WIRING DIAGRAM
ALT SIREN WIRING - A
ALT SIREN WIRING - B
Optional
Siren Relay wiring using GND (-)
and IQ Panel 2 “EXT Siren” output*
Optional
Siren Relay wiring using 12v (+)
and IQ Panel (GEN1) “Buzzer” output*
*
Not intended for UL Installations
*
Not intended for UL Installations
For Service Contact
COMPANY NAME:
ADDRESS:
PHONE:
#
ZONE LIST
#
ZONE LIST
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
2W
SMK
Document #: IQHW16FDL
Revision Date: 5/21/19
Qolsys Part #: QS7134-840
The
IQ Hardwire 16-F
offers a cost effective way of integrating hardwired security &
smoke detector zones with the IQ Panel 2. It includes a large enclosure with ample
wire routing room, backup battery charging, 500mA of 12volt auxiliary power, an
onboard siren relay, built-in status LED’s for each zone and support for up to 10
two-wire smoke detectors. Normally Open and Normally Closed contacts are
supported as well as powered zones like motion sensors and glass break detectors.
Note: Not for use with CO detectors
INSTALLATION MANUAL
TECHNICAL SPECIFICATIONS
Document #: IQHW16FEQG
Revision Date: 10/7/19
Qolsys Part #: QS7134-840
ENCLOSURE OVERVIEW
Confidential &
Proprietary.
Made in Taiwan.
Page of 4 Qolsys Confidential and Proprietary.
1
Input Voltage:
16.0VDC Plug-In Transformer
Backup Battery:
12VDC 5AH Max (not included)
Dimensions:
16” X 14” X 3”
Operating Temperature:
32 to 122F (0 to 50C)
EOL Supervision:
4.7k Ohm fixed
or
1k-10k Ohm
depending on Resistor Mode
Input Zones:
15 N/O or N/C
Smoke Zone:
1 two-wire smoke loop, 10 detectors
max. Support for System Sensor® 2W-B, 2WT-B,
2WTA-B*
*Detector models should not be mixed
Auxiliary Voltage Output:
12VDC @ 500mA Max
Tamper Zone:
Used for case tamper, no resistor
Relay Contact:
60VDC/1A Max drives siren
Compatible Control Panel:
The IQ Hardwire 16-F
is for use with the Qolsys IQ Panel 2 only. Refer to
the full IQ Panel 2 installation manual for typical
installation layout, including recommended
locations of the control unit, detectors and
notification appliances.
Enclosure:
For UL Installations, Qolsys enclosure
QR0073-840 shall be used.
Listed Resistor:
For UL Installations, Qolsys 4.7K
Fire Resistor Part # QR0072-840 shall be used on
the 2-wire fire loop at the end of line.
Wiring:
For UL Installations, recognized limited
energy cable shall be used.
UL REQUIREMENTS
INFORMATION
Tamper
Expansion
Slot
Battery Compartment
(5aH & 8aH compatible)
Locking
Screw
Optional
Cam Lock
Door
Label
Zip Tie
Rails
Knock
Outs
Expansion Battery
Compartment
ACCESSORIES
Resistors (x16)
5aH Battery
Bracket (x2)
8aH Battery
Bracket (x2)
Knock Out
Bushings (x2)
Power Supply Battery Cables
RF Antenna (x1)