te the equipment This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS s Son fonctionneme...