STEP 16
15
STEP 18
17
STEP 26
24
STEP 27
25
STEP 3
22
STEP 23
21
STEP 17
5/16"
16
STEP 19
18
STEP 20
STEP 20
19
STEP 21
20
STEP 25
23
15. Raise the wick to its highest position and tighten the
wing nuts in several steps.
16. Check the wick height. It should be 5/16 above the collar.
17. Check for the correct clearance between wick holder
and draft tube. It should be the same all around.
18a. Reinstall the tip-over switch assembly by pushing the
extinguish knob.
18b. Connect the 3 connectors (3EA) with the circuit board.
18c. Remove the connector (1EA) from the ignitor.
19. Check the function of the tip-over safety stop by push-
ing the extinguish button to upset the pendulum.
20. Reinstall the automatic ignition assembly.
21. Reinstall the wind cover A / B.
22. Reinstall the cabinet.
23. Tighten the 5 screws on the cabinet and reinstall the
sensor at the back of the cabinet.
24. Reinstall the combustion chamber and the fuel tank.
25. Reinstall the wick adjusting knob. Close the front plate.
Install the batteries in the battery case and fill the fuel
tank with Qlima Premium Quality Fuels. Set the tank
into the heater and wait at least 60 minutes for the
new wick to fully saturate with the fuel.