3

Parts Definition/ Bracket Adjustment

■ 

Parts Definition

• In case angle adjustment is needed after installation, please loosen the 

  fixing bolt of two brackets 

 completely and remove them.

• Securing the bracket bushings 

 using spanner, loosen the bracket 

  fixing nuts 

 slightly and adjust the angle as desired. 

• Once the angle is adjusted as desired, please secure the bracket fixing 

  bolt 

 aligning with guide rail and tighten the bracket fixing nut 

③.

• M12 connector type product with a cable entry is available 

  upon request.

■  

Bracket Adjustment

■ 

M12 Connector Type Model

Lens(Tempered glass)

Housing(AI)

Bracket(SPC-1)

M12 Connector

VIEW “A”

VIEW “A”

Installation Environment and Protection Rating

 

This product is designed for use with protection rating of IP67/IP69K.

 

If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating 

  indicated(IP67/IP69K), it may cause malfunction or damage to the product.

 

For further information, please visit our website(www.qlight.com).

Installation/ Mounting Hole Specifications

MODEL

QMFLN - 200
QMFLN - 300
QMFLN - 400
QMFLN - 500
QMFLN - 600

A

210
310
420
520
620

4-Ø7 HOLES

20

A

• First, machine taps or holes on the mounting surface 

.

• The mounting hole of this product is 7mm in diameter(long hole).

• When machining taps, fasten the bolt through the mounting hole of the product.

• When machining holes, insert the bolt through the hole of the product, 

  and tighten the nut from the opposite side of the mounting surface.

• Install flat washer and spring washer when fastening bolt and nut.

• 

Machine holes on the mounting surface referring to the diagram below.

■  

I

nstallation

■ 

Mounting Hole Specifications