94
THE CONTROL PANEL
• Lowest ambient working condition: 5°C / 40% relative humidity
• Highest ambient working condition: 35°C / 90% relative humidity
Dehumidify
Dry clothes Timer
5
Tank full
6
Defrost Filter cleaning
A
ON/OFF
2
Mode
Digital display
3
Humidity
4
Timer
NOTE!
• Water bucket must be correctly installed for the dehumidifier to operate.
• Do not remove the bucket while unit is in operation.
• If you want to use drain hose to drain water away, please install the hose
according to section "Drainage method".
• Each time pressing the effective button on the control panel will give out a
"beep" sound.
• When tuning on the unit, the running indicator is ON. Running indicator is
OFF under standby status.
G
OPERATION
A
ON/OFF: Press the on/off button
to turn on and off the unit. When turning
on the unit for the first time, it dehumidifies continuously. The compressor is turned
on and the fan motor runs at low speed. At the same time, the dehumidify sign
lights up, and the digital display
shows the ambient humidity. (When
the ambient humidity value is less than 30%, it shows LO, when humidity value is
greater than 90%, it shows HI.)
2
Mode: Press the mode button
to set the unit in dehumidify mode
or dry
clothes mode
. The selected sign will light up.
3
Humidity: The requested ambient humidity can be set by touching the humidity
button
. (The values can be set to CO~40%~50%~60%.) In dehumidify mode,
when pressing the humidity button
for the first time, the digital display
shows the selected humidity value; When pressing it for the second time, it’s
changing the setting of humidity value.
When the requested ambient humidity e.g. is set to 50% and the unit detects that
the current ambient humidity is higher than 52%RH, the unit starts; when the unit
detects that the current ambient humidity is less than 48%RH, the units stops. For
continuous dehumidifying use the CO setting.
When pressing the humidity button
for five seconds, the digital display
shows the ambient temperature. After five seconds the digital display
returns
to show the ambient humidity.
4
Timer: By pressing the timer button
the unit is set to run for ~1h~2h~4h···
or 9h. When the timer function is in use the timer sign