of fire or explosion due to ignition of the
refrigerant caused by electric heaters, stoves,
or other sources of ignition.
• The appliance must be stored in such a way as
to prevent mechanical failure.
• Individuals who operate or work on the
refrigerant circuit must have the appropriate
certification issued by an accredited organi-
zation that ensures competence in handling
refrigerants according to a specific evaluation
recognized by associations in the industry.
• Repairs must be performed based on the rec-
ommendation from the manufacturing com-
pany.
Maintenance and repairs that require the assis-
tance of other qualified personnel must be per-
formed under the supervision of an individual
specified in the use of flammable refrigerants.
Appliances shall be installed,operated and stored
in a room with a floor area larger than 4 m
2
. The
appliance shall be stored in a well-ventilated area
where the room size corresponds to the room area
as specified for operation.
INSTRUCTIONS FOR REPAIRING APPLIANCES CONTAINING R290
1 GENERAL INSTRUCTIONS
This instruction manual is intended for use by individuals possessing adequate
backgrounds of electrical, electronic, refrigerant and mechanical experience.
1.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimised. For repair to
the refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
1.2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of
a flammable gas or vapour being present while the work is being performed.
1.3 General work area
All maintenance staff and others working in the local area shall be instructed on the
nature of work being carried out. Work in confined spaces shall be avoided. The area
around the workspace shall be sectioned off. Ensure that the conditions within the
area have been made safe by control of flammable material.
1.4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially flammable
4
44
man_P652 ('21) V3.indd 44
man_P652 ('21) V3.indd 44
16-12-2021 16:39
16-12-2021 16:39
Summary of Contents for P 652
Page 55: ...4 55 man_P652 21 V3 indd 55 man_P652 21 V3 indd 55 16 12 2021 16 43 16 12 2021 16 43 ...
Page 73: ...u 73 man_P652 21 V3 indd 73 man_P652 21 V3 indd 73 16 12 2021 16 46 16 12 2021 16 46 ...
Page 110: ...man_P652 21 V3 indd 110 man_P652 21 V3 indd 110 16 12 2021 16 54 16 12 2021 16 54 ...
Page 111: ...man_P652 21 V3 indd 111 man_P652 21 V3 indd 111 16 12 2021 16 54 16 12 2021 16 54 ...