background image

3

2-Ø9 HOELS or

2-M8 TAPS

QWCD35

T-TI : PCD

 150-163

QWCD50

T-TI : PCD

 186-202

Parts Definition / Installation/ 

Sound Selection

Installation

■Sound Selection - Using Internal Switch (Built-in Sound Type)

• First, make taps or holes that match the product  

  mounting bolts locations on the mounting surface

.

• The mounting hole of this product is 9mm in diameter 

  (long hole).

• If the tap is machined, fasten the bolt through the 

  mounting hole of the product.
• When machining a hole, insert the bolt through the 

  product, insert it into the hole, and tighten the nut from 

  the opposite side of the mounting surface.
• 

Install a flat washer and a spring washer to the bolt if 

  the product can experience severe vibration and 

  shock. 

2-Ø9 HOELS or

2-M8 TAPS

QWCD35

T-TI : PCD

 150-163

QWCD50

T-TI : PCD

 186-202

■ Tap Machining

■ Hole Machining

Parts Definition

QWCD35-TI / QWCD50-TI

Body(PC+ABS)

PCB

Cable gland

Horn(PC)

Resonator(PC)

• For built-in sound type, use ‘Sound Channel Selection Switch’ located inside the product in  

  order to select the type of sound. (For sound configuration chart, please refer to page 5)

1   2   3   4   5

ON

Telephone lines rated power

• 

Rated power when telephone lines are not in use: 45VDC - 55VDC

• 

Rated power when telephone rings : 95VDC - 130VDC(Ring Ring signal sound)

Summary of Contents for QWCD35-TI

Page 1: ...use malfunction or damage to the product fire and electric shock Precautions for Correct Use Failure to follow the proper instructions may cause damage to property the product or malfunction of the pr...

Page 2: ...minal box equipped type Built in standard sound DC12V 24V 17W Max 1 340A Binary Input 31Ch Warning Sounds Max 115dB Based on WS Ch31 1 30kg R Red A Amber G Green B Blue AC110V 220V 41W Max 0 370A 1 35...

Page 3: ...and tighten the nut from the opposite side of the mounting surface Install a flat washer and a spring washer to the bolt if the product can experience severe vibration and shock 2 9 HOELS or 2 M8 TAP...

Page 4: ...CB is powered on and beacon sounder will be operated Beacon sounder will be stopped when an operator receives a phone call Telephone Line Please wire the unit in accordance with a wiring diagram below...

Page 5: ...ng 7 0 0 1 1 1 Pi o Pi o 8 0 1 0 0 0 Phone Ring 9 0 1 0 0 1 Pi buzzer 10 0 1 0 1 0 Pi pi pi short 11 0 1 0 1 1 Di o Di o 2 tones buzzer 12 0 1 1 0 0 Oit Oit warning sound 13 0 1 1 0 1 Slow Ambulance P...

Page 6: ...ject it to excessive dust or water other than the designated IP protection ratings indicated IP66 it may cause malfunction or damage to the product After installing the cable tighten the cable entry a...

Page 7: ...ing the sky Sounder part shall not be facing the sky BEACON SIGNALING LIGHT Power cord inlet part shall not be facing the sky Power cord inlet part shall not be facing the sky SIGNAL TOWER LIGHTS HEAV...

Page 8: ...hina Tel 86 21 6651 7100 Fax 86 21 6315 3929 China Factory Site 2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 8384...

Reviews: