background image

LEVEL 3

*

(PRESS)

(PRESS)

Temperature Tracking Monitor

ON / OFF

Control Calibration Adjust

Set Temperature Lock

OFF/ON

(oFF)

(-2.5 to +2.5)

)

Select Display Resolution

1 / 0.1

Select 

o

C / 

o

F

 NONE

,

o

C, 

o

F, Bar, PSi, 

Ph 

*

(PRESS)

(PRESS)

(PRESS)

LEVEL 2

LEVEL 1

MENU ENTRY

POINT

(C)

Functions Menu

Guide

IMPORTANT NOTE: The grey-shaded control functions within the menu levels are factory 
tuned and set for the optimum performance and the safe operation for your model 
incubator. Care should be taken when navigating or changing 

user applicable

 

settings

 

so as not to alter these factory settings.  Factory settings for each function are listed within 
the parentheses "(   )" on each prompt tab above. Use as a trouble-shooting reference.

PAGE 3

Access the menu levels for the following functions: (user applicable functions and
their menu locations are high-lighted in white in the Functions Menu Guide below).

~   Change control to read in C or F temperature units.(           in level 2)
~   Change to whole degree or 1/10th degree display resolution.(          in level 2)
~   Run or Read temperature tracking.(          or           in level 3)
~   Lock Temperature setting against inadvertent adjustment.(          in level 1)
~   Calibrate control temperature to an external standard.(          in level 3)

To access the control's function menu:

Press and hold both arrow keys for 3 seconds then release when the "tune" function prompt is displayed from 
within LEVEL 1 (see "menu entry point" at the bottom of the Menu Guide below). When in the function menu 
the LED display will alternate the function prompt with the function setting when keys are released. 

(FIG 4)

  

To navigate within the functions menu:

Use up and down arrow keys individually to move "right" or "left" within a level. Press and hold the star key 
and then the up or down arrow keys to move "up" or "down" respectively through levels 1, 2 and 3 (Note: you 
must be at           prompt to move up or down levels). 

To change a function setting:

Once at the desired level function prompt, press and hold the star key and press the up or down key to select 
or change the function setting. Release star key to set the function. Press the up and down keys together to 
return to temperature display or the control will auto-return in 60 seconds. 

FIG. 4

FUNCTION PROMPT

FUNCTION SETTING

Alternating 
Display

Control Menu Functions 

(62.0) for 1

40 Series, (94) for 180 Series

Reviews: