background image

ww w.qlight.com

 
 

 

▪  Please  make  a  hole  by  a  drill  where  you  need  to  attach  our 

product and refer to below picture for a hole size. (Make sure 
PCD from external view drawing.) 

▪  S100S  :  Fix  the  product  by  using  nuts(M4-3EA)  originally 

equipped on mounting bolt on bottom of the product. 

▪  S125S  :  Fix  the  product  by  using  nuts(M5-3EA)  originally 

equipped on mounting bolt on bottom of the product. 

 

 

 

1)  ※  Warning!   

Must  turn  off  power  supply  and  change  bulb  after  1  minute  at 

least. 

▪  Xenon  lamp  emits  superheat  when  working.  Please  be  aware 

you  should  not  touch  bulb  before  lowering  its  heat  prevent 

from a burn. 

▪  Xenon  lamp  work  with  a  high  voltage,  if  you  touch  a 

assembling board or lamp without power-off, you may receive 

an electric shock.   

 

2) Lens Removal 

Remove  lens  by  turning  it  counterclockwise.  Please  make  sure 

the lamp on the assembling board and Steady/Flashing selection 

switch.   

 

3) Change Lamp 

▪  Our  company’s  xenon  lamp  (1)  is  made  as  a  connector  type 

lamp. If you pull out with a small strength, it can be separated 

easily.       

▪  Please fit the lamp by checking a connector pin location (2) as 

below picture. 

Lamp removal                        Lamp fitting 

 

4) Lens Assembling   

Assemble the product in reverse order of separating. 

 

▪ If using voltage is seriously higher or lower than rated voltage, it   

can reduce the self-life of the product or can cause a problem   

on product operating. Make sure the using voltage does not   

/-5% of the rated voltage. 

▪ If lens or body of the product is contaminated by chemicals such   

as thinner, benzene, the product can be damaged, discolored 

or deformed. Please be careful.   

▪ Do not give strong impact to the product. It can be a reason of   

wire disconnection or short circuit. 

▪ Do not strongly pull the wire out from the product. It can cause a   

disorder. 

 

Situation 

Main reason 

Solution 

Lamp non-working 

Damage on Lamp 

Change lamp 

Lamp connector 
badness 

Re-connecting 

lamp 

connector 

No Power Supply 

Making sure power 
supply 

Strobe working 
irregularly. 

Supplying voltage   
lower than rated   
voltage 

Making sure using   
voltage 

 

 
 

 

 

 

 

 

(S100S) 

 

 

 
 

 

(S125S) 

 

Bulb change 

 