C–Flash Update
QLogic Adapter Flash Update — Windows Server
C-6
NE0154601-00 A
Here is an example of the Windows Server
nxflash --all
output for local
area connection 8:
C:\netxen\4.0.223\utils>nxflash -i "Local Area Connection 8"
--all
NETXEN Port is Port 0
Verifying flash...Done.
0/9 - Init
*** Currently in flash ***
Board Type
: Quad Gig LP
Firmware Version : 4.0.222
MAC Address 0
: 00:0E:1E:00:7F:24
MAC Address 1
: 00:0E:1E:00:7F:25
MAC Address 2
: 00:0E:1E:00:7F:26
MAC Address 3
: 00:0E:1E:00:7F:27
Serial Number
: QG88BK0130
NIC binary romimage found in C:\netxen\4.0.223\utils
Rom Image :
C:\netxen\4.0.223\utils\lp_qg_cut_thru_b1_romimage
1/9 - Extracting Romimage
Firmware version From Board: 4.0.222
Firmware version From Romimage: 4.0.223
WARNING: This operation will take the NIC off line.
Do you wish to upgrade? (Y/N) y
5.
Reboot the system.
6.
Type the following command to verify that the Flash has been updated (
n
is
the number of the port being flashed):
nxflash.exe -i “Local Area Connection
n
” --info
(the quotation
marks are required)