Qmark DBA Installation, Operation & Maintenance Instructions Manual Download Page 6

12/10

Part No. 5200-2052-005

ECR 38668

LIMITED WARRANTY

All  products  manufactured  by  Marley  Engineered  Products  are  warranted  against  defects  in  workmanship  and  materials  for  one  year  from  date  of  installation,  except 
heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from
accident,  misuse,  or  alteration;  nor  where  the  connected  voltage  is  more  than  5%  above  the  nameplate  voltage;  nor  to  equipment  improperly  installed  or  wired  or 
maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products
to Marley Engineered Products Service Center. Within the limitations  of this warranty, inoperative units should be returned to the nearest Marley authorized service cen-
ter or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that
such repair or replacement is the exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM
THIS  AGREEMENT.  MARLEY  ENGINEERED  PRODUCTS SHALL  NOT  BE  LIABLE  FOR  CONSEQUENTIAL  DAMAGES  ARISING  WITH  RESPECT  TO  THE 
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the fac-
tory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization,
include all catalog numbers shown on the products.

HOW TO OBTAIN WARRANTY SERVICE AND 
WARRANTY PARTS PLUS GENERAL INFORMATION

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

Note: When obtaining service always have the following:

1. Model number of the product
2. Date of manufacture
3. Part number or description

470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA

No. 10 Wires

Factory Wiring

Field Wiring

Element

Element

Ground Screw

Ground Screws

Thermal Protector

Thermal Protector

Power Supply to Circuit Breaker

To other
heater

To other
heater

No. 10 Wires

Fig. 7

Typical Wiring of Multiple Heaters (without controls)

Summary of Contents for DBA

Page 1: ...exhaust in any manner 5 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 6 Serious injury or death co...

Page 2: ...8188 188 1504 7 2 6 3 5 4 4 3 2 5 08250 250 2000 9 6 8 3 7 2 5 8 3 3 09100 100 900 4 3 3 8 3 2 2 6 1 5 09125 9 125 1125 5 4 4 7 4 1 3 2 1 9 09150 2743mm 150 1350 6 5 5 6 4 9 3 9 2 3 09188 188 1692 8 1...

Page 3: ...SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Serious injury or death could result from electric shock Make sure electrical power supply circuit coming to heater are disconnected at main disconn...

Page 4: ...E If a heater has a disconnect switch and or thermostat and is to have a filler section at the left end the filler must not cover the access to those controls 4 If the run of the heaters includes an i...

Page 5: ...sure it has adequate clearances and the free airflow around heater is not restricted If heater continues to cycle on this safety control discontinue using until it can be inspected and or repaired by...

Page 6: ...BILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CO...

Page 7: ...rico o incendio o de da os al calefactor 6 Un choque el ctrico podr a producir lesiones graves o la muerte Aseg rese de que el circuito de alimentaci n el ctrica del calefactor est desconectado en el...

Page 8: ...4125 4 125 500 4 2 2 4 2 1 1 8 1 4 04150 1219 mm 150 600 5 0 2 9 2 5 2 2 1 7 04188 188 752 6 3 3 6 3 1 2 7 2 2 1 3 04250 250 1000 8 3 4 8 4 2 3 6 2 9 1 7 05100 100 500 4 2 2 4 2 1 1 8 1 4 0 8 05125 5...

Page 9: ...o podr a producir lesiones graves o la muerte Aseg rese de que el circuito de alimentaci n el ctrica del calefac tor est desconectado en el tablero de servicio o desconectador principal antes de insta...

Page 10: ...ecci n de relleno en el extremo izquierdo sta no debe cubrir el acceso a esos controles 4 Si el tramo de los calefactores incluye una esquina interior o una esquina exterior monte la esquina contra la...

Page 11: ...de aire alrededor del calefactor no se encuentre restringida Si el calefactor contin a haciendo ciclos con este control de seguridad interrumpa su uso hasta que lo pueda inspeccionar y o reparar un el...

Page 12: ...ODUCTS NO SE HAR RESPONSABLE POR DA OS CONSIGUIENTES QUE SE PRODUZCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos estados o jurisdicciones...

Page 13: ...tincelles lectriques Ne l utilisez pas dans des zones o de l essence ou des liq uides inflammables sont utilis s 3 Ce radiateur est chaud quand il est en fonctionnement Pour viter des br lures ne lai...

Page 14: ...Total en 208 V 240 V 277 V 347 V 600 V catalogue L par pied watts 1 Ph 3 Ph 1 Ph 3 Ph 1 Ph 1 Ph 1 Ph 3 Ph 02375 375 750 3 6 3 1 2 7 02500 28 500 1000 4 8 4 2 3 6 2 9 02600 711 mm 600 1200 5 8 3 3 5 0...

Page 15: ...ESSURES AUX PERSONNES OBSERVEZ LES CONSIGNES SUIVANTES 1 Une blessure s rieuse voire mortelle peut r sulter d une commo tion lectrique Assurez vous que le circuit du secteur d alimenta tion lectrique...

Page 16: ...mit de gauche cette section ne doit pas couvrir l acc s ces commandes 4 Si l ensemble des radiateurs comprend un angle rentrant ou saillant montez d abord cet angle sur la cloison voyez les instructi...

Page 17: ...s par le dispositif de s curit cessez de l utiliser avant qu il ait t inspect et ou r par par un lectricien qualifi INSTRUCTIONS D ENTRETIEN Votre radiateur vous fournira des ann es de bon service et...

Page 18: ...s frais de main d uvre et les frais de port encourus pour retourner le produit au centre de r paration de la soci t Marley Engineered Products Sous r serve des restrictions figurant dans cette garanti...

Reviews: