4. Run power supply cable through the connector, leaving about 8” of

wire inside the box.

5. Connect the supply cable ground wire to green ground screw provided.

NOTE

: Lead holes for a #8 sheet metal screw have been provided in the

sides of the back box.. After the finished wall or ceiling has been put up,

drive a # 8(m4) sheet metal screw (recommended 1” long) through the

side of the box not mounted to the stud. This will prevent the back box

from pulling out when installing the heater assembly. (See Figure 1)

INSTALLATION OF BACK BOX

IN EXISTING CONSTRUCTION

(WALL OR CEILING)

1. Carefully mark and cut a hole measuring 9-3/8" (235mm) wide by 11-

1/8" (283mm) long. One edge of the hole must be cut along the

edge of a stud.

2. Proceed to No. 1 through 5 (Installation of Wall Box in New

Construction).

FIELD CONVERSION FOR LOWER WATTAGE RATING

NOTE

: Refer to specification chart for lower wattage ratings which are

available.

To convert heater to lower wattage rating, completely remove red jumper

wire from both heating elements (See Figure 2). Discard this jumper. Be

sure remaining wires are securely connected.

INSTALLATION AND WIRING

OF HEATER / FAN ASSEMBLY

1. Following wiring diagram (Figure 3) connect supply wiring to heater

leadwires in back box.

NOTE:

For 120 and 277 volt heaters connect the white neutral supply

lead to the heaters white pigtail lead, and connect the black supply lead

to the heater black pigtail lead. For 208 and 240 volt heaters change the

color of the heaters white pigtail lead to black by wrapping with black elec-

trical tape. (Most electrical codes require the supply leads to be con-

nected to black leads). Then connect the two black supply leads to the

two black receptacle leads.

GENERAL

The heater is designed for recessed installation in 2” X 4” (50mm X

101mm) stud or larger wall or ceiling sections using the wall box provid-

ed. The heater may also be surface mounted by using the Surface

Mounting Frame, Model CWHSM or semi-recess mounted by using a

CWHS1 (for 1” (25 mm) recess frame) or a CWHS2 (for 2” (50mm) recess

frame). All three accessories are ordered separately. The heater may be

wired with standard building wire (60°C). Refer to specification chart (see

pg. 4) for correct supply voltage and wire size.

NOTE:

The optimum mounting height for this heater is 18" to 24" (450 to

600mm) from floor to bottom of back box.

Do not

install closer than

4”(101mm) from the floor.

For surface or semi-recess mounting, consult Installation Instructions

packed with CWHSM, CWHS1, CWHS2.

INSTALLATION OF WALL BOX

IN NEW CONSTRUCTION

(WALL OR CEILING)

NOTE

: If the finished wall surface is already up, follow instructions for

“INSTALLATION OF BACK BOX IN EXISTING CONSTRUCTION”.

1. Determine which side of the back box is to be mounted against a

stud and bend the tabs at the rear corners out 90 degrees so that

the back box will be square with the stud after installation. (See

Figure 1).

2. Remove one of the knockouts on socket side of the back box and

install a cable or conduit connector.

3. Position back box against side of studs and secure using nails or screws

as shown in Figure 1.

NOTE: The back box must be installed with the front edge flush with

the finished surface.

Figure 2

THE HEATER IS HOT WHEN IN USE.

DO NOT

INSTALL THE

HEATER BEHIND DOOR, BEHIND TOWEL RACK, IN CLOSET,

WHERE CURTAINS OR DRAPES COULD TOUCH OR BECOME

SCORCHED BY HEATER, OR WHERE AIRFLOW TO HEATER MAY

BE OBSTRUCTED. KEEP ELECTRICAL CORDS, BEDDING, FURNI-

TURE AND OTHER COMBUSTIBLES AWAY FROM HEATER.

TO PROVIDE FOR SAFE OPERATION, THE FOLLOWING CLEAR-

ANCES MUST BE MAINTAINED.

WALL MOUNTING:

• MINIMUM FOUR (4) INCHES (102MM) TO

FLOUR • MINIMUM TWELVE (12) INCCHES (305MM) TO ADJA-

CENTT WALLS • MINIMUM THIRTY SIX (36) INCHES (915MM) TO

CEILING

CEILING MOUNTING:

• MINIMUM TWELVE (12) INCHES (305MM TO

ANY WALL

TO PREVENT HAZARD OF FIRE OR ELECTRICAL SHOCK,

DO NOT

INSTALL WITHOUT BACK BOX.

CAUTION

IMPORTANT

WARNING

CAUTION

2

Figure 1

Remove red

jumper for

lower wattage

rating

!

!

!

!

AN ELECTRICAL SHOCK, FIRE OR WATER DAMAGE COULD

RESULT IF WIRING OR PIPING IS DAMAGED DURING CUTTING.

MAKE SURE ALL WIRING AND PIPING ARE CLEAR OF AREA

BEFORE CUTTING.

CAUTION

!

BEND

OUT

TAB

CABLE CLAMP

BACK BOX

LEAD

HOLES

SUPPLY

WIRING

CABLE

NAILS OR

SCREWS (2)

DO NOT USE A REMOTE THERMOSTAT WITH THIS HEATER.

BUILT IN THERMOSTAT CYCLES THE HEATING ELEMENT ONLY.

FAN DELAY CONTROL AUTOMATICALLY TURNS FAN ON AND

OFF, AND PROVIDES A FAN DELAY OFF FEATURE TO REMOVE

RESIDUAL HEAT AFTER THERMOSTAT HAS TURNED HEATING

ELEMENTS OFF. WIRING OF HEATER IN ANY MANNER WHICH

DEFEATS THE FAN DELAY OFF FEATURE CAN RESULT IN

OVERHEATING AND PERMANENT DAMAGE TO HEATER, AND

WILL VOID THE WARRANTY.