3
• Machine holes on the mounting surface refer-
ring to the diagram below. (S125S only)
■
Mounting Hole Specifications
PCD 85
3-Ø6 HOLES
S125S
Mounting Hole Specifications/ Xenon Bulb Replacement lnstructions
Mounting Accessories (Sold Separately)
Dimensions
S125S
SWP125
SWM125
• Please refer to the dimensions below for installation of mounting brackets
Ø22
Ø22
Ø10 CABLE ENTRY
6-Ø5.5 HOLES
360°/ 3-
Ø5.5 HOLES
6-Ø5.5 HOLES
4-Ø5.5 HOLES
Ø10 CABLE ENTRY
4-Ø5.5 HOLES
360°/ 3-
Ø5.5 HOLES
70
94
69
11.5
26.5
117
PCD5
0
PCD85
PCD60~70
70
90
65
115
11.5
26.5
PCD50
PCD85
PCD60~70
■
Xenon Bulb Replacement instructions
•
Please wait at least 30 mimutes after turning off the power
before replacing the xenon bulb.
• Please pull out the entire xenon bulb structure
①
to disas-
semble.
• For xenon bulb assembly, please ensure the connector portion
of the xenon bulb structure matches the pin location
②.
①
②
Disassemble
bulb
Assemble bulb
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP54.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP54), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it’s operation.
• For further information, please visit our website (www.qlight.com).