2
Model number
SESA-TI
SESAL-TI
SESALR-TI
SESAS-TI
Range of
operating voltage
DC 24V
AC 120V or 230V
Ex mark
IECEX - Ex db IIC T6 Gb
ATEX - II2G Ex db IIC T6 Gb
Ambient operating
temperature
–40°C ≤ Ta ≤ 60°C
Explosion proof
Zone
Zone1, Zone2
Protection rating
IP66
Model
number
Voltage
Power
consumption Current
Bulb specifications
Sound pattern and volume
Certificate
Weight
Color
Volts/
Watts
Configuration
Part#
SESA-TI
DC24V
46W
1.640A 24V15W
G23 15S
18
• WS-5 Warning sounds
: Max.118dB
• WP-Special warning sounds
: Max.118dB
• WM-5 Melodies : Max.118dB
• WA-5 Alarms: Max.116dB
• WV-5 Customizable sounds
: 110-115dB
8.57kg
R-Red
A-Amber
G-Green
B-Blue
AC120V
0.320A 12V15W
G23 15S
17
9.27kg
AC230V
0.200A 12V15W
G23 15S
17
9.27kg
SESAS-TI
DC24V
46W
1.300A
200V
-550V
EUB0641
-1A(G)
Utype
48
8.45kg
AC120V
0.320A
8.86kg
AC230V
0.200A
8.86kg
Model
number
Voltage
Power
consumption
Current
Sound pattern and volume
Certificate
Weight
Color
SESAL-TI
DC24V
39.1W
1.130A
• WS-5 Warning sounds
: Max.118dB
• WP-Special warning sounds
: Max.118dB
• WM-5 Melodies : Max.118dB
• WA-5 Alarms: Max.116dB
• WV-5 Customizable sounds
: 110-115dB
8.42kg
R-Red
A-Amber
G-Green
B-Blue
AC120V
0.270A
9.02kg
AC230V
0.170A
9.02kg
SESALR-TI
DC24V
41.4W
1.190A
8.31kg
AC120V
0.300A
7.92kg
AC230V
0.180A
7.92kg
SESAS
-
WS
-
230
-
R
-
TI
[Model number]
[Sound]
[Voltage]
[Color]
[Telephone Initiated]
|
|
|
|
|
• SESA
• SESAL
• SESALR
• SESAS
• WS-Warning sounds
• WP-Special warning sounds
• WM-Melodies
• WA-Alarms
• WV-Customizable sounds
• 24-DC24V
• 120-AC120V
• 230-AC230V
R-Red
A-Amber
G-Green
B-Blue
TI-
Telephone Initiated
Ordering Specifications
■
General Product Specification
Product Specifications
Zone
definitions(Gas)
Zone 1
High risk gas/vapour
Zone 2
Medium risk gas/vapour
Group
definitions(Gas)
GROUP
II A
Acetone, Petrol, Methanol, Propane, Toluene
GROUP
II B
Ethylene, City gas
GROUP
II C
Hydrogen, Acetylene, Carbon sulphide
Maximum
surface
temperature
of electrical
equipment
T1
450°C
T2
300°C
T3
200°C
T4
135°C
T5
100°C
T6
85°C
Zone
definitions(Dust)
Zone 21
High risk powder/dust
Zone 22
Medium risk powder/dust
Group
definitions(Dust)
GROUP
II A
Ignitible fibers/flyings(mzore than 0.5mm)
GROUP
II B
Non-conductive dusts
GROUP
II C
Conductive dusts
■
Explosion Proof Specifications
■
Telephone lines rated power
•
Rated power when telephone lines are not in use: 45VDC - 55VDC
•
Rated power when telephone rings : 95VDC - 130VDC(Ring Ring signal sound)
Summary of Contents for SESA-TI